Timers on delayed DOLD
Показано товаров: 10 из 27
Артикул: 1325249
• According to IEC/EN 61 812-1
• 1 changeover contact
• Delay up to 60 min.
• Repeat accuracy ≤ 1 %
• LED indicator for contact position
• Devices available in 2 enclosure versions:
IK 7813: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7813: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable ducts
• Width 17.5 mm
• 1 changeover contact
• Delay up to 60 min.
• Repeat accuracy ≤ 1 %
• LED indicator for contact position
• Devices available in 2 enclosure versions:
IK 7813: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7813: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable ducts
• Width 17.5 mm
Артикул: 1325248
Артикул: 1325247
• According to IEC/EN 61 812-1
• Delay of 0.25 ... 640 s or min.
• 4 switchable time ranges
• Repeat accuracy ≤ ± 0.5 %
• Can be controlled with 2-wire initiators at terminals A1-A2,
residual current ≤ 5 mA
• Available as 2-voltage version
• Available with instantaneous contact
• 2 changeover contacts
• 2 LED displays for power supply and contact position
• Width 22.5 mm
• Delay of 0.25 ... 640 s or min.
• 4 switchable time ranges
• Repeat accuracy ≤ ± 0.5 %
• Can be controlled with 2-wire initiators at terminals A1-A2,
residual current ≤ 5 mA
• Available as 2-voltage version
• Available with instantaneous contact
• 2 changeover contacts
• 2 LED displays for power supply and contact position
• Width 22.5 mm
Артикул: 1325246
• According to IEC/EN 61 812-1
• 8 switching ranges from 0.05 s ... 16 h
• Infinite variable delay on every range 1 : 10
• Dual-voltage design as standard (e.g. AC 230 V + AC/DC 24 V)
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• 8 switching ranges from 0.05 s ... 16 h
• Infinite variable delay on every range 1 : 10
• Dual-voltage design as standard (e.g. AC 230 V + AC/DC 24 V)
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
Артикул: 1325245
• According to IEC/EN 61 812-1
• Time delay between 0.05 s ... 10 h
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled
(isolated), DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
• Time delay between 0.05 s ... 10 h
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled
(isolated), DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
Артикул: 1325244
• According to IEC/EN 61 812-1
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width
Артикул: 1325243
• According to IEC/EN 61 812-1
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width
Артикул: 1325242
• According to IEC/EN 61 812-1
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 2 changeover contacts, one programmable as instantaneous contact
• LED indicators for operation, contact position and time delay
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option connection of a remote potentiometer
• As option with time interruption / time adding input
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• 22.5 mm width
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 2 changeover contacts, one programmable as instantaneous contact
• LED indicators for operation, contact position and time delay
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option connection of a remote potentiometer
• As option with time interruption / time adding input
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• 22.5 mm width
Артикул: 1325263
• According to IEC/EN 61 812-1
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm
Артикул: 1325262
• According to IEC/EN 61 812-1
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm