Sick — . S3000 PROFINET IO Advanced, Sensor head with I/O module - S30A-7111CL - 1052595
- Direct integration in PROFINET IO safe bus system
- 7 m protective field range
- 4 switchable field sets
- Managed 2-port switch for fiber-optic connector
- Configuration memory integrated in the system plug
- Configurable system plug in I/O module
- Remote diagnostics and configuration through safety controller
- Simultaneous monitoring of 2 protective fields
Наличие
Цена
Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.
Ответим на Ваш запрос сегодня в течение дня.
Доставка
- транспортной компанией на Ваш выбор
- самовывоз из офиса в Санкт-Петербурге
- бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Коммерческие данные
Масса: 3,890 кг Страна производства: Германия Your benefits
- Reliable, fault-tolerant communication with FPLC controller using state-of-the-art fiber-optic technology.
- Efficient, cost-effective protection - networked through direct connection to PROFINET IO networks
- Rapid diagnosis by means of remote access prevents downtimes
- Standardized integration in FPLC controllers, thanks to GSDML generic station description
- Largest protective field range in the market increases the variety of application possibilities
- Quick recommissioning via configuration memory
- Easy installation, commissioning and maintenance for stationary and mobile applications
- Decades of proven safety technology guarantee maximum reliability and availability - even under difficult conditions
Функции
Number of simultaneously monitored protective fields: 2 Incremental encoder inputs: - External device monitoring (EDM): - Expanded measured data output (CMS): - Safe SICK device communication via EFI/SDL: - Технические характеристики
Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Enclosure rating: IP 65 (EN 60529) Protection class: III (VDE 0106, EN 60950) Type: Type 3 (IEC 61496) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Category: Category 3 (EN ISO 13849) Performance level: PL d (EN ISO 13849) PFHd: 8.0 * 1E-08 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Weight: 3.3 kg Scan angle: 190 ° Protective field range: 7 m Maximum warning field range: 49 m Number of field sets: 4 Type of field set: Dual field sets Number of monitoring cases: 4 Response time: 60 ms 1) Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Distance measuring range: 49 m Number of multiple samplings: Configurable 2 ... 16 Electrical connection: Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Configuration and diagnostics interface: RS-232 Device properties: GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-FX Conformance: Conformance Class B Topology support: SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support Diagnostics: Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Maintenance alerts for POF interfaces for signal quality Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Functions that are not supported: Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control footnote 1) Depending on basic response time and multiple sampling Техническая информация 1052595-S30A-7111CL.pdf
О компании Sick
SICK - ведущая мировая компания-производитель датчиков, а так же разработчик соответствующих технических решений для промышленного применения. Компания SICK предлагает передовые технологии в сфере автоматизации производства, логистики и технологических процессов. На сегодняшний день в компании работает более 6500 сотрудников в более 80 странах на всех континентах. SICK - это глобальный подход и более 65 лет опыта.
История компании1946 Зарождение компании SICK AG. Эрвин Зик получает лицензию Американского военного правительства в Мюнхене на открытие собственного инженерного офиса.
1952 Презентация на международной торговой выставке машиностроительного оборудования в Ганновере первой коммерческой световой завесы для предотвращения аварий. Заказы, ставшие результатом данного мероприятия, привели к запуску серийного производства, и стали ... Читать далее...