MultiRanger 200 HMI Siemens

Область применения



MultiRanger 200 HMI can be used with various materials, including, water, municipal waste, acids, woodchips, or on materials with high angles of repose. MultiRanger 200 HMI offers true dual point monitoring, digital communications with built-in Modbus RTU via RS 485, as well as compatibility with SIMATIC PDM, allowing PC configuration and set-up. MultiRanger 200 HMI features Sonic Intelligence ad-vanced echo-processing software for increased reading reliability.

MultiRanger 200 HMI will monitor open channel flow and features more advanced relay alarming and pump control functions as well as volume conversion.

It is compatible with chemical-resistant EchoMax transducers that are approved for hostile environments.

  • Key Applications: wet wells, flumes/weirs, bar screen control, hoppers, chemical storage, liquid storage, crusher bins, dry solids storage

Обзор



MultiRanger 200 HMI is a versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries.

Дизайн



The MultiRanger 200 HMI is available in wall or panel mounting options.

Чертеж



MultiRanger 200 HMI, dimensions in mm (inch)

Особенности


  • Easy to use HMI display with local four-button programming, menu-driven parameters, and Wizard support for key applications
  • English, German, French, Spanish, Chinese, Italian, Portuguese, and Russian texts on the HMI
  • Removable terminal blocks for ease of wiring
  • Digital input for back-up level override from point level device
  • Communication using built-in Modbus RTU via RS 485
  • Compatible with SmartLinx system and SIMATIC PDM configuration software
  • Single or dual point level monitoring
  • Auto False-Echo Suppression for fixed obstruction avoidance
  • Differential amplifier transceiver for common mode noise reduction and improved signal-to-noise ratio
  • Level, volume, and flow measurements in open channels, differential control, extended pump control, and alarm functions
  • Wall and panel mounting options

Схема подключения



MultiRanger 200 HMI connections

Технические данные



Mode of Operation

 

Measuring principle

Ultrasonic level measurement

Measuring range

0.3 ... 15 m (1 ... 50 ft)

Measuring points

1 or 2

Input

 

Analog

0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable

Discrete

10 ... 50 V DC switching level Logical 0 ≤ 0.5 V DC Logical 1 = 10 ... 50 V DC Max. 3 mA

Output

 

EchoMax transducer

44 kHz

Ultrasonic transducer

Compatible transducers: ST-H and EchoMax series XPS-10, XPS-15/15F, and XRS-5

Relays

Rating 5 A at 250 V AC, non-inductive

mA output

0 ... 20 mA or 4 ... 20 mA

  • Max. load

750 Ω, isolated

  • Resolution

0.1 % of range

Accuracy

 

Error in measurement

0.25 % of range or 6 mm (0.24 inch), whichever is greater

Resolution

0.1 % of measuring range1)or 2 mm (0.08 inch), whichever is greater

Temperature compensation

  • -50 ... +150 °C (-58 ... +302 °F)
  • Integral temperature sensor
  • External TS-3 temperature sensor (optional)
  • Programmable fixed temperature values

Rated operating conditions

 

Installation conditions

 
  • Location

Indoor/outdoor

  • Installation category

II

  • Pollution degree

4

Ambient conditions

 
  • Ambient temperature (housing)

-20 ... +50 °C (-4 ... +122 °F)

Design

 

Weight

 
  • Wall mount

1.22 kg (2.68 lb)

  • Panel mount

1.35 kg (2.97 lb)

Material (enclosure)

Polycarbonate

Degree of protection (enclosure)

 
  • Wall mount

IP65/Type 4X/NEMA 4X

  • Panel mount

IP54/Type 3/NEMA 3

Electrical connection

 
  • Transducer and mA output signal

2-core copper conductor, twisted, shielded, 0.5 ... 0.75 mm² (22 ... 18 AWG), Belden 8760 or equivalent is acceptable

  • Max. separation between transducer and transceiver

365 m (1 200 ft)

Displays and controls

60 x 40 mm (2.36 x 1.57 inch) LCD 240 x 160 pixels resolution

Power supply

 

AC version

100 ... 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W)

DC version

12 ... 30 V DC (20 W)

Certificates and approvals

  • CE, RCM2)
  • FM, CSAUS/C, UL
  • CSA Class I, Div. 2, Groups A, B, C and D, Class II, Div. 2, Groups F and G, Class III (wall mount only)

Communication

  • RS 232 with Modbus RTU or ASCII via RJ-11 connector
  • RS 485 with Modbus RTU or ASCII via terminal strips
  • Optional: SmartLinx cards for
    • PROFIBUS DPV1
    • DeviceNet


1) Program range is defined as the empty distance to the face of the transducer plus any range extension

2) EMC performance available on request