Fault annunciators DOLD

Показано товаров: 10 из 26
Артикул: 1325092
• According to IEC/EN 60 255, DIN VDE 0435-303
• Common alarm annunciator for 12 signals
• 1 relay for common signal and horn
• Inputs up to AC/DC 230 V
• 1 connection for acknowledgement button of horn and lamp test
• Width: 45 mm
Артикул: 1325094
• According to DIN 19235
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs  selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm

Extension unit IL 5991, SL 5991:
• 4 inputs with LED on control unit
Артикул: 1325098
Common Alarm Annunciator RP 5990, RP 5991
• Fast localisation of failures and their causes
• Reduction of standstill times in production
• Common alarm annunciator with manual or auto reset of faults
• Expandable from 8 to 88 fault signals
• Open or closed circuit operation settable with rotational switch on base unit and with link X1/X2 on extension units
• Adjustable on delay for input signals 0 to 10 sec
• Reset buttons for audible alarm and common alarm on front side
• Connection for external reset of audible alarm
• Galvanic separation to bus RS485 (optional)
• Accessories: buzzer RK 8832, display unit EH 5990, EH 5991
• Width: 70 mm

• Base Module RP 5990:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm and common alarm
- Connection for external reset of audible alarm
• Extension Module RP 5991:
- 8 fault signal inputs with indicator LED on the unit
- As option one relay output each for audible alarm and common alarm
- As option reset buttons for audible alarm and common alarm
Артикул: 1325114
• Permanent sound, pitch fixed
• optionally with switchable interval- / permanent sound
• Devices available in 2 enclosure versions:
- I- and-version, e.g. IK _ _ _ _ with depth 61 mm, with terminals at the bottom for installation systems and
industrial distribution systems according to DIN 43 880, - S-version, e.g. SK _ _ _ _ with depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width: 17,5 mm
Артикул: 1325103
Display unit EH 5994, EH 5995
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP 64
• Enclosure for flush mounting 96 x 96 mm
• Display unit EH 5994:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm, common alarm and alarm signal
• Display unit EH 5995:
- 8 fault signal LEDs on the unit
- Without reset buttons
Артикул: 1325113
• For max. 11 indicator lamps
• Width 22.5 mm
Артикул: 1325102
Display Unit EH 5990, EH 5991
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP64
• Enclosure for flush mounting 96 x 96 mm
• Display Unit EH 5990:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm and common alarm
• Display Unit EH 5991:
- 8 fault signal LEDs on the unit
- Without reset buttons
Артикул: 1325112
• For max. 11 indicator lamps
• Width 22.5 mm
Артикул: 1325096
• According to DIN 19235
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs  selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm

Extension unit IL 5991, SL 5991:
• 4 inputs with LED on control unit
Артикул: 1325111
• According to directive 1999/5/EC (RTTE) for radio equipment and telecommunications terminal equipment
• 4 digital inputs and 4 relay outputs
• Variant RP 5812/001 with 2 digital and 2 analogue inputs and 1 analogue - and 2 relay outputs
• Auxiliary voltage DC 24 V
• DC 24 V digital inputs
• Automatic SMS messages for status changes
• Quad-Band GSM-Module for 850, 900, 1800 and 1900 MHz (GSM = Global System for Mobile)
• Pin protection of SIM card
• Caller password protection against unauthorised access
• User Dialogue language for: German, English or French
• Configurable authorization levels for up to 16 users
• Assignment of different I/O’s to different users
• Automatic sending of SMS when digital inputs change state I.e. come on or go off or both (on rising edge or falling edge)
• Automatic sending of SMS when analogue inputs
- exceed preset lower and upper limits or
- when signal is within the preset window
- and when the signal returns to good state
• Adjustable
- Hysteresis for analogue inputs
- Time delay for each input
- Repeat time for SMS-transmitting
- Time delay for output status after starting the unit
- Time delay for activation of the output
• SMS for device status to the system administrators
• SMS-counter to monitor the remaining account
• No interruption of operation after Voltage failure due to integrated  Li-Ion battery backup 24Hours
• Compact width: 70 mm