Power Output Module (POM) Siemens

Обзор



The power output modules (POMs) are an essential component of the SIPLUS HCS4200 heating control system.
Up to 12 power output modules can be operated on one CIM.

POM4220 low-end power output module:

  • 16 outputs for switching ohmic loads.
  • A current of up to 6.3 A can be used per output channel.
  • Module simply slides into the rack.
  • And is secured by one screw at the bottom and another screw at the top.

Дизайн


  • The heat emitters are connected via two 8-pole connectors (mating connectors are included in the scope of delivery)
  • Line feed (Lx/N/Ly) at the front by means of 3-pole connector (mating connector is included in the scope of delivery)
  • 1 fuse per output for the heat emitter supply circuit, in open fuse holders
  • Internal serial interface on the rear
  • 3 diagnostic LEDs for indicating module faults
  • 16 diagnostic LEDs for indicating channel faults

Функции



Power switching elements

  • Power triacs
  • Protection of triacs and opto-triacs against overvoltages by Transil diodes
  • Transfer of the diagnostics information to the central interface module (CIM)

Control modes

  • Half-wave control:
    Here the channel is controlled depending on the parameterized manipulated variable for each zero point. The controller outputs are set in values from 0 to 100 %.

Output power

  • 16 power channels of 230 V each (8 outputs per phase)
  • Switching power per output: Max. 1449 W at 230 V
  • Switching capacity per power output module: Max. 16100 W at 230 V

Ventilation

  • A fan module can be optionally mounted at the top of the rack so that 4 POMs can be ventilated and controlled dependent on the internal temperature.

Temperature monitoring

  • An NTC thermistor is installed in the device to monitor the internal temperature. An alarm threshold is defined for the internal temperature. The following reactions are triggered when the threshold is overshot:
  • Signal to the higher-level controller.
  • The channels are deactivated - regardless of which channel response was configured for error situations.

Diagnostic options

Implicit diagnostics functions are provided as standard to detect the following faults (diagnostics cycle does not affect the heating power):

  • Leading fuse defective / triac at high resistance (exception: setpoint 0%)
  • Triac failure (exception: setpoint 100%)
  • Heating element cable is defective (short-circuit and interruption)
  • Load defective (short-circuit and interruption)

Технические данные



Order number

 

6BK1942-2AA00-0AA0

product brand name

 

SIPLUS

Product designation

 

HCS POM4220 Lowend

General technical data:

 

 

Type of load

 

Ohmic load

Equipment marking acc. to DIN EN 81346-2

 

Q

Supply voltage:

 

 

Type of voltage of the supply voltage

 

AC

Supply voltage at AC Rated value

V

230

Relative negative tolerance of the supply voltage

%

10

Relative positive tolerance of the supply voltage

%

10

Supply voltage frequency 1 Rated value

Hz

50

Supply voltage frequency 2 Rated value

Hz

60

Relative symmetrical tolerance of the supply voltage frequency

%

5

Power capacity

 

 

  • of the module with star connection at 40 °C with fan maximum

kW

16.1

  • of the module with star connection at 40 °C without fan maximum

kW

7.3

  • maximum permissible

kW

16.1

Switching capacity current per phase maximum

A

35

Design of the electrical isolation

 

Optocoupler and/or protective impedance between main circuit and PELV

Recovery time after power failure typical

s

1

Type of electrical connection for supply voltage

 

Connector, 3-pin

Type of connectable conductor cross-section

 

 

  • for supply voltage finely stranded with core end processing

 

1x (0,25 ... 6 mm²)

  • for AWG conductors for supply voltage

 

24 ... 8

Power Electronics:

 

 

Control version of heat emitters

 

Half-wave control

Number of outputs for heating power

 

16

Number of heat emitters per output maximum

 

1

Output voltage at output for heating power

V

230

Power capacity per output

 

100 ... 1 449

Output current at output for heating power Rated value

A

6.3

Design of short-circuit protection for heating power per output

 

Safety fuse 6.3 A

Melting I2t value

A²·s

57

Design of the overvoltage protection

 

Transil Diode

Galvanic isolation between the outputs

 

No

Type of electrical connection at output for heating and fan

 

Connector, 8-pole

Type of connectable conductor cross-section

 

 

  • for heating and fan solid

 

1x (0.2 ... 10 mm²)

  • for heating and fan finely stranded with core end processing

 

1x (0,25 ... 6 mm²)

  • for AWG conductors stranded

 

24 ... 8

Communication:

 

 

Design of the interface

 

system interface

Display:

 

 

Number of status displays

 

19

Display version as status display by LED

 

LED green = ready, LED yellow = heating on/off, LED red = error display, LED red = error for each channel

Auxiliary circuit:

 

 

Design of the power supply

 

Power supply via rack

Active power consumption maximum

W

1

Protective and monitoring functions:

 

 

Product function Temperature monitoring

 

Yes

Type of the temperature monitoring

 

NTC thermistor

Diagnostics function

 

Voltage diagnostics

  • Tripped fuse

 

Yes

  • Cable break

 

Yes

  • Heat emitter failure

 

Yes

Mechanical data:

 

 

mounting position

 

vertical

Mounting type

 

Screw mounting to rack

Type of ventilation

 

Self ventilation or forced ventilation

Vibration resistance

 

 

  • during operation acc. to IEC 60068-2-6

 

10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1g

  • during storage acc. to IEC 60068-2-6

 

5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1g

Shock resistance

 

 

  • acc. to IEC 60068-2-29

 

25 g / 6 ms / 1000 shocks / axis

  • acc. to IEC 60068-2-27

 

15g / 11 ms / 3 shocks / axis

Protection class IP

 

IP20

Depth

mm

281

Height

mm

285

Width

mm

36

Electromagnetic compatibility:

 

 

EMC emitted interference

 

Limit value in accordance with IEC 61000-6-4:2007 + A1:2011

Conducted interference due to burst acc. to IEC 61000-4-4

 

2 kV power supply lines, 2 kV load lines

Conducted interference due to surge acc. to IEC 61000-4-5

 

Supply and load lines: 1 kV symmetric, 2 kV unsymmetric PROFINET cables: 1 kV unsymmetric

Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6

 

10 V (0.15 ... 80 MHz)

Field-bound parasitic coupling acc. to IEC 61000-4-3

 

10 V/m (80 ... 1000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz)

Electrostatic discharge acc. to IEC 61000-4-2

 

4 kV contact discharging, 8 kV air discharging

Overvoltage category

 

III

Ambient conditions:

 

 

Ambient temperature

 

 

  • during operation

 

0 ... 55

  • during storage

 

-25 ... +70

  • during transport

 

-25 ... +70

Air pressure

 

 

  • during operation

 

860 ... 1 080

  • during storage

 

660 ... 1 080

Degree of pollution

 

2

Installation altitude at height above sea level maximum

m

2 000

Relative humidity

 

 

  • at 25 °C during operation maximum

%

95

  • at 50 °C during operation maximum

%

50

  • at 50 °C during operation maximum Note

 

95% at 25 °C, decreasing linearly to 50% at 50 °C


Дополнительно



The following accessories are available for the POM4220 low-end power output module:

  • Connector set, 3-pole (block with 10 connectors) for connecting the line infeed
  • Connector set 8-pole (block with 10 connectors) for connecting the heat emitters
  • Fuse 6.3 A/250 V (set with 50 fuses) as spare part