Sick — . Dx100, DL100 - DL100-11AA2109 - 1060392

DL100-11AA2109 - 1060392
Dimensional drawing
Adjustment possible
Connection type supply voltage
Connection diagram power supply
Connection diagram Ethernet
Connection type CANin
Connection diagramm CANin
Connection type CANout
Connection diagramm CANout
  • Measuring range up to 220 m (dependent on type)
  • Numerous fieldbus interfaces
  • Pre-failure notification and diagnostic data available
  • Display with intuitive menu structure and clearly visible status LEDs
  • Small, rugged metal housing
  • 3-axis alignment bracket with quick-lock system as accessory available
  • Elongated holes for zero point adjustment when replacing devices
Артикул «Первый ZIP»:150309
Артикул производителя:1060392
Наличие

Наличие

Только под заказ.
Ориентировочный срок поставки: от 28 дней.
Цена

Цена

Требуется запрос производителю.

Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.

Ответим на Ваш запрос сегодня в течение дня.

Этот товар не поставляется торгующим организациям. Подробнее.
Доставка

Доставка

По всей России.
  • транспортной компанией на Ваш выбор
  • самовывоз из офиса в Санкт-Петербурге
  • бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Узнайте, как мы работаем
Коммерческое предложение
Удобно для запроса одной позиции
Добавить в корзину

Товар в корзине.

Перейти в корзину
Удобно для запроса нескольких разных позиций
  • Коммерческие данные

    Масса:1,019 кг
    Страна производства:Германия

    Your benefits

    • 100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability
    • Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C
    • The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity
    • Pre-failure notification and diagnostic data for maximum plant availability
    • Small, rugged metal housing with SpeedCon™ compatible connectors ensures smooth handling - even in confined spaces
    • Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs
  • Performance

    Measurement range:0.15 m ... 60 m, On reflective tape "Diamond Grade"
    Resolution:0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
    Repeatability 1):1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms)
    Accuracy 2):± 3 mm
    Light source 3):Laser, red
    Typ. light spot size (distance):5 mm (+ 2 mm x distance in m)
    Internal measurement cycle:1 ms
    Max. movement speed:30 m/s
    Laser class:2 (EN 60825-1 / CDRH)
    Output time:Synchronous to PLC request (dependent on interfaces)
    footnote1) Statistical error 1 σ, environmental conditions constant, depending on operating mode  2) From 150 mm ... 180 mm measuring range the accuracy can reach ± 4 mm  3) Average service life of 100,000 h at TA = +25 °C  

    Interfaces

    Data interface:CANopen
    Output type 1):B (push/pull) MF1, MF2
    Multifunctional input (MF) 2):1 x MF1
    footnote1) HIGH > VS - 3 V / LOW < 2 V  2) HIGH > 12 V / LOW < 3 V  

    Mechanics/electronics

    Supply voltage Vs:DC 18 V ... 30 V, limit values
    Ripple 1):5 Vpp
    Initialization time 2):Typ. 1.5 s
    Indication:6 digit 5 x 7 dot matrix display, LEDs
    Weight 3):Ca. 800 g ... 1,600 g
    Output current IA 4):≤ 100 mA
    Power consumption:At 24 V DC < 250 mA
    Connection type:Male connector, M12, SPEEDCON™ compatible
    Housing material:Aluminum/zinc die-cast
    Modulation frequency:Fix
    footnote1) May not fall short of or exceed VS tolerances  2) After loss of reflector < 40 ms  3) Without mounting bracket: approx. 800 g, with mounting bracket: approx. 1,600 g  4) Short circuit/overload protected. Max. 100 nF / 20 mH  

    Ambient data

    Enclosure rating:IP 65
    Protection class:III
    Effect of air pressure:0.3 ppm/hPa
    Effect of air temperature:1 ppm/K
    Temperature drift:Typ. 0.1 mm/K
    Ambient temperature 1):Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C
    Mechanical load:Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6
    Electromagnetic compatibility (EMC) 2):EN 61000-6-2 / EN 61000-6-4
    footnote1) Temperatures < -10 °C require warm-up time of typ. 7 minutes.  2) This is a Class A device. This device can cause radio interference in living quarters.  
  • Техническая информация1060392-DL100-11AA2109.pdf

О компании Sick

SICK - ведущая мировая компания-производитель датчиков, а так же разработчик соответствующих технических решений для промышленного применения. Компания SICK предлагает передовые технологии в сфере автоматизации производства, логистики и технологических процессов. На сегодняшний день в компании работает более 6500 сотрудников в более 80 странах на всех континентах. SICK - это глобальный подход и более 65 лет опыта.

История компании 

1946 Зарождение компании SICK AG. Эрвин Зик получает лицензию Американского военного правительства в Мюнхене на открытие собственного инженерного офиса.

1952 Презентация на международной торговой выставке машиностроительного оборудования в Ганновере первой коммерческой световой завесы для предотвращения аварий. Заказы, ставшие результатом данного мероприятия, привели к запуску серийного производства, и стали ... Читать далее...