ABB — . BC6-30-10-P-03 Mini Contactor 60VDC - BC6-30-10-P-03 GJL1213009R0103

Extended Product Type:BC6-30-10-P-03
Product ID:GJL1213009R0103
EAN:4013614053351
Catalog Description:BC6-30-10-P-03 Mini Contactor 60VDC
Long Description:The BC6-30-10-P mini contactor is a compact 3 pole contactor with 1 auxiliary contact and soldering pins. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil and a switch position indication.
Артикул «Первый ZIP»:1024688
Артикул производителя:GJL1213009R0103
Доп. код производителя:SSTGJL1213009R0103
Наличие

Наличие

Только под заказ.
Ориентировочный срок поставки: 21 день.
Цена

Цена

Требуется запрос производителю.

Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.

Ответим на Ваш запрос сегодня в течение дня.

Доставка

Доставка

По всей России.
  • транспортной компанией на Ваш выбор
  • самовывоз из офиса в Санкт-Петербурге
  • бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Узнайте, как мы работаем
Коммерческое предложение
Удобно для запроса одной позиции
Добавить в корзину

Товар в корзине.

Перейти в корзину
Удобно для запроса нескольких разных позиций
  • Accessories

    Ordering

    Minimum Order Quantity1 piece
    Customs Tariff Number85365080

    Popular Downloads

    Data Sheet, Technical Information1SBC100173C0201
    Instructions and Manuals2CDC102047M6801
    Dimension DiagramGJL1200438F0001

    Dimensions

    Product Net Width47.5 mm
    Product Net Height45.5 mm
    Product Net Depth51.5 mm
    Product Net Weight0.17 kg

    Technical

    Number of Poles4
    Mini Contactor TypeMini Contactor
    Rated Operational VoltageAuxiliary Circuit 12 ... 240 V DC Auxiliary Circuit 12 ... 500 V AC/DC Main Circuit 12 ... 690 V AC/DC Main Circuit 690 V AC
    Rated Frequency (f)Control Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
    Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV Main Circuit 6 kV
    Rated Insulation Voltage (Ui)690 V acc. to UL/CSA 600 V
    Number of Main Contacts NC0
    Number of Main Contacts NO3
    Rated Operational Current AC-1 (Ie)(220 / 240 V) 40 °C 12 A (220 / 240 V) 55 °C 12 A (380 / 440 V) 40 °C 12 A (380 / 440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
    Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 2.2 kW (400 V) 4 kW (400 V) Three Phase 4 kW (440 V) 4 kW (500 V) 4 kW (690 V) 3 kW
    Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
    Number of Auxiliary Contacts NC0
    Number of Auxiliary Contacts NO1
    Rated Operational Current AC-15 (Ie)(120 V) 4 A (220 / 240 V) 4 A (24 V) 4 A (380 / 400 V) 3 A (500 V) 2 A
    Rated Operational Current DC-13 (Ie)(110 V) 0.7 A (220 / 240 V) 0.4 A (24 V) 2.5 A
    Conventional Free-air Thermal Current (Ith)Main Circuit 12 A
    Rated Control Circuit Voltage (Uc)60 V DC
    Coil Operating Limits(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
    Degree of ProtectionAuxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20
    Mechanical Durability10000000 cycle
    Minimum Switching Capacity17 V 5 mA
    Maximum Electrical Switching FrequencyAC-1 300 cycles per hour AC-15 600 cycles per hour AC-3 600 cycles per hour DC-1 600 cycles per hour DC-13 600 cycles per hour DC-3 600 cycles per hour
    Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    Power Lossat Rated Operating Conditions per Pole 2 W
    StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1

    Environmental

    Ambient Air TemperatureOperation -25 ... +55 °C Storage -40 ... +80 °C
    Maximum Operating Altitude Permissible2000 m
    Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
    Resistance to Vibrations acc. to IEC 60068-2-65g / 5 ... 150 Hz
    RoHS StatusFollowing EU Directive 2002/95/EC August 18, 2005 and amendment

    Technical UL/CSA

    Maximum Operating Voltage UL/CSAMain Circuit 600 V AC Auxiliary Circuit 600 V AC/DC
    Full Load Amps Motor Use(240 V AC) Single Phase 4.9 A (440 ... 480 V AC) Three Phase 4.8 A
    Horsepower Rating UL/CSA(208 V AC) Three Phase 1 Hp (220 ... 240 V AC) Single Phase 0.5 Hp (220 ... 240 V AC) Three Phase 2 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 1 Hp
    General Use Rating UL/CSA(300 V AC) 8 A

    Container Information

    Package Level 1 Units10 piece
    Package Level 1 Width108 mm
    Package Level 1 Height69 mm
    Package Level 1 Length247 mm
    Package Level 1 Gross Weight1.775 kg
    Package Level 1 EAN4013614415104

    Classifications

    Object Classification CodeQ
    ETIM 4EC000066 - Magnet contactor, AC-switching
    ETIM 5EC000066 - Magnet contactor, AC-switching
    ETIM 6EC000066 - Power contactor, AC switching
    eClass7.0 27371003
Товар на сайте производителя: ABB GJL1213009R0103

О компании ABB

ABB – высокотехнологичная компания, лидирующая в разработке систем автоматизации промышленных производств. Её история началась ещё 130 лет назад, и сейчас филиалы ABB работают в 100 странах, а количество служащих превышает 135,000 человек.

Уже более 40 лет специалисты ABB занимаются разработкой инновационных технологий цифрового соединения и управления промышленным оборудованием и системами. За это время на предприятиях заказчиков были установлены и введены в эксплуатацию 70,000 систем управления, объединяющие более 70 миллионов устройств.

Каждый день компания выпускает новые решения безопасности, эффективности и продуктивности для коммунальной и промышленной сферы, транспорта и инфраструктуры по всему миру.

Вся продукция, системы и комплексные решения ABB разрабатываются с заботой об окружающей ... Читать далее...