Fault annunciators DOLD
Показано товаров: 10 из 26
Артикул: 1325106
• New fault annunciation with single frequency flashlight according to DIN 19 235
• Expandable from 16 up to 160 inputs
• in 2 groups of 8 inputs selectable:
- open circuit operation
- closed circuit operation
• Input voltage up to max. AC/DC 240 V
• Delayed inputs
• Exchangable front for individual scale
• Removable terminals
• Flush mounting
• Frame 72 x 144 mm
EP 5966:
• 16 inputs in control unit
• Output relay for common signal and audible alarm
• Built in and external connected pushbuttons for lamp test (LT),
acknowledgement of horn (QH) and of alarm (QS)
• Extension module with 16 inputs
• Expandable from 16 up to 160 inputs
• in 2 groups of 8 inputs selectable:
- open circuit operation
- closed circuit operation
• Input voltage up to max. AC/DC 240 V
• Delayed inputs
• Exchangable front for individual scale
• Removable terminals
• Flush mounting
• Frame 72 x 144 mm
EP 5966:
• 16 inputs in control unit
• Output relay for common signal and audible alarm
• Built in and external connected pushbuttons for lamp test (LT),
acknowledgement of horn (QH) and of alarm (QS)
• Extension module with 16 inputs
Артикул: 1325105
• Text display for DOLD fault annunciator system INFOMASTER B with base module RP 5994
• To display up to 88 fault messages with 80, 40 or 20 characters each
• Operating mode adjustable on base module RP 5994 for new, first or common alarm
• Reset buttons for individual alarm signal, audible alarm and common alarm on front side
• RS 485 bus connection, as option with galvanic separation
• Alarms and resets can be transmitted by SMS via GSM module RP 5810
• SMS communication is possible with up to 16 receivers
• Configuration of the text display via USB-Stick (acceccories OA 5996 Article-No. 0065659), therefore no laptop on site is necessary
• Real time clock
• Operating language for menus and failure text in English, German and French
• Up to 3 variable parameters in one message text
• 2 password levels for device configuration
• To display up to 88 fault messages with 80, 40 or 20 characters each
• Operating mode adjustable on base module RP 5994 for new, first or common alarm
• Reset buttons for individual alarm signal, audible alarm and common alarm on front side
• RS 485 bus connection, as option with galvanic separation
• Alarms and resets can be transmitted by SMS via GSM module RP 5810
• SMS communication is possible with up to 16 receivers
• Configuration of the text display via USB-Stick (acceccories OA 5996 Article-No. 0065659), therefore no laptop on site is necessary
• Real time clock
• Operating language for menus and failure text in English, German and French
• Up to 3 variable parameters in one message text
• 2 password levels for device configuration
Артикул: 1325116
• Permanent sound, pitch fixed
• optionally with switchable interval- / permanent sound
and 2 pitches settable
• Width: 17.5 mm and depth: 64 mm
• optionally with switchable interval- / permanent sound
and 2 pitches settable
• Width: 17.5 mm and depth: 64 mm
Артикул: 1325104
Display unit EH 5994, EH 5995
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP 64
• Enclosure for flush mounting 96 x 96 mm
• Display unit EH 5994:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm, common alarm and alarm signal
• Display unit EH 5995:
- 8 fault signal LEDs on the unit
- Without reset buttons
• Exchangable front label for individual legending
• As option galvanic separated RS458 bus
• Protection degree for front side IP 64
• Enclosure for flush mounting 96 x 96 mm
• Display unit EH 5994:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm, common alarm and alarm signal
• Display unit EH 5995:
- 8 fault signal LEDs on the unit
- Without reset buttons
Артикул: 1325115
• Permanent sound, pitch fixed
• optionally with switchable interval- / permanent sound
• Devices available in 2 enclosure versions:
- I- and-version, e.g. IK _ _ _ _ with depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
- S-version, e.g. SK _ _ _ _ with depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width: 17,5 mm
• optionally with switchable interval- / permanent sound
• Devices available in 2 enclosure versions:
- I- and-version, e.g. IK _ _ _ _ with depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880
- S-version, e.g. SK _ _ _ _ with depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width: 17,5 mm
Артикул: 1325099
New- / First- /Common Signal Annunciator RP 5994, RP 5995
• Fast localisation of failures and their causes
• Reduction of standstill times in production
• Adjustable operating modes:
New- / First signal annunciator according to DIN 19 235,
common alarm annunciator manual reset / auto reset settable
• Expandable from 8 to 88 fault signals
• Open or closed circuit operation settable
• Adjustable on delay for input signals 0 to 10 sec
• Reset buttons for audible alarm and common alarm on front side
• Connection for external reset of audible alarm, common alarm
and single alarm according to setting
• Galvanic separation to bus RS485 (optional)
• Accessories: buzzer RK 8832, display unit EH 5994, EH 5995
text display unit EH 5996, GMS-module RP 5810
• Width: 70 mm
Base module RP 5994:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
Extension module RP 5995:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm (on request)
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
• Fast localisation of failures and their causes
• Reduction of standstill times in production
• Adjustable operating modes:
New- / First signal annunciator according to DIN 19 235,
common alarm annunciator manual reset / auto reset settable
• Expandable from 8 to 88 fault signals
• Open or closed circuit operation settable
• Adjustable on delay for input signals 0 to 10 sec
• Reset buttons for audible alarm and common alarm on front side
• Connection for external reset of audible alarm, common alarm
and single alarm according to setting
• Galvanic separation to bus RS485 (optional)
• Accessories: buzzer RK 8832, display unit EH 5994, EH 5995
text display unit EH 5996, GMS-module RP 5810
• Width: 70 mm
Base module RP 5994:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
Extension module RP 5995:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm (on request)
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
Артикул: 1325097
Common Alarm Annunciator RP 5990, RP 5991
• Fast localisation of failures and their causes
• Reduction of standstill times in production
• Common alarm annunciator with manual or auto reset of faults
• Expandable from 8 to 88 fault signals
• Open or closed circuit operation settable with rotational switch on base unit and with link X1/X2 on extension units
• Adjustable on delay for input signals 0 to 10 sec
• Reset buttons for audible alarm and common alarm on front side
• Connection for external reset of audible alarm
• Galvanic separation to bus RS485 (optional)
• Accessories: buzzer RK 8832, display unit EH 5990, EH 5991
• Width: 70 mm
• Base Module RP 5990:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm and common alarm
- Connection for external reset of audible alarm
• Extension Module RP 5991:
- 8 fault signal inputs with indicator LED on the unit
- As option one relay output each for audible alarm and common alarm
- As option reset buttons for audible alarm and common alarm
• Fast localisation of failures and their causes
• Reduction of standstill times in production
• Common alarm annunciator with manual or auto reset of faults
• Expandable from 8 to 88 fault signals
• Open or closed circuit operation settable with rotational switch on base unit and with link X1/X2 on extension units
• Adjustable on delay for input signals 0 to 10 sec
• Reset buttons for audible alarm and common alarm on front side
• Connection for external reset of audible alarm
• Galvanic separation to bus RS485 (optional)
• Accessories: buzzer RK 8832, display unit EH 5990, EH 5991
• Width: 70 mm
• Base Module RP 5990:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm and common alarm
- Connection for external reset of audible alarm
• Extension Module RP 5991:
- 8 fault signal inputs with indicator LED on the unit
- As option one relay output each for audible alarm and common alarm
- As option reset buttons for audible alarm and common alarm
Артикул: 1325093
• According to DIN 19235
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm
Fault annunciator IL 5990, SL 5990:
• 4 inputs with LED on control unit
• 1 output for common signal and 1 output for audible alarm
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm
Fault annunciator IL 5990, SL 5990:
• 4 inputs with LED on control unit
• 1 output for common signal and 1 output for audible alarm
Артикул: 1325091
• Common alarm annunciator for 6 signals
• Optionally for up to 8 signals
• Closed circuit operation
• Optionally with open circuit operation
• With LED for each fault signal
• Inputs up to AC/DC 300 V
• With relay output for common signal
• Pushbutton for fault signal acknowledgement and function test
• Front surface 96 x 96 mm
• Optionally for up to 8 signals
• Closed circuit operation
• Optionally with open circuit operation
• With LED for each fault signal
• Inputs up to AC/DC 300 V
• With relay output for common signal
• Pushbutton for fault signal acknowledgement and function test
• Front surface 96 x 96 mm
Артикул: 1325095
• According to DIN 19235
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm
Fault annunciator IL 5990, SL 5990:
• 4 inputs with LED on control unit
• 1 output for common signal and 1 output for audible alarm
• Common alarm annunciator
• Expandable from 4 up to 160 inputs
• Open circuit inputs / closed circuit inputs selectable via bridges X1-X2
• Delayed inputs up to 10 s
• Acknowledgement push button QH for external buzzer built in
• Accessories: Buzzer IK 8832, SK 8832
• Devices available in 2 enclosure versions:
I-model: depth 61 mm, with terminals at the bottom for installations systems and industrial distribution systems according to DIN 43 880
S-model: depth 100 mm, with terminals at the top for cabinets with mounting plate and cable duct
• Width 35 mm
Fault annunciator IL 5990, SL 5990:
• 4 inputs with LED on control unit