Sick — . Motion Control module, Standstill Monitor - MOC3ZA-KAZ34A6 - 6047864
- Standstill monitoring by means of residual voltage measurement
- 3 normally open and 1 normally closed positively guided safety contacts
- 2 application diagnostic outputs for semiconductors
- 1 application diagnostic output normally open
- PL e (EN ISO 13849), SIL3 (IEC 61508), SILCL 3 (EN 62061)
- Maximum motor supply voltage 690 V
- Adjustable voltage threshold and standstill period
Наличие
Цена
Для уточнения цены нам необходимо связаться с производителем. Отправляйте запрос по почте, через корзину сайта или через форму заявки.
Ответим на Ваш запрос завтра 13.12.2024 в течение дня.
Доставка
- транспортной компанией на Ваш выбор
- самовывоз из офиса в Санкт-Петербурге
- бесплатная доставка до терминала “Деловые Линии” в Санкт-Петербурге
Коммерческие данные
Масса: 0,400 кг Страна производства: Германия Your benefits
- Quick mounting and installation thanks to the lack of additional wiring requirements
- Simple commissioning with a screwdriver
- Easy to retrofit as the subsequent mounting of sensors is not necessary
Safety-related parameters
Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Category: Category 4 (EN ISO 13849-1) Performance level: PL e (EN ISO 13849-1) PFHd: 41 * 1E-09 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Safe state in the event of a fault: The N/O is open; in other words, the safety-related enabling current paths are interrupted. Stop category: 1 (EN 60204-1) Механические параметры
Dimensions (W x H x D): 45 mm x 112 mm x 121 mm Weight: 400 g Mounting: 35 mm mounting rail according to EN 60715 Электрические параметры
Mechanical life: ≥ 50 * 1E 06 switching operations Contact configuration (safety contacts): 3 contacts NO, 1 contact NC Power consumption: 10 VA Supply voltage semiconductor diagnostic outputs (A3/A4): 24 V DC (11 V DC ... 30 V DC) Measurement inputs: L1/L2/L3 Measured/motor voltage: 690 V AC For UL 508 applications only: 600 V AC Voltage threshold Uan: 20 mV ... 400 mV, adjustable Standstill time ts: 0.2 s ... 6 s, adjustable Hysteresis (for detection of running motor): 100 % Response time: 100 ms Positively guided N/C contacts: Normally closed contact (41/42) Contact type: Relay, positively guided Nominal switching voltage: 250 V AC Switching capacity in accordance with AC 15: N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1) Switching capacity in accordance with DC 13: 2 A/24 V DC (EN 60947-5-1) Maximum switching frequency: 1,200 /h Contact service life at 230 V / 5 A (AC) cos φ = 0.5: ≥ 2 * 1E 05 switching operations Semiconductor application diagnostics outputs (ON, ERR): Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error Signal contacts 53/54 (normally open contact): 3 A/250 V AC G. P. Safety outputs: Normally open contact (13/14, 23/24, 33/34) Ambient data
Protection class housing: IP 40 Enclosure rating terminals: IP 20 Climate conditions according to: 25/060/04 (EN 60068-1) Vibration resistance: (EN 60068-2-6) Техническая информация 6047864-MOC3ZA-KAZ34A6.pdf
О компании Sick
SICK - ведущая мировая компания-производитель датчиков, а так же разработчик соответствующих технических решений для промышленного применения. Компания SICK предлагает передовые технологии в сфере автоматизации производства, логистики и технологических процессов. На сегодняшний день в компании работает более 6500 сотрудников в более 80 странах на всех континентах. SICK - это глобальный подход и более 65 лет опыта.
История компании1946 Зарождение компании SICK AG. Эрвин Зик получает лицензию Американского военного правительства в Мюнхене на открытие собственного инженерного офиса.
1952 Презентация на международной торговой выставке машиностроительного оборудования в Ганновере первой коммерческой световой завесы для предотвращения аварий. Заказы, ставшие результатом данного мероприятия, привели к запуску серийного производства, и стали ... Читать далее...