CPU 412 Siemens

Область применения



The CPU 412-1 is the low-cost entry into the medium performance range. It can be used in smaller systems with limited I/O configuration. The combined MPI/DP interface also enables operation of a PROFIBUS DP line.

The CPU 412-2 is the CPU for applications in the mid-performance range with 2 PROFIBUS DP master systems.

For networking within a PROFINET network, the CPU 412-2 PN is available.

Обзор


  • The low-cost starter solution for the medium performance range
  • Can be used in small and medium-sized systems with requirements of the medium performance range

Дизайн



The CPU 412-1, CPU 412-2 and CPU 412-2 PN are equipped with the following:

  • Powerful processor:
    The CPUs achieve command runtimes down to 0.75 µs per binary instruction.
  • CPU 412-1: 288 KB RAM (of which 144 KB each for program and data);
    CPU 412-2: 512 KB RAM (of which 256 KB each for program and data);
    CPU 412-2: 1 MB RAM (of which 512 KB each for program and data);
    fast RAM for parts of the user program relevant to execution.
  • Flexible expansion:
    Up to 65536 digital and 4096 analog inputs/outputs.
  • Multi-point interface MPI:
    With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 16 connections to stations of the communication bus (C bus) and the MPI.
  • Mode selector switch:
    Designed as toggle switch.
  • Diagnostics buffer:
    The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
  • Real-time clock:
    The date and time are appended to diagnostic messages of the CPUs.
  • Memory card:
    For expansion of the integrated load memory. The information in the load memory comprises S7-400 parameterization data in addition to the program and therefore requires twice as much memory space. The result is:
    • The integral load memory is sufficiently large, so a memory card is often not required.

The CPU 412-2 also features:

  • PROFIBUS DP interface and combined MPI/DP interface:
    The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user''s point of view, the distributed I/O is treated as central I/O (same configuring, addressing, and programming).
  • Mixed configuration:
    SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.

Функции


  • Block protection:
    A password concept also protects the user program from unauthorized access
  • Integrated HMI services:
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
  • Integrated communication functions:
    • PG/OP communication
    • Global data communication
    • S7 standard communication
    • S7 communication

Programmable properties

The STEP 7 tool "Hardware configuration" can be used to parameterize the properties and response of the S7-400 including the CPUs, e.g.

  • Multipoint interface MPI:
    • Definition of node addresses
    • Startup/cycle behavior
    • Stipulation of the maximum cycle time and communication load
  • Address allocation:
    Addressing of I/O modules
  • Retentive area:
    Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
  • Size of the process image, local data
  • Length of the diagnostics buffer
  • Protection level:
    Definition of access authorizations to program and data
  • System diagnostics:
    Definition of the handling and scope of diagnostics messages
  • Timed interrupts:
    Setting of periodicity

Display and information functions

  • Status and fault indicators:
    LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
  • Test functions:
    The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
  • Information functions:
    The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

Технические данные



Order number

6ES7412-1XJ05-0AB0

6ES7412-2XJ05-0AB0

6ES7412-2EK07-0AB0

CPU412-1, MPI/DP, 288 KB

CPU412-2, MPI/DP, 512 KB

General information

 

 

 

Product type designation

CPU 412-1

CPU 412-2

CPU 412-2 PN

Engineering with

 

 

 

  • Programming package

STEP7 V 5.3 SP2 or higher with HW update

STEP7 V 5.3 SP2 or higher with HW update

STEP 7 V5.5 or higher with HSP 262

Supply voltage

 

 

 

Rated value (DC)

  • 24 V DC

No; Power supply via system power supply

No; Power supply via system power supply

No; Power supply via system power supply

Power loss

 

 

 

Power loss, typ.

2.5 W

4.5 W

5.5 W

Memory

 

 

 

Work memory

 

 

 

  • integrated

288 kbyte

512 kbyte

1 Mbyte

  • integrated (for program)

144 kbyte

256 kbyte

512 kbyte

  • integrated (for data)

144 kbyte

256 kbyte

512 kbyte

Load memory

 

 

 

  • expandable FEPROM, max.

64 Mbyte

64 Mbyte

64 Mbyte

  • integrated RAM, max.

512 kbyte

512 kbyte

512 kbyte

  • expandable RAM, max.

64 Mbyte

64 Mbyte

64 Mbyte

CPU processing times

 

 

 

for bit operations, typ.

75 ns

75 ns

31.25 ns

for word operations, typ.

75 ns

75 ns

31.25 ns

for fixed point arithmetic, typ.

75 ns

75 ns

31.25 ns

for floating point arithmetic, typ.

225 ns

225 ns

62.5 ns

Counters, timers and their retentivity

 

 

 

S7 counter

 

 

 

  • Number

2 048

2 048

2 048

IEC counter

 

 

 

  • present

Yes

Yes

Yes

S7 times

 

 

 

  • Number

2 048

2 048

2 048

IEC timer

 

 

 

  • present

Yes

Yes

Yes

Data areas and their retentivity

 

 

 

Flag

 

 

 

  • Number, max.

4 kbyte; Size of bit memory address area

4 kbyte; Size of bit memory address area

4 kbyte; Size of bit memory address area

Address area

 

 

 

I/O address area

 

 

 

  • Inputs

4 kbyte

4 kbyte

4 kbyte

  • Outputs

4 kbyte

4 kbyte

4 kbyte

Process image

 

 

 

  • Inputs, adjustable

4 kbyte

4 kbyte

4 kbyte

  • Outputs, adjustable

4 kbyte

4 kbyte

4 kbyte

Hardware configuration

 

 

 

Slots

 

 

 

  • required slots

1

1

1

Time of day

 

 

 

Clock

 

 

 

  • Hardware clock (real-time clock)

Yes

Yes

Yes

Operating hours counter

 

 

 

  • Number

16

16

16

Interfaces

 

 

 

Interfaces/bus type

1 x MPI/PROFIBUS DP

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP

1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports)

Number of RS 485 interfaces

1; Combined MPI / PROFIBUS DP

2; Combined MPI / PROFIBUS DP and PROFIBUS DP

1; Combined MPI / PROFIBUS DP

1. Interface

 

 

 

Interface type

Integrated

Integrated

Integrated

Physics

RS 485 / PROFIBUS + MPI

RS 485 / PROFIBUS + MPI

RS 485 / PROFIBUS + MPI

Functionality

 

 

 

  • MPI

Yes

Yes

Yes

  • DP master

Yes

Yes

Yes

  • DP slave

Yes

Yes

Yes

DP master

 

 

 

  • Number of DP slaves, max.

32

32

32

2. Interface

 

 

 

Interface type

Integrated

PROFINET

Physics

RS 485 / PROFIBUS

Ethernet RJ45

Number of ports

2

Functionality

 

 

 

  • DP master

Yes

No

  • DP slave

Yes

No

  • PROFINET IO Controller

Yes

  • PROFINET IO Device

Yes

  • PROFINET CBA

Yes

DP master

 

 

 

  • Number of DP slaves, max.

64

PROFINET IO Controller

 

 

 

  • Number of connectable IO Devices for RT, max.

256

  • Number of IO Devices with IRT and the option "high flexibility"

256

  • Number of IO Devices with IRT and the option "high performance", max.

64

Isochronous mode

 

 

 

Isochronous operation (application synchronized up to terminal)

Yes; For PROFIBUS only

Yes; For PROFIBUS only

Yes; Via PROFIBUS DP or PROFINET interface

Communication functions

 

 

 

PG/OP communication

Yes

Yes

Yes

Data record routing

Yes

Yes

Yes

Global data communication

 

 

 

  • supported

Yes

Yes

Yes

S7 basic communication

 

 

 

  • supported

Yes

Yes

Yes

S7 communication

 

 

 

  • supported

Yes

Yes

Yes

S5 compatible communication

 

 

 

  • supported

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Standard communication (FMS)

 

 

 

  • supported

Yes; Via CP and loadable FB

Yes; Via CP and loadable FB

Yes; Via CP and loadable FB

Open IE communication

 

 

 

  • TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

  • Number of connections, max.

46

  • ISO-on-TCP (RFC

    Запрос коммерческого предложения

    ×


      * Поля, обязательные для заполнения.

      Сообщение отправлено

      ×

      В ближайшее время сообщение будет обработано.

      Письмо с номером обращения отправлено на Ваш почтовый ящик.

      Спасибо за то, что выбрали Первый ZIP!

      Что-то пошло не так...

      ×

      К сожалению, наша система расценила Ваше сообщение как спам.

      Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

      Приносим извинения за возможные неудобства.