Sick — . IVC-2D, IVC-2D Reader - IVC-2DM1112 - 1029135
- Suitable for advanced inspections and measurements
- Flexible working distance and field of view
- Stand-alone operation, no PC needed
- IP 65 rating
- Easy-to-use interface with more than 110 software tools
- Simple interfacing with PLCs, robots and control systems that support EtherNet/IP or OPC
- Available in three different resolutions from fast VGA (0.3 MP) to high-resolution UXGA (1.9 MP)
Наличие
Цена
Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.
Ответим на Ваш запрос сегодня в течение дня.
Доставка
- транспортной компанией на Ваш выбор
- самовывоз из офиса в Санкт-Петербурге
- бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Коммерческие данные
Масса: 0,817 кг Страна производства: Германия Your benefits
- The IVC-2D’s flexibility ensures optimal setup for individual application needs
- The 1.9 MP resolution enables inspection of fine details with high repeatability
- IP 65 rating makes the system suitable for industrial environments
- Easy-to-use interface ensures fast application development, saving time and reducing costs
- The camera’s OPC server and EtherNet/IP interface enable easy integration with PLCs, robots and control systems
- Stand-alone operation reduces installation complexity compared to PC-based vision
- A wide range of camera-controlled lighting makes it easy to create a complete solution
Features
Task: Inspection Reading Measuring Positioning Technology: 2D Image analysis Snapshot Spectral range: Ca. 400 nm ... 750 nm Offline support: Emulator Sensor resolution: 640 px x 480 px, 640 px x 480 px Example field of view (H x W): See Field of view diagram Performance
Maximum performance: 30 Hz Processor: 800 MHz Image sensor: 1/3" CCD, electronic shutter Memory: 128 MB RAM, 16 MB flash Interfaces
Operator interfaces: Application specific operator interfaces can be created using ActiveX (COM) or as web page. Included OPC server enables data exchange with e.g. SCADA systems. Data store and retrieve: Images and data can be stored to and retrieved from flash and external FTP servers Digital inputs: 4 program controlled inputs (1 trigger input), HIGH = 10 V ... 28.8 V Digital outputs: 3 B-type program controlled outputs, Total output load < 100 mA, Trigger output Function (Ethernet): OPC DA Server Data transmission rate (Ethernet): 10/100 Mbit Protocol (Ethernet): TCP/IP, UDP, EtherNet/IP Configuration software: IVC Studio Serial (RS-485): 1 Mechanics/electronics
Connectors: M12, 4-pin female connector, D-coded (Ethernet) M12, 8-pin female connector (RS-485) M12, 8-pin male connector (power I/O) Supply voltage: 24 V DC± 20 % Power consumption: < 400 mA Without output load Ripple: < 5 Vpp Enclosure rating: IP 54 IP 65 with lens protection hood Housing material: Anodized aluminum Dimensions (L x W x H): 161 mm x 60 mm x 55 mm Optics: C or CS-mount Protection class: II, III Weight: 505 g Connector material: Nickel plated brass Ambient data
Shock load: 15 g, 3 x 6 directions Vibration load: 5 g, 58 Hz ... 150 Hz Ambient operating temperature 1): 0 °C ... +50 °C Ambient storage temperature 2): -20 °C ... +70 °C footnote 1) 2) Relative humidity: 35 % ... 85 %, 95 % at storage Техническая информация 1029135-IVC-2DM1112.pdf
О компании Sick
SICK - ведущая мировая компания-производитель датчиков, а так же разработчик соответствующих технических решений для промышленного применения. Компания SICK предлагает передовые технологии в сфере автоматизации производства, логистики и технологических процессов. На сегодняшний день в компании работает более 6500 сотрудников в более 80 странах на всех континентах. SICK - это глобальный подход и более 65 лет опыта.
История компании1946 Зарождение компании SICK AG. Эрвин Зик получает лицензию Американского военного правительства в Мюнхене на открытие собственного инженерного офиса.
1952 Презентация на международной торговой выставке машиностроительного оборудования в Ганновере первой коммерческой световой завесы для предотвращения аварий. Заказы, ставшие результатом данного мероприятия, привели к запуску серийного производства, и стали ... Читать далее...