Minimum Order Quantity 1 piece Customs Tariff Number 85364900 Popular Downloads
Data Sheet, Technical Information 1SNC001003C0202 Instructions and Manuals 1SBC101007M5501 Dimension Diagram FPTE307864 Dimensions
Product Net Width 54 mm Product Net Depth 125.3 mm Product Net Height 90 mm Product Net Weight 0.850 kg Technical
Number of Main Contacts NO 3 Number of Main Contacts NC 0 Number of Auxiliary Contacts NO 1 Number of Auxiliary Contacts NC 0 Rated Operational Voltage Main Circuit 690 V Auxiliary Circuit 690 V Rated Frequency (f) Supply Circuit 50 Hz Supply Circuit 60 Hz Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A acc. to IEC 60947-5-1, q = 40 °C 16 A Rated Operational Current AC-1 (Ie) (690 V) 40 °C 60 A (690 V) 55 °C 60 A (690 V) 70 °C 42 A Rated Operational Current AC-3 (Ie) (220 / 230 / 240 V) 55 °C 40 A (380 / 400 V) 55 °C 37 A (415 V) 55 °C 37 A (440 V) 55 °C 37 A (500 V) 55 °C 33 A (690 V) 55 °C 21 A Rated Operational Power AC-3 (Pe) (220 / 230 / 240 V) 11 kW (380 / 400 V) 18.5 kW (415 V) 18.5 kW (440 V) 22 kW (500 V) 22 kW (690 V) 18.5 kW Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1 10 x Ie AC-3 Rated Operational Current AC-15 (Ie) (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Short-Circuit Protective Devices Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 63 A Rated Short-time Withstand Current (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A for 0.1 s 140 A for 1 s 100 A Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 470 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 175 A Maximum Electrical Switching Frequency AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour Rated Operational Current DC-13 (Ie) (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Impulse Withstand Voltage (Uimp) 8 kV Mechanical Durability 10 million Maximum Mechanical Switching Frequency 3600 cycles per hour Rated Control Circuit Voltage (Uc) DC Operation 77 … 143 V Coil Consumption Holding DC (Umin / Umax) 2.7 / 9 W Pull-in DC (Umin / Umax) 2.7 / 9 W Operate Time Between Coil Energization and NO Contact Closing 55 ... 110 ms Between Coil De-energization and NO Contact Opening 12 ... 18 ms Connecting Capacity Main Circuit Rigid Cable 2.5 ... 16 mm² Flexible with Cable End 2.5 ... 10 mm² Connecting Capacity Auxiliary Circuit Rigid Cable 1 ... 4 mm² Flexible with Cable End 0.75 ... 2.5 mm² Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 Connecting terminals (delivered in open position) Main poles M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector Terminal Type Screw Terminals Environmental
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay -40 ... +55 °C Climatic Withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II Maximum Operating Altitude Permissible 3000 m Resistance to Shock acc. to IEC 60068-2-27 Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g RoHS Status Following EU Directive 2002/95/EC August 18, 2005 and amendment Container Information
Package Level 1 Units 1 piece Package Level 1 Width 100 mm Package Level 1 Length 134 mm Package Level 1 Height 62 mm Package Level 1 Gross Weight 0.85 kg Package Level 1 EAN 3471522325624 Package Level 2 Units 20 piece Package Level 3 Units 384 piece Classifications
Object Classification Code Q ETIM 4 EC000066 - Magnet contactor, AC-switching ETIM 5 EC000066 - Magnet contactor, AC-switching ETIM 6 EC000066 - Power contactor, AC switching UNSPSC 39121529
О компании ABB
ABB – высокотехнологичная компания, лидирующая в разработке систем автоматизации промышленных производств. Её история началась ещё 130 лет назад, и сейчас филиалы ABB работают в 100 странах, а количество служащих превышает 135,000 человек.
Уже более 40 лет специалисты ABB занимаются разработкой инновационных технологий цифрового соединения и управления промышленным оборудованием и системами. За это время на предприятиях заказчиков были установлены и введены в эксплуатацию 70,000 систем управления, объединяющие более 70 миллионов устройств.
Каждый день компания выпускает новые решения безопасности, эффективности и продуктивности для коммунальной и промышленной сферы, транспорта и инфраструктуры по всему миру.
Вся продукция, системы и комплексные решения ABB разрабатываются с заботой об окружающей ... Читать далее...






Ответ от производителя может занять до 5 дней и более.