SIPLUS S7-400 CPU 417 Siemens

Область применения



The CPU 417-4 is the most powerful SIMATIC S7-400 CPU. The integral PROFIBUS DP interfaces permit direct connection to the PROFIBUS DP fieldbus as master or slave.

Two further DP master systems can be connected via the IF 964-DP interface submodules.

Note:
Only the interface module 6ES7 964-2AA04-0AB0 can be used.

Обзор



The most powerful SIMATIC S7-400 CPU

  • Applicable for plants with maximum requirements in the high-end performance range
  • With 2 plug-in slots for IF modules

Note:

SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.

Technical documentation on SIPLUS can be found here:
http://www.siemens.de/siplus-extreme

Дизайн



The CPU 417-4 has:

  • Powerful processor:
    The CPU achieves instruction execution times as low as 0.018 µs per binary instruction.
  • 30 MB RAM (of which 15 MB each for program and data);
    fast RAM for parts of the user program relevant to execution.
  • Flexible expansion:
    Up to 262144 digital and 16384 analog inputs/outputs.
  • Multi-point interface MPI:
    With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPU can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
    Note:
    If the PROFIBUS DP interface and MPI interface are operated simultaneously, it is only possible to connect the following bus connector to the MPI interface:
    • With socket: 6ES7 972-0BB42-0XA0
    • Without socket: 6ES7 972-0BA42-0XA0
  • Mode selector switch:
    Designed as toggle switch.
  • Diagnostics buffer:
    The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes (extendable).
  • Real-time clock:
    The date and time are appended to diagnostic messages of the CPU.
  • Memory card:
    For expansion of the integrated load memory. The information in the load memory comprises S7-400 parameterization data in addition to the program and therefore requires twice as much memory space. The result is that:
    • The integral load memory is not sufficient for large programs, therefore a memory card is frequently required.
      RAM and FEPROM cards (FEPROM for retentive storage) are available
  • PROFIBUS DP interface:
    The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user''s point of view, the distributed I/O is treated as central I/O (same configuring, addressing, and programming).
    Mixed configuration: SIMATIC S5 with SIMATIC S7 as PROFIBUS master to EN 50170.
    Note:
    If the PROFIBUS DP and MPI interface are operated simultaneously, it is only possible to connect the following bus connectors to the MPI interface:
    • With socket: 6ES7 972-0BB42-0XA0
    • Without socket: 6ES7 972-0BA42-0XA0
  • Two additional slots:
    Two additional PROFIBUS DP master systems can be connected via IF 964-DP interface modules.

Функции


  • Block protection:
    a password concept also protects the user program from unauthorized access
  • Integrated HMI services:
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
  • Integrated communication functions:
    • PG/OP communication
    • Global data communication
    • S7 standard communication
    • S7 communication

Configurable Attributes

The STEP 7 tool "Hardware configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

  • Multipoint interface MPI:
    • Definition of node addresses
    • Startup/cycle behavior
    • Stipulation of the maximum cycle time and communication load
  • Address allocation:
    Addressing of I/O modules
  • Retentive area:
    Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
  • Size of the process image, local data
  • Length of the diagnostics buffer
  • Protection level:
    Definition of access authorizations to program and data
  • System diagnostics:
    Definition of the handling and scope of diagnostics messages
  • Timed interrupts:
    Setting of periods
  • Configuring

Reporting functions

  • Status and fault indicators:
    LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
  • Test functions:
    The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
  • Information functions:
    The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

Технические данные



Order number

6AG1417-4XT05-4AB0

SIPLUS S7-400 CPU417-4

General information

 

Product type designation

CPU 417-4

Engineering with

 

  • Programming package

STEP7 V 5.3 SP2 or higher with HW update

Supply voltage

 

Rated value (DC)

  • 24 V DC

No; Power supply via system power supply

Power loss

 

Power loss, typ.

7.5 W

Memory

 

Work memory

 

  • integrated

30 Mbyte

  • integrated (for program)

15 Mbyte

  • integrated (for data)

15 Mbyte

Load memory

 

  • expandable FEPROM, max.

64 Mbyte

  • integrated RAM, max.

1 Mbyte

  • expandable RAM, max.

64 Mbyte

CPU processing times

 

for bit operations, typ.

18 ns

for word operations, typ.

18 ns

for fixed point arithmetic, typ.

18 ns

for floating point arithmetic, typ.

54 ns

Counters, timers and their retentivity

 

S7 counter

 

  • Number

2 048

IEC counter

 

  • present

Yes

S7 times

 

  • Number

2 048

IEC timer

 

  • present

Yes

Data areas and their retentivity

 

Flag

 

  • Number, max.

16 kbyte; Size of bit memory address area

Address area

 

I/O address area

 

  • Inputs

16 kbyte

  • Outputs

16 kbyte

Process image

 

  • Inputs, adjustable

16 kbyte

  • Outputs, adjustable

16 kbyte

Hardware configuration

 

Slots

 

  • required slots

2

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

Operating hours counter

 

  • Number

16

Interfaces

 

Interfaces/bus type

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 2 x PROFIBUS DP (optionally pluggable)

Number of RS 485 interfaces

0

Number of other interfaces

0

1. Interface

 

Interface type

Integrated

Physics

RS 485 / PROFIBUS + MPI

Functionality

 

  • MPI

Yes

  • DP master

Yes

  • DP slave

Yes

DP master

 

  • Number of DP slaves, max.

32

2. Interface

 

Interface type

Integrated

Physics

RS 485 / PROFIBUS

Functionality

 

  • DP master

Yes

  • DP slave

Yes

DP master

 

  • Number of DP slaves, max.

125

3. Interface

 

Interface type

Pluggable interface module (IF), technical data as for 2nd interface

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Physics

RS 485 / PROFIBUS

Functionality

 

  • MPI

No

  • DP master

Yes

  • DP slave

Yes

DP master

 

  • Number of DP slaves, max.

125

4. Interface

 

Interface type

Pluggable interface module (IF), technical data as for 2nd interface

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes; For PROFIBUS only

Communication functions

 

PG/OP communication

Yes

Data record routing

Yes

Global data communication

 

  • supported

Yes

S7 basic communication

 

  • supported

Yes

S7 communication

 

  • supported

Yes

S5 compatible communication

 

  • supported

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Standard communication (FMS)

 

  • supported

Yes; Via CP and loadable FB

Open IE communication

 

  • ISO-on-TCP (RFC1006)

Via CP 443-1 and loadable FB

Web server

 

  • supported

No

Number of connections

 

  • overall

64

Ambient conditions

 

Ambient temperature during operation

 

  • min.

0 °C; = Tmin

  • max.

60 °C; = Tmax

Extended ambient conditions

 

  • relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Запрос коммерческого предложения

×


    * Поля, обязательные для заполнения.

    Сообщение отправлено

    ×

    В ближайшее время сообщение будет обработано.

    Письмо с номером обращения отправлено на Ваш почтовый ящик.

    Спасибо за то, что выбрали Первый ZIP!

    Что-то пошло не так...

    ×

    К сожалению, наша система расценила Ваше сообщение как спам.

    Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

    Приносим извинения за возможные неудобства.