Interface modules DOLD

Показано товаров: 10 из 15
Артикул: 1324802
• According to DIN EN 61810
• With forcibly guided contacts according to IEC 61810-3
• Pluggable safety relay
• Low rated power consumption: 0.8 W
• Max. 2 output contacts
• Contact material: AgNi with fine gold
• High thermal current up to Ith = 5 A
• Large temperature range: - 40 ... + 85 °C
• As option with free-wheel diode or varistor between A1/A2
• As option with AgSnO2 or AgNi with hard gold
• Width: 15.8 mm
Артикул: 1324801
• According to IEC/EN 60255, IEC/EN 61810-1
• With positively guided contacts according to EN 50 205
• Low nominal consumption: 0.75 W / 1 W / 1.25 W
• Max. 8 output contacts
• Contact material AgNi + 0.2 μm Au
• High thermal current Ith = 8 A
• Large temperature range: -25 ... +55°C
• Safety relay soldered on board
• Optionally AgNi + 5 μm Au or AgSnO + 0.2 μm Au
• Optionally with free-wheeling diode across A1/A2
• Optionally plug-in type
HA 5601 on socket HL 3094/10_
HA 5602 on socket HO 3094/10_
HA 5603on socket HO 3095/10_
• HL: 38 mm width
HO: 73.3 mm width
Артикул: 1324800
• According to IEC/EN 60255, IEC/EN 61810-1
• With positively guided contacts according to EN 50 205
• Low nominal consumption: 0.75 W / 1 W / 1.25 W
• Max. 8 output contacts
• Contact material AgNi + 0.2 μm Au
• High thermal current Ith = 8 A
• Large temperature range: -25 ... +55°C
• Safety relay soldered on board
• Optionally AgNi + 5 μm Au or AgSnO + 0.2 μm Au
• Optionally with free-wheeling diode across A1/A2
• Optionally plug-in type
HA 5601 on socket HL 3094/10_
HA 5602 on socket HO 3094/10_
HA 5603on socket HO 3095/10_
• HL: 38 mm width
HO: 73.3 mm width
Артикул: 1324799
• According to IEC/EN 60255, IEC/EN 61810-1
• With positively guided contacts according to EN 50 205
• Low nominal consumption: 0.75 W / 1 W / 1.25 W
• Max. 8 output contacts
• Contact material AgNi + 0.2 μm Au
• High thermal current Ith = 8 A
• Large temperature range: -25 ... +55°C
• Safety relay soldered on board
• Optionally AgNi + 5 μm Au or AgSnO + 0.2 μm Au
• Optionally with free-wheeling diode across A1/A2
• Optionally plug-in type
HA 5601 on socket HL 3094/10_
HA 5602 on socket HO 3094/10_
HA 5603on socket HO 3095/10_
• HL: 38 mm width
HO: 73.3 mm width
Артикул: 1324798
• According to IEC/EN 61810-1, IEC 60664-1,
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in PCB safety relay
• With polarity protected diode
• Optionally with free-wheeling diode across relay coil
• With LED indicator
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• Clearance and creepage distance between NC and NO contact > 10 mm
• Width 22,5 mm
Артикул: 1324797
• According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in or plug-in PCB safety relay consisting of:
- plug in socket HC 3096N and safety relay OA 5611
- plug in socket HL 3096N and safety relay OA 5612
• With polarity protected diode
• Optionally with free-wheeling diode across A1+ and A2
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• HC 3096N: width 18 mm
HL 3096N: width 36 mm
Артикул: 1324796
• According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in or plug-in PCB safety relay consisting of:
- plug in socket HC 3096N and safety relay OA 5611
- plug in socket HL 3096N and safety relay OA 5612
• With polarity protected diode
• Optionally with free-wheeling diode across A1+ and A2
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• HC 3096N: width 18 mm
HL 3096N: width 36 mm
Артикул: 1324795
• According to IEC/EN 60 255, IEC/EN 61 810-1
• Forcibly guided contacts according to IEC 61810-3
• Max. 6 output contacts
• High thermal current Ith = 8 A
• LED for operating state
• Devices available in 2 enclosure versions:
IP 3078: depth 61 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SP 3078: depth 100 mm, with terminals at the top
• Width 70 mm
Артикул: 1324794
• According to IEC/EN 60 255, IEC/EN 61 810-1
• Forcibly guided contacts according to IEC 61810-3
• Max. 6 output contacts
• High thermal current Ith = 8 A
• LED for operating state
• Devices available in 2 enclosure versions:
IP 3078: depth 61 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SP 3078: depth 100 mm, with terminals at the top
• Width 70 mm
Артикул: 1324793
• According to IEC/EN 61 810-1
• With input protection circuit against voltage peaks
• Forcibly guided contacts according to IEC 61810-3
• Ith max. 8 A or 2 x 5 A
• Functional display by LED
• Optionally 2 NO or 2 changeover contacts or 1 NO and 1 NC
• IK 3079/103: with forcibly guided contacts according to ZH/457
• 17.5 mm width