CPU 414 Siemens

Область применения
CPU 414-2, CPU 414-3 and CPU 414-3 PN/DP are designed for high demands in the mid-level performance range. They meet higher demands for program scope and instruction processing speed.
The integrated PROFIBUS DP ports in the CPU 414-2 and CPU 414-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.
An additional DP master system can be connected to the CPU 414-3 and CPU 414-3 PN/DP using the IF 964-DP interface module.
For the PROFINET interface of the CPU 414-3 PN/DP, the switch functionality permits the formation of two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.
Note:
Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.
Обзор
- CPUs for high demands in the mid-level performance range
- Applicable for plants with additional demands on programming scope and processing speed
- Integrated PROFINET functions in CPU 414-3 PN/DP
Дизайн
The CPUs are equipped with the following:
- Powerful processor:
The CPUs achieve instruction execution times as low as 0.045 µs per binary instruction. - CPU 414-2: 1 MB RAM (of which 512 KB each for program and data);
CPU 414-3: 2.8 MB RAM (of which 1.4 MB each for program and data);
CPU 414-3 PN/DP: 4 MB RAM (of which 2 MB each for program and data);
fast RAM for parts of the user program relevant to execution. - Flexible expansion:
Up to 131072 digital and 81932 analog inputs/outputs. - Multi-point interface MPI:
With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 32 connections to stations of the communication bus (C bus) and the MPI - Mode selector switch:
Designed as toggle switch. - Diagnostics buffer:
The last error and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized. - Real-time clock:
The date and time are appended to diagnostic messages of the CPUs. - Memory Card:
For expansion of the integrated load memory. The information in the load memory comprises S7-400 parameterization data in addition to the program and therefore requires twice as much memory space. The result is:- The integral load memory for large programs is not sufficient, therefore a memory card is frequently required. RAM and FEPROM cards (FEPROM for retentive storage) are available.
- PROFIBUS DP interface and combined MPI/DP interface:
The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user''s point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming).
Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.
CPU 414-3 and CPU 414-3 PN/DP also include:
- Additional module slot:
An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.
CPU 414-3 PN/DP additionally includes:
- PROFINET interface with 2 ports (switch):
- PROFINET I/O, 256 IO devices connectable
- PROFINET CBA
Функции
- Block protection:
A password concept protects the user program from unauthorized access. - Integral HMI services:
The user only has to specify the source and destination of the data with HMI devices; the data are then transported cyclically and automatically by the system. - Integrated communications functions:
- PG/OP communication
- Shared data communication
- S7 standard communication
- S7 Communication
CPU 414-3 PN/DP additional:
- Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
- Distributed intelligence in Component Based Automation (CBA) on PROFINET
- Additional diagnostic options with integrated webserver
- Firmware update using network
Parameterizable attributes
The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.
- Multi-point interface MPI:
- Definition of station addresses.
- Startup/cycle behavior
- Stipulation of the maximum cycle time and communications load
- Address assignment:
Addressing of I/O modules. - Retentive ranges:
Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories. - Size of the process image, local data.
- Length of the diagnostics buffer
- Protection level:
Definition of access authorization for program and data - System diagnostics:
Definition of the handling and scope of diagnostic messages - Timed interrupts:
Setting of periodicity
CPU 414-3 PN/DP additional:
- PROFINET Interface
- Parameterization of time synchronization using NTP procedure
Indication and information functions
- Status and error indicators:
LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example. - Test functions:
The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components. - Information functions:
The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories
Технические данные
Order number | 6ES7414-2XK05-0AB0 | 6ES7414-3XM05-0AB0 | 6ES7414-3EM07-0AB0 | |
---|---|---|---|---|
CPU414-2, MPI/DP, 1 MB | CPU414-3, 2.8 MB, 3 INTERFACES | |||
General information |
|
|
| |
Product type designation | CPU 414-2 | CPU 414-3 | CPU414-3 PN/DP | |
Engineering with |
|
|
| |
| STEP7 V 5.3 SP2 or higher with HW update | STEP7 V 5.3 SP2 or higher with HW update | STEP 7 V5.5 or higher with HSP 262 | |
Supply voltage |
|
|
| |
Rated value (DC) | ||||
| No; Power supply via system power supply | No; Power supply via system power supply | No; Power supply via system power supply | |
Power loss |
|
|
| |
Power loss, typ. | 4.5 W | 5.5 W | 6.5 W | |
Memory |
|
|
| |
Work memory |
|
|
| |
| 1 Mbyte | 2.8 Mbyte | 4 Mbyte | |
| 0.5 Mbyte | 1.4 Mbyte | 2 Mbyte | |
| 0.5 Mbyte | 1.4 Mbyte | 2 Mbyte | |
Load memory |
|
|
| |
| 64 Mbyte | 64 Mbyte | 64 Mbyte | |
| 512 kbyte | 512 kbyte | 512 kbyte | |
| 64 Mbyte | 64 Mbyte | 64 Mbyte | |
CPU processing times |
|
|
| |
for bit operations, typ. | 45 ns | 45 ns | 18.75 ns | |
for word operations, typ. | 45 ns | 45 ns | 18.75 ns | |
for fixed point arithmetic, typ. | 45 ns | 45 ns | 18.75 ns | |
for floating point arithmetic, typ. | 135 ns | 135 ns | 37.5 ns | |
Counters, timers and their retentivity |
|
|
| |
S7 counter |
|
|
| |
| 2 048 | 2 048 | 2 048 | |
IEC counter |
|
|
| |
| Yes | Yes | Yes | |
S7 times |
|
|
| |
| 2 048 | 2 048 | 2 048 | |
IEC timer |
|
|
| |
| Yes | Yes | Yes | |
Data areas and their retentivity |
|
|
| |
Flag |
|
|
| |
| 8 kbyte; Size of bit memory address area | 8 kbyte; Size of bit memory address area | 8 kbyte; Size of bit memory address area | |
Address area |
|
|
| |
I/O address area |
|
|
| |
| 8 kbyte | 8 kbyte | 8 kbyte | |
| 8 kbyte | 8 kbyte | 8 kbyte | |
Process image |
|
|
| |
| 8 kbyte | 8 kbyte | 8 kbyte | |
| 8 kbyte | 8 kbyte | 8 kbyte | |
Hardware configuration |
|
|
| |
Slots |
|
|
| |
| 1 | 2 | 2 | |
Time of day |
|
|
| |
Clock |
|
|
| |
| Yes | Yes | Yes | |
Operating hours counter |
|
|
| |
| 16 | 16 | 16 | |
Interfaces |
|
|
| |
Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable) | 1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports), 1 x PROFIBUS DP (optionally pluggable) | |
Number of RS 485 interfaces | 2; Combined MPI / PROFIBUS DP and PROFIBUS DP | 2; Combined MPI / PROFIBUS DP and PROFIBUS DP | 1; Combined MPI / PROFIBUS DP | |
Number of other interfaces | 1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0) | |||
1. Interface |
|
|
| |
Interface type | Integrated | Integrated | Integrated | |
Physics | RS 485 / PROFIBUS + MPI | RS 485 / PROFIBUS + MPI | RS 485 / PROFIBUS + MPI | |
Functionality |
|
|
| |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
| Yes | Yes | Yes | |
DP master |
|
|
| |
| 32 | 32 | 32 | |
2. Interface |
|
|
| |
Interface type | Integrated | Integrated | PROFINET | |
Physics | RS 485 / PROFIBUS | RS 485 / PROFIBUS | Ethernet RJ45 | |
Number of ports | 2 | |||
Functionality |
|
|
| |
| Yes | Yes | No | |
| Yes | Yes | No | |
| Yes | |||
| Yes | |||
| Yes | |||
DP master |
|
|
| |
| 96 | 96 | ||
PROFINET IO Controller |
|
|
| |
| 256 | |||
| 256 | |||
| 64 | |||
3. Interface |
|
|
| |
Interface type | Pluggable interface module (IF), technical data as for 2nd interface | Pluggable interface module (IF) | ||
Plug-in interface modules | IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) | IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) | ||
Physics | RS 485 / PROFIBUS | RS 485 / PROFIBUS | ||
Functionality |
|
|
| |
| No | No | ||
| Yes | Yes | ||
| Yes | Yes | ||
DP master |
|
|
| |
| 96 | 96 | ||
Isochronous mode |
|
|
| |
Isochronous operation (application synchronized up to terminal) | Yes; For PROFIBUS only | Yes; For PROFIBUS only | Yes; Via PROFIBUS DP or PROFINET interface | |
Communication functions |
|
|
| |
PG/OP communication | Yes | Yes | Yes | |
Data record routing | Yes | Yes | Yes | |
Global data communication |
| {"prefetch":[{"source":"document","where":{"and":[{"href_matches":"\/*"},{"not":{"href_matches":["\/wp-*.php","\/wp-admin\/*","\/wp-content\/uploads\/*","\/wp-content\/*","\/wp-content\/plugins\/*","\/wp-content\/themes\/pzip\/*","\/*\\?(.+)"]}},{"not":{"selector_matches":"a[rel~=\"nofollow\"]"}},{"not":{"selector_matches":".no-prefetch, .no-prefetch a"}}]},"eagerness":"conservative"}]}Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |