Softstarters DOLD
Показано товаров: 10 из 20
Артикул: 1325155
• 3-phase softstarter for asynchronous motors up to 800 kW (400 V)
• W3 connection up to 1300 kW (400V)
• Nominal current 23 ... 1600 A
• Integrated bridging contactor up to 220 A
• Programmable in- and outputs for fault indication and operation
• Motor-PTC connection possible
• Communication interfaces as option for Profibus, Devicenet or Modbus
• Start and stop via seperate push buttons or control switch
Adjustable functions:
• Emergency operation
• Slow motion operation forward and reverse
• Control input (3 x fixed, 1 x programmable)
• Relay output (3 x programmable)
• 24 V DC output
• Analogue output
• Different softstart / stop modes
• 690 V units on request
• W3 connection up to 1300 kW (400V)
• Nominal current 23 ... 1600 A
• Integrated bridging contactor up to 220 A
• Programmable in- and outputs for fault indication and operation
• Motor-PTC connection possible
• Communication interfaces as option for Profibus, Devicenet or Modbus
• Start and stop via seperate push buttons or control switch
Adjustable functions:
• Emergency operation
• Slow motion operation forward and reverse
• Control input (3 x fixed, 1 x programmable)
• Relay output (3 x programmable)
• 24 V DC output
• Analogue output
• Different softstart / stop modes
• 690 V units on request
Артикул: 1325139
• Softstart with softstop
• For motors from 1.5 kW to 7.5 kW
• 2-phase control
• Adjustable ramp time, starting torque and starting voltage
• Kickstart-(Boost-)function
• DIN-rail mounting
• Width: 45 mm
• For motors from 1.5 kW to 7.5 kW
• 2-phase control
• Adjustable ramp time, starting torque and starting voltage
• Kickstart-(Boost-)function
• DIN-rail mounting
• Width: 45 mm
Артикул: 1325140
• According to IEC/EN 60 947-4-2
• 3-phase controlled with integrated bypass relays
• Phase sequence monitoring
• Undervoltage monitoring
• Overvoltage monitoring
• Blocked motor monitoring in bypass mode
• Integrated motor protection to class 10 acc. to IEC/EN 60947-4-2
• Starting current limitation
• Thyristor monitoring
• Detection of missing load
• Automatic frequency detection of supply voltage
• Temperature monitoring of power semiconductors
• 3-phase controlled with integrated bypass relays
• Phase sequence monitoring
• Undervoltage monitoring
• Overvoltage monitoring
• Blocked motor monitoring in bypass mode
• Integrated motor protection to class 10 acc. to IEC/EN 60947-4-2
• Starting current limitation
• Thyristor monitoring
• Detection of missing load
• Automatic frequency detection of supply voltage
• Temperature monitoring of power semiconductors
Артикул: 1325141
• Increases life of 1-phase squirrel motors and mechanical drives
• Devices available in 2 enclosure version:
IL 9017: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution systems
according to DIN 43 880
SL 9017: depth 100 mm with terminals at the top for
cabinets with mounting plate and cable duct
• For single phase motors up to 1.5 kW
• Adjustable ramp time and starting torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
• Devices available in 2 enclosure version:
IL 9017: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution systems
according to DIN 43 880
SL 9017: depth 100 mm with terminals at the top for
cabinets with mounting plate and cable duct
• For single phase motors up to 1.5 kW
• Adjustable ramp time and starting torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
Артикул: 1325142
• Increases life of 1-phase squirrel motors and mechanical drives
• Devices available in 2 enclosure version:
IL 9017: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution systems
according to DIN 43 880
SL 9017: depth 100 mm with terminals at the top for
cabinets with mounting plate and cable duct
• For single phase motors up to 1.5 kW
• Adjustable ramp time and starting torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
• Devices available in 2 enclosure version:
IL 9017: depth 61 mm with terminals at the bottom for
installations systems and industrial distribution systems
according to DIN 43 880
SL 9017: depth 100 mm with terminals at the top for
cabinets with mounting plate and cable duct
• For single phase motors up to 1.5 kW
• Adjustable ramp time and starting torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
Артикул: 1325143
• Increases life of 1-phase squirrel motors and mechanical drives
• For single phase motors up to 1.5 kW
• Adjustable ramp time/deceleration time and starting torque/
deceleration torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
• For single phase motors up to 1.5 kW
• Adjustable ramp time/deceleration time and starting torque/
deceleration torque
• Semiconductors will be bridged after start up
• LED indication
• Width 35 mm
Артикул: 1325145
• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 1 phase control
• For motors up to 5,5 kW (BA 9010) and to 11 kW (BN 9011)
• Semiconductors bridged after softstart
• Adjustable ramp time and starting torque
• LED indication
• DIN-rail mounting
• BN 9011: width 100 mm
• Easily fitted to existing installations
• 1 phase control
• For motors up to 5,5 kW (BA 9010) and to 11 kW (BN 9011)
• Semiconductors bridged after softstart
• Adjustable ramp time and starting torque
• LED indication
• DIN-rail mounting
• BN 9011: width 100 mm
Артикул: 1325147
• According to EN 60 947-4-2
• For controlling of 3-phase motors up to 750 W
• With 2-phase softstart and softstop
• Temperature monitoring of the motors with PTC or thermal switch
• 3 potentiometer for adjustment of softstart, softstop
and starting - deceleration time
• 3 LED-indicators
• Reversing with relays, softstart and softstop with thyristors
• 2 x 24 V-inputs for clockwise rotation, anticlockwise rotation
• short circuit proof for 24 V monitoring output
• galvanic separation of control circuit and power circuit
• Width 72 mm
• For controlling of 3-phase motors up to 750 W
• With 2-phase softstart and softstop
• Temperature monitoring of the motors with PTC or thermal switch
• 3 potentiometer for adjustment of softstart, softstop
and starting - deceleration time
• 3 LED-indicators
• Reversing with relays, softstart and softstop with thyristors
• 2 x 24 V-inputs for clockwise rotation, anticlockwise rotation
• short circuit proof for 24 V monitoring output
• galvanic separation of control circuit and power circuit
• Width 72 mm
Артикул: 1325148
• 2-phase softstarter for asynchronous motors up to 110 kW (400 V)
• Integrated current control time
• Integrated motor protector
• Integrated bridging contactor
• Volt free coltrol input for softstart / -stop
• Connection for motor thermistor
• With two monitoring outputs, one is programmable
• DIN rail mounting with devices up to 30 kW
• Communication interfaces for Profibus, DeviceNet,
Modbus and pump controls (optional)
• Start and stop via seperate push buttons or control switch
• Motor voltage range 3 AC 200 ... 440V or 3 AC 200 ... 575V
Adjustable functions:
• Starting time monitoring
• Nominal motor current
• Current ramp
• Current limit
• Softstopp - ramp time
• Motor protection class
• Phase sequence
• Programmable relay output for indicators
• Integrated current control time
• Integrated motor protector
• Integrated bridging contactor
• Volt free coltrol input for softstart / -stop
• Connection for motor thermistor
• With two monitoring outputs, one is programmable
• DIN rail mounting with devices up to 30 kW
• Communication interfaces for Profibus, DeviceNet,
Modbus and pump controls (optional)
• Start and stop via seperate push buttons or control switch
• Motor voltage range 3 AC 200 ... 440V or 3 AC 200 ... 575V
Adjustable functions:
• Starting time monitoring
• Nominal motor current
• Current ramp
• Current limit
• Softstopp - ramp time
• Motor protection class
• Phase sequence
• Programmable relay output for indicators
Артикул: 1325157
• Increases life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 3-phase control softstart and softstop
• For motors up to 55 kW
• Start current limited to 2 to 3 times rated motor current
• Semiconductors bridged after softstart
• Adjustable ramp time, starting torque and deceleration time
• Integrated temperature monitoring of semiconductors
• Thermistor temperature monitoring of the motor
• 7.5 ... 22 kW: enclosure width 304 mm
30 ... 55 kW: enclosure width 335 mm
• Easily fitted to existing installations
• 3-phase control softstart and softstop
• For motors up to 55 kW
• Start current limited to 2 to 3 times rated motor current
• Semiconductors bridged after softstart
• Adjustable ramp time, starting torque and deceleration time
• Integrated temperature monitoring of semiconductors
• Thermistor temperature monitoring of the motor
• 7.5 ... 22 kW: enclosure width 304 mm
30 ... 55 kW: enclosure width 335 mm