General Purpose safety controllers (Series PROTECT SRB) Schmersal

Показано товаров: 10 из 60
Артикул: 284708
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0;
2 safety contacts, STOP 1 (adjustable 1 … 30 s)
• 3 Signalling outputs, 1 Auxiliary contact
• Optional: Short-circuit recognition, Manual reset with edge detection in fail-safe circuit, Automatic reset function
Артикул: 284707
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 3 safety contacts, STOP 0, 1 Auxiliary contact
Артикул: 284706
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 1 Signalling output
• 2 safety contacts, STOP 0
• 1 safety contact, STOP 1
• Multi-evaluation of up to 6 safety guards
• Fit for signal evaluation of outputs of safety magnetic switches
Артикул: 284705
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 1 Signalling output
• 2 safety contacts, STOP 0
• 1 safety contact, STOP 1
• Multi-evaluation of up to 6 safety guards
• Fit for signal evaluation of outputs of safety magnetic switches
Артикул: 284704
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 2 safety contacts, STOP 0
• 1 Signalling output
Артикул: 284703
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
Артикул: 284702
• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• 2 Signalling outputs
Артикул: 284701
• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• 2 Signalling outputs
Артикул: 284700
• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
Артикул: 284699
• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2