SINAMICS G180 cabinet systems Siemens

Обзор



SINAMICS G180 cabinet systems comprise SINAMICS G180 compact units which are combined with Rittal TS8 cabinets and customer-specific control accessories to create individual cabinet systems.

Global use

SINAMICS G180 converter cabinet systems are manufactured in compliance with relevant international standards and regulations, and are therefore suitable for global use (see technical data).

SINAMICS G180 – cabinet system with four compact units

Дизайн


  • Modular principle permits the design of cost-optimized, customized systems
  • A complete installation can be quickly and easily assembled through the integration of various industry-specific control packages
  • Use of CAE/CAM systems increases flexibility and shortens delivery times
  • Capable of integration in any control concept thanks to customized design
  • Capable of adaptation to numerous bus systems
  • Overall concept is devised to minimize space requirements
  • Rittal TS8 cabinet system ensures acceptance anywhere in the world
  • Optimum use of space thanks to different cabinet sizes
  • Easy to adapt to an extensive range of climatic conditions
  • Quick access to all components from front of cabinet eases maintenance
  • Additional fans are not generally required
  • Cable entry from below incl. cable clamping bar, shielding bus and grounding bar

Number of compact units in cabinet system (depending on width)

Compact units

Cabinet system width

 

600 mm

800 mm

1000 mm

1200 mm

165 mm wide

2.2 … 11 kW (400 V)

2.2 … 15 kW (500 V)

3

4

5

6

225 mm wide

15 … 30 kW (400 V)

22 … 37 kW (500 V)

7.5 … 22 kW (690 V)

2

3

4

4

350 mm wide

37 … 110 kW (400 V)

45 … 132 kW (500 V)

30 … 132 kW (690 V)

1

2

2

3

500 mm wide

132 … 160 kW (400 V)

160 … 200 kW (500 V)

160 … 200 kW (690 V)

1

1

1

2



This overview applies to cabinet systems without an additional control system (except for option S31). We would be happy to assist with optimization of the cabinet system width.

Чертеж



Standard cabinet size for cabinet systems (option H81)

Dimensional drawing applies to standard cabinet systems (option H81) with converter without options. The cabinet dimensions might change if options are selected.

Опции



The following tables provide an overview of the options and their availability for SINAMICS G180 compact units in control cabinets (cabinet systems) with a supply voltage of 400 V, 500 V or 690 V. (For details, see catalog chapter 4 "Option descriptions".)

 

 

SINAMICS G180 cabinet systems (compact units installed in a control cabinet)

 

 

400 V TN/TT system

500 V IT system

 

 

Version – see selection and ordering data

Option text

Additional ordering data -Z with order code and, if necessary, with plain text specification

A

B

C

D

E

F

G

H

I

J

K

L

Converter cabinet width

406 mm

H80

606 mm

H81

806 mm

H82

1006 mm

H83

1206 mm

H84

1406 mm

H85

1606 mm

H86

Additional cabinet

400 mm

H90

600 mm

H91

800 mm

H92

1000 mm

H93

1200 mm

H94

Line voltages

Line voltage 380 V, 50 Hz

V70

Line voltage 400 V, 50 Hz

V71

Line voltage 415 V, 50 Hz

V72

Line voltage 500 V, 50 Hz

V73

Line voltage 660 V, 50 Hz

V74

Line voltage 690 V, 50 Hz

V75

Line voltage 440 V, 60 Hz

V76

Line voltage 460 V, 60 Hz

V77

Line voltage 480 V, 60 Hz

V78

Line voltage 600 V, 60 Hz

V79

Line voltage 660 V, 60 Hz

V80

Special line voltage; please specify voltage

Y70 • and identification code

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

1)

External auxiliary power supply

Connection for 230 V 1 AC 50 Hz auxiliary voltage provided by customer

C36

Connection for 400 V 3 AC 50 Hz auxiliary voltage provided by customer

C38

Connection for 500 V 3 AC 50 Hz auxiliary voltage provided by customer

C43

Connection for 690 V 3 AC 50 Hz auxiliary voltage provided by customer

C48

Connection for other 3 AC voltage provided by customer; please specify voltage

Y36 • and identification code

External control voltage supply

Connection for 230 V 1 AC 50 Hz control voltage provided by customer, without UPS backup

C56

Connection for 230 V 1 AC 50 Hz control voltage provided by customer, with UPS backup

C57

Connection for different 1 AC control voltage (47 to 63 Hz) provided by customer; please specify voltage

Y55 • and identification code

RFI suppression filter

RFI suppression filter, category C2 or C3 (class A)

L00

RFI suppression filter, category C1 (class B)

L02

Line Harmonics Filter

Line Harmonics Filter for 50 Hz line frequency up to 500 V

L03

H813)

H813)

H823)

H823)

H813)
+
H913)

H813)
+
H913)

H813)

H813)

H823)

H823)

H813)
+
H913)

H813)
+
H913)

Line Harmonics Filter for 60 Hz line frequency up to 480 V

L04

H813)

H813)

H823)

H823)

H813)
+
H913)

H813)
+
H913)

H813)

H813)

H823)

H823)

H813)
+
H913)

H813)
+
H913)

Output filter

Strengthened dv/dt output filter for max. 250/300 m (type-dependent). Design for longer motor cables available on request

L10

Sine-wave filter integrated in control cabinet, suitable for motor frequencies of ≤ 75 Hz, voltage drop of approximately 5 % of line voltage

L17

H813)
+
H913)

H813)
+
H913)

Standard accessories packages

Peripheral board 4 (G05) instead of peripheral board 2 (G03) (only in conjunction with package S01, S02, S03, S04, S08, S09, S11, S12)

G08

Accessories package S01 with main switch, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch

S01

Accessories package S02 with circuit breaker, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch

S02

Accessories package with main switch, line contactor, board G03, local/remote switch

S03

Accessories package with circuit breaker, line contactor, board G03, local/remote switch

S04

Accessories package with main switch, line contactor, Calomat, RCU box connection

S06

Bypass for smooth line synchronization (soft start function) incl. line-side main switch and contactors at the converter output and in bypass

S08

H823)

H833)

H823)

H833)

Bypass for smooth line synchronization (soft start function) incl. line-side circuit breaker and contactors at the converter output and in bypass

S09

H823)

H833)

H823)

H833)

Accessories package S11 with line-side main switch, board G03, local/remote switch

S11

Accessories package S12 with line-side circuit breaker, board G03, local/remote switch

S12

Bypass with line-side main switch, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch

S21

H823)

H833)

H823)

H833)

Bypass with line-side circuit breaker, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch

S22

H823)

H833)

H823)

H833)

Bypass with line-side main switch, contactors at converter output and in bypass, EMERGENCY OFF safety relay, switchover between manual and automatic, local/remote switch

S23

H823)

H833)

H823)

H833)

Bypass with line-side circuit breaker, contactors at converter output and in bypass, EMERGENCY OFF safety relay, switchover between manual and automatic, local/remote switch

S24

H823)

H833)

H823)

H833)

NAMUR a

Запрос коммерческого предложения

×

    * Поля, обязательные для заполнения.

    Сообщение отправлено

    ×

    В ближайшее время сообщение будет обработано.

    Письмо с номером обращения отправлено на Ваш почтовый ящик.

    Спасибо за то, что выбрали Первый ZIP!

    Что-то пошло не так...

    ×

    К сожалению, наша система расценила Ваше сообщение как спам.

    Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

    Приносим извинения за возможные неудобства.