Sick — . TTK50 - TTK50-HXI0K02 - 1057792

TTK50-HXI0K02 - 1057792
Dimensional drawing
Magnetic tape
General tolerances
Wire allocation
  • Absolute, non-contact, wear-free length measurement system for linear motors
  • Measured lengths of up to 1 m
  • Suitable for high traverse speeds of up to 10 m/s
  • Reliable location positioning even in the event of condensation and contamination of the magnetic tape
  • Electronic type label and programming of the position value
  • Absolute location positioning, no reference run
  • HIPERFACE® interface
  • Conforms to RoHs
Артикул «Первый ZIP»:149406
Артикул производителя:1057792
Доп. код производителя:TTK50-HXI0K02
Наличие

Наличие

Только под заказ.
Ориентировочный срок поставки: от 28 дней.
Цена

Цена

Требуется запрос производителю.

Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.

Ответим на Ваш запрос сегодня в течение дня.

Этот товар не поставляется торгующим организациям. Подробнее.
Доставка

Доставка

По всей России.
  • транспортной компанией на Ваш выбор
  • самовывоз из офиса в Санкт-Петербурге
  • бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Узнайте, как мы работаем
Коммерческое предложение
Удобно для запроса одной позиции
Добавить в корзину

Товар в корзине.

Перейти в корзину
Удобно для запроса нескольких разных позиций
  • Коммерческие данные

    Масса:0,168 кг
    Страна производства:Германия

    Your benefits

    • Reference traverse no longer necessary due to absolute measuring system
    • Maintenance-free thanks to non-contact measuring principle
    • Simple integration of the system due to the HIPERFACE® interface
    • Developed specifically for use in linear direct drives
    • Also for use in rough ambient conditions
  • Performance

    Measuring step:0.244 µm at interpolation of the sine/cosine signals with e.g. 12 Bit
    Length of period:1 mm
    Measuring length:Max. 940 mm
    Available memory area:1,792 Byte (EEPROM 2048)
    System accuary (ambient temperature):± 10 µm (20 °C)
    Repeatability (Ta not constant):< 5 µm
    Magnetic strip length:Measurement length + 60 mm
    System part:Read head
    Measured value backlash:< 10 µm

    Механические параметры

    Dimensions:See dimensional drawing
    Mass:Read head 0.06 kg without cable, magnetic tape 0.18 kg/m
    Material:Read head die-cast zinc, magnetic tape 17410 hard ferrite 9/28 P
    Piston speed:10 m/s
    Operating speed up to which the absolute position can be rel:1.3 m/s
    Connection type:1 m

    Электрические параметры

    Electrical interface:HIPERFACE
    Operating voltage range/supply Voltage:7 V DC ... 12 V DC
    Recommended supply voltage:8 V DC
    Operating power consumption (no load):≤ 55 mA 1)
    footnote1) 100 mA approx. during adjustment  

    Interfaces

    Type of code for the absolute value:Binary
    Interface signals:Parameter channel RS 485: digital, Process data channel SIN, REFSIN, COS, REFCOS: analog, differential

    Ambient data

    Working temperature range:-30 °C ... 80 °C
    Storage temperature range:-40 °C ... 85 °C, without package
    Relative humidity / Condensation:100 %, Condensation allowed
    Resistance to shocks:30 g, 6 ms (EN 60068-2-27)
    Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
    EMC:(EN 61000-6-2) (EN 61000-6-3) 1)
    Enclosure rating:IP 65 (according to IEC 60529)
    Temperature coefficient magnetic tape:(11 ± 1) µm/K/m
    Maximum permitted ambient field strength:< 3 kA/m ... 4 kA/m (3.8 mT ... 5 mT) (to guarantee compliance with the quoted accuracy values) 2)
    Maximum permitted field strength:< 150 kA/m (< 190 mT) (to ensure that the magnetic tape is not permanently damaged)
    footnote1) The EMC according to the standards quoted is achieved when the motor feedback system which is connected to the central earthing point of the motor controller via a cable screen. Users must perform their own tests when other screen designs are used.  2) The maximum permitted external field influence is reached when the position value deviates from the original value (without external field influence) by more than 5 µm. This value is reached when, at the sensor location, a field strength of 3 kA/m to 4 kA/m (3.8 mT to 5 mT) occurs in addition to the field strength of the magnetic tape.  
  • Техническая информация1057792-TTK50-HXI0K02.pdf

О компании Sick

SICK - ведущая мировая компания-производитель датчиков, а так же разработчик соответствующих технических решений для промышленного применения. Компания SICK предлагает передовые технологии в сфере автоматизации производства, логистики и технологических процессов. На сегодняшний день в компании работает более 6500 сотрудников в более 80 странах на всех континентах. SICK - это глобальный подход и более 65 лет опыта.

История компании 

1946 Зарождение компании SICK AG. Эрвин Зик получает лицензию Американского военного правительства в Мюнхене на открытие собственного инженерного офиса.

1952 Презентация на международной торговой выставке машиностроительного оборудования в Ганновере первой коммерческой световой завесы для предотвращения аварий. Заказы, ставшие результатом данного мероприятия, привели к запуску серийного производства, и стали ... Читать далее...