Software free safety system DOLD

Показано товаров: 16 из 16
Артикул: 1324828
• For transmitting the status information from the control unit and the input
modules, e.g. input and error states, start button and safety output
assignments, to a control system or bus-capable display
• Electrical isolation
• Automatic recognition of transmission speed
• LED indicators for operating voltage and status
• Width of 45 mm
Артикул: 1324827
• For transmitting the status information from the control unit and the input
modules, e.g. input and error states, start button and safety output
assignments, to a control system or bus-capable display
• Galvanic separation
• Adjustment of transmission via rotary switch
• LED indicators for operating voltage and status
• Width 22,5 mm
Артикул: 1324826
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO contacts 0-3 s delay-release time-delay relay
- 2 NO contacts, 1 NC contact 0-3 s delay-release time-delay relay
• Permanently monitored feedback loop for external contact reinforcement
• LEDs for status indication
• Width 22.5 mm
Артикул: 1324825
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO contacts 0-3 s delay-release time-delay relay
- 2 NO contacts, 1 NC contact 0-3 s delay-release time-delay relay
• Permanently monitored feedback loop for external contact reinforcement
• LEDs for status indication
• Width 22.5 mm
Артикул: 1324824
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO contacts 0-3 s delay-release time-delay relay
- 2 NO contacts, 1 NC contact 0-3 s delay-release time-delay relay
• Permanently monitored feedback loop for external contact reinforcement
• LEDs for status indication
• Width 22.5 mm
Артикул: 1324823
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO contacts 0-3 s delay-release time-delay relay
- 2 NO contacts, 1 NC contact 0-3 s delay-release time-delay relay
• Permanently monitored feedback loop for external contact reinforcement
• LEDs for status indication
• Width 22.5 mm
Артикул: 1324822
• According to
- Performance Level (PL) d and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Input module with enabling inputs
• for connection of 2 channel
- safety gates
- e-stop buttons
- light curtain (LC) Type 4
- change over switch
- enabling swtich
• Function combination and behaviour of enabling inputs selectable on
rotary switches
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5915) or 45 mm (BH 5915)
Артикул: 1324821
• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,
autostart
- 8 E-STOP, single-channel, manual start
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +
1 signal input, manual start
- As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected.
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs per function module for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
Артикул: 1324820
• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,
autostart
- 8 E-STOP, single-channel, manual start
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start
- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +
1 signal input, manual start
- As an alternative to the 2-channel E-STOP, a light curtain
(LC type 4) according to EN 61496-1 can be connected.
• Broken wire and short circuit monitoring function with error indication
• 2 semiconductor outputs per function module for status indication
• LEDs for status indication
• Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)
Артикул: 1324819
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module mit einer per Stufenschalter einstellbarer
Combination of the following 3 functions:
- Light curtains (LC) type 4 with manual or automatic start
- E-stop 2-channel and manual or automatic start
- Two-hand function type IIIC according to DIN/EN 574
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width: 22.5 mm
Артикул: 1324818
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
· Input module for combination of 4 of the following functions to be set
via rotary switch:
- safety gate monitoring function (2 x 2 changeover contacts)
- Light curtain (LC type 4) with manual or automatic start
- Emergency stop (2-channel) with manual or automatic start
- Two-hand controls type IIIC acc. to DIN/EN 574
· Functions can be selected via rotary switches
· 8 inputs for safety sensors
· Broken wire and short circuit monitoring function with error indication
· 2 semiconductor outputs for status indication
· LEDs for status indication
· Width: 22.5 mm
Артикул: 1324817
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
· Input module for realization of
- 4 mixed 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain monitoring system (LC type 4)
· The functions are selected via rotary switch
· 8 safety inputs
· 2 semiconductor outputs for status indication
· Broken wire and short circuit monitoring function with error indication
· LEDs for status indication
· Width: 22.5 mm
Артикул: 1324816
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain (LC type 4)
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm
Артикул: 1324815
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain (LC type 4)
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm
Артикул: 1324814
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm
Артикул: 1324813
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop inputs
Outputs: 3 NO contacts, or
2 NO contacts/1 NC monitoring contact
• Parallel connection of several SAFEMASTER M-systems possible
• The functions are selected via rotary switch
- 1 Emergency stop circuit, 2-channel
- 2 Emergency stop circuits, single-channel
- 1 Emergency stop circuit, 2-channel + 1 stop single channel
• Auto or manual start
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Overvoltage and undervoltage monitoring function with error indication
• Permanently monitored feedback loop to connect external contactors
• Broken wire and short circuit monitoring function with error indication
• Width: 45 mm