SINAMICS G180 cabinet units - air-cooled and liquid-cooled Siemens

Обзор



Example of SINAMICS G180 air-cooled converter cabinet unit

With its SINAMICS G180 cabinet units, Siemens is offering a drive system on which all line-side and motor-side components are integrated extremely compactly into a specially designed cabinet enclosure. This approach minimizes the effort and expense required to configure and install them.
SINAMICS G180 cabinet units are available in air-cooled and liquid-cooled versions.

SINAMICS G180 converter cabinet units are available for the following voltages and power ratings:

Rated line voltage

Power

400 V 3 AC

200 ... 630 kW1)

500 V 3 AC

250 ... 800 kW1)

690 V 3 AC

250 ... 6600 kW



1) Higher outputs available on request.

Global use

SINAMICS G180 converter cabinet units are manufactured in compliance with relevant international standards and regulations, and are therefore suitable for global use (see technical data).

Air-cooled converter cabinet units

Air-cooled converter cabinet units are equipped with an ingeniously designed, highly efficient air guidance system which is quiet in operation.

Liquid-cooled converter cabinet units

These specially designed liquid-cooled versions of the SINAMICS G180 converter cabinet unit are extremely quiet in operation. Closed control cabinets in degree of protection IP54 or higher make these liquid-cooled converters suitable for applications in harsh environmental conditions.

The advantages of the liquid-cooled version as compared to the air-cooled version are as follows:

  • Very low thermal loading of switch rooms
  • Can be used almost anywhere, even in atmospheres harmful to machines, thanks to the IP55 degree of protection (IP54 with display in cabinet door)
  • Reliable even at higher ambient temperatures up to 55° C thanks to optimal cooling effect
  • Reduced noise emission through elimination of the cooling ventilation
  • Improved efficiency
  • The water-conveying parts of the cooling system are made of stainless steel (V2A), making it resistant to almost any water quality

Опции



The following tables provide an overview of the options and their availability for SINAMICS G180 cabinet units with a supply voltage of 400 V, 500 V or 690 V. (For details, see catalog chapter 4 "Option descriptions".)

 

 

Air-cooled and liquid-cooled versions of SINAMICS G180 cabinet units

 

 

400 V

500 V

690 V

Pulse number

 

6

12

6

12

6

12
18
24

  

Version – see selection and ordering data

Option text

Additional ordering data -Z with order code and, if necessary, with plain text specification

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

Line voltages

Line voltage 380 V, 50 Hz

V70

Line voltage 400 V, 50 Hz

V71

Line voltage 415 V, 50 Hz

V72

Line voltage 500 V, 50 Hz

V73

Line voltage 660 V, 50 Hz

V74

Line voltage 690 V, 50 Hz

V75

Line voltage 440 V, 60 Hz

V76

Line voltage 460 V, 60 Hz

V77

Line voltage 480 V, 60 Hz

V78

Line voltage 600 V, 60 Hz

V79

Line voltage 660 V, 60 Hz

V80

Special line voltage; please specify voltage

Y70 • and identification code

1)

1)

1)

1)

1)

2)

2)

2)

3)

3)

3)

3)

3)

3)

3)

Additional cabinet

400 mm

H90

600 mm

H91

800 mm

H92

1000 mm

H93

1200 mm

H94

External auxiliary power supply

Connection for 230 V 1 AC 50 Hz auxiliary voltage provided by customer

C36

Connection for 400 V 3 AC 50 Hz auxiliary voltage provided by customer

C38

Connection for 500 V 3 AC 50 Hz auxiliary voltage provided by customer

C43

Connection for 690 V 3 AC 50 Hz auxiliary voltage provided by customer

C48

Connection for other 3 AC voltage provided by customer; please specify voltage

Y36 • and identification code

External control voltage supply

Connection for 230 V 1 AC 50 Hz control voltage provided by customer, without UPS backup

C56

Connection for 230 V 1 AC 50 Hz control voltage provided by customer, with UPS backup

C57

Connection for different 1 AC control voltage (47 to 63 Hz) provided by customer; please specify voltage

Y55 • and identification code

Other option

Board for mains supply backup

E85

RFI suppression filter

RFI suppression filter, category C2 or C3 (class A)

L00

Line Harmonics Filter

Line Harmonics Filter for 50 Hz line frequency

L03

H926)

H926)

H936)

5)

H936)

5)

H926)

H936)

5)

H926)

H936)

5)

Line Harmonics Filter for 60 Hz line frequency

L04

H926)

H926)

H936)

5)

H936)

5)

H926)

H936)

5)

H926)

H936)

5)

Output filter

Strengthened dv/dt output filter for max. 250/300 m (type-dependent). Design for longer motor cables available on request

L10

4)

4)

4)

4)

4)

4)

4)

Sine-wave filter integrated in control cabinet or additional cabinet, suitable for motor frequencies of ≤ 75 Hz, voltage drop of approximately 10 % of line voltage

L14

H916)

H926)

H926)

H926)

5)

H916)

H926)

5)

Sine-wave filter integrated in control cabinet or additional cabinet, suitable for motor frequencies of ≤ 60 Hz, voltage drop of approximately 10 % of line voltage

L15

5)

5)

5)

5)

5)

5)

5)

Standard accessories packages

Peripheral board 4 (G05) instead of peripheral board 2 (G03) (only in conjunction with package S01, S02, S03, S04, S08, S09, S11, S12)

G08

Accessories package S01 with main switch, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch

S01

Accessories package S02 with circuit breaker, line contactor, EMERGENCY OFF pushbutton and safety relay, board G03, local/remote switch

S02

Accessories package with main switch, line contactor, board G03, local/remote switch

S03

Accessories package with circuit breaker, line contactor, board G03, local/remote switch

S04

Accessories package with main switch, line contactor, Calomat, RCU box connection

S06

Bypass for smooth line synchronization (soft start function) incl. line-side main switch and contactors at the converter output and in bypass

S08

H926)

H926)

H926)

H926)

5)

H926)

H926)

5)

H926)

H926)

H926)

5)

5)

5)

5)

Bypass for smooth line synchronization (soft start function) incl. line-side circuit breaker and contactors at the converter output and in bypass

S09

H926)

H926)

H926)

H926)

5)

H926)

H926)

5)

H926)

H926)

H926)

5)

5)

5)

5)

Accessories package S11 with line-side main switch, board G03, local/remote switch

S11

Accessories package S12 with line-side circuit breaker, board G03, local/remote switch

S12

Bypass with line-side main switch, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch

S21

H916)

H916)

H916)

H916)

5)

H916)

H916)

5)

H916)

H916)

H916)

5)

5)

5)

5)

Bypass with line-side circuit breaker, contactors at converter output and in bypass, switchover between manual and automatic, local/remote switch

S22

H916)

H916)

H916)

H916)

5)

H916)

H916)

5)

Запрос коммерческого предложения

×

    * Поля, обязательные для заполнения.

    Сообщение отправлено

    ×

    В ближайшее время сообщение будет обработано.

    Письмо с номером обращения отправлено на Ваш почтовый ящик.

    Спасибо за то, что выбрали Первый ZIP!

    Что-то пошло не так...

    ×

    К сожалению, наша система расценила Ваше сообщение как спам.

    Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

    Приносим извинения за возможные неудобства.