  • Measurement range from 0.5 m up to 155 m on natural targets
  • Excellent accuracy thanks to time-of-flight measurement
  • Easy alignment thanks to pilot laser
  • Freely programmable parameters
  • RS-422, RS-232, PROFIBUS, analog and two switching outputs
  • Near field blanking parameter for operation through a protection window
  • Models with filter for measurement of glowing, hot metal (up to 1,400 °C)
Артикул «Первый ZIP»:143262
Артикул производителя:1027606
Доп. код производителя:DMT10-2-1213
Наличие

Наличие

Только под заказ.
Ориентировочный срок поставки: от 28 дней.
Цена

Цена

Требуется запрос производителю.

Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.

Ответим на Ваш запрос завтра 02.07.2025 в течение дня.

Этот товар не поставляется торгующим организациям. Подробнее.
Доставка

Доставка

По всей России.
  • транспортной компанией на Ваш выбор
  • самовывоз из офиса в Санкт-Петербурге
  • бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Узнайте, как мы работаем
Коммерческое предложение
Удобно для запроса одной позиции
Добавить в корзину

Товар в корзине.

Перейти в корзину
Удобно для запроса нескольких разных позиций
  • Коммерческие данные

    Масса:1,686 кг
    Страна производства:Германия

    Your benefits

    • Extremely wide measurement range of up to 155 m on natural targets offers high flexibility in applications where range is key
    • Supplementary visible alignment laser allows fast and easy alignment - even over long distances, offering fast and cost-effective installation
    • Tough metal housing design for trouble-free operation in the roughest environmental conditions
    • Non-visible, Class 1 IR laser for safe measurement and detection
    • User-friendly software with an easy-to-follow interface ensures fast and cost-optimized setup
    • Serial and analog interfaces as well as two digital switching outputs allow flexible use for varied applications
    • Integrated filter option allows for direct measurement of 1,400 °C glowing, hot targets
  • Performance

    Measurement range 1):0.5 m ... 20 m
    Resolution:≤ 1 mm
    Repeatability 2) 3) 4) 5):10 mm, 7 mm
    Accuracy 6) 7):± 10 mm
    Light source:Laser, infrared
    Typ. light spot size (distance):20 mm (+ 5 x distance in m)
    Average depth:1/16/64/256/1,024
    Aperture delay time:1 s 8)
    Note:Mechanical aperture
    Response time 9):1 ms ... 4,000 ms
    Cycle time:1,024 per sec.
    Special characteristic:Mechanical aperture
    Laser class:1 (EN 60825-1:Nov.2001, IEC 60825-1:ÄM2:2001)
    Output time:1 ms ... 4,000 ms
    footnote1) Max. object temperature 1,400 °C  2) Dependant on distance and remission, 7 mm, at 6 % ... 90 % remission from 0.5 m ... 65 m, at 6 % ... 18 % remission from 0.5 m ... 40 m, at 6 % remission from 0.5 m ... 15 m  3) 5) Environmental conditions constant, min. warm-up time 30 min, average depth 1,024, statistical error 1 σ  4) Dependant on distance and remission, 10 mm, at 6 % ... 90 % remission from 60 m ... 155 m, at 6 % ... 18 % remission from 40 m ... 65 m, at 6 % remission from 15 m ... 40 m  6) 23 °C air temperature, 977 hPa, min. warm-up time 30 min.  7) When operating in ambient temperatures between +40 °C ... +55 °C the accuracy can decrease by factor 2.5  8) Dependant on average setting, average depth, timeout, baud rate, data outpu and output format  9) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture  Dependant on average setting, average depth, timeout, baud rate, data outpu and output format  

    Interfaces

    Data interface:PROFIBUS DP
    Output type 1):Q1, Q2
    Interface for parametrization:RS-232
    Analog output:4 mA ... 20 mA, scalable
    footnote1) Output Q short-circuit protected  

    Mechanics/electronics

    Supply voltage Vs:DC 18 V ... 30 V, limit values
    Ripple 1):< 5 Vpp
    Initialization time:6 s
    Weight:Ca. 1,200 g
    Output current Ia:100 mA
    Power consumption 2):≤ 6 W
    Connection type:1 x cable gland, 1 x Sub-D, 9-pin
    footnote1) May not fall short of or exceed VS tolerances  2) Without load  

    Ambient data

    Enclosure rating:IP 65
    Protection class 1):III
    Temperature drift 2) 3):Typ. 0.3 mm/K Typ. 0.6 mm/K
    Ambient temperature:Operation with cooling case: -10 ... +75 °C Operation: -10 ... +55 °C Storage: -25 ... +70 °C
    Mechanical load:Shock: IEC 60068-2-27, -2-29 Sine: IEC 60068-2-6
    Electromagnetic compatibility (EMC):EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2
    footnote1) Reference voltage DC 50 V PELV-voltage (EN 50178)  2) -10° C ... 0° C, +40 °C … +55 °C  3) 0 °C ... +40 °C  
  • Техническая информация1027606-DMT10-2-1213.pdf

О компании Sick

Компания SICK AG, основанная в 1946 году Эрвином Сиком, является ведущим мировым производителем сенсоров и решений на их основе для промышленных применений. Штаб-квартира компании расположена в Вальдкирхе, Германия. В 2023 году SICK AG достигла оборота в 2,3 миллиарда евро и насчитывала более 12 000 сотрудников по всему миру.

Основная деятельность компании сосредоточена на разработке и производстве сенсоров для автоматизации производственных процессов, логистики и контроля технологических процессов. Продукция SICK AG находит применение в различных отраслях промышленности, включая автомобилестроение, электронику, упаковку и многие другие.

Ассортимент продукции компании включает:

Фотоэлектрические датчики: используются для детекции объектов и контроля присутствия. Индуктивные, емкостные и магнитные датчики приближения: предназначены для обнаружения ... Читать далее...