SITRANS P310 for differential pressure and flow Siemens

Чертеж



SITRANS P310 pressure transmitter for differential pressure and flow rate, dimensions in mm (inch)

SITRANS P310 pressure transmitters for differential pressure and flow with process covers for vertical differential pressure lines, option "H03", dimensions in mm (inch)

SITRANS P310 pressure transmitter for differential pressure and flow rate with caps for vertical differential pressure lines

Технические данные



SITRANS P310 for differential pressure and flow

 

Input

  

Measured variable

Differential pressure and flow

 

Span (fully adjustable), maximum operating pressure (pursuant to 97/23/EC Pressure Equipment Directive)

Span

Max. perm. operating pressure MAWP (PS)

 

1 ... 60 mbar
0.1 ... 6 kPa
0.4 ... 24 inH2O

160 bar
16 MPa
2320 psi

 

2.5 ... 250 mbar
0.2 ... 25 kPa
1 ... 100 inH2O

 

6 ... 600 mbar
0.6 ... 60 kPa
2.4 ... 240 inH2O

 

16 ... 1600 mbar
1.6 .... 160 kPa
6.4 ... 642 inH2O

 

50 ... 5000 mbar
5 ... 500 kPa
20 ... 2000 inH2O

 

0.3 ... 30 bar
0.03 ... 3 MPa
4.35 ... 435 psi

 

Low measuring limit

  
  • Measuring cell with silicone oil filling

-100% of max. measuring range (-33 % for 30 bar /3 MPa /435 psi measuring cell) or 30 mbar a /3 kPa a /0.44 psi a

 

Upper measuring limit

100% of maximum span

 

Start of scale

Between the measuring limits (continuously adjustable)

 

Output

  

Output signal

4 ... 20 mA

 
  • Lower limit (fully adjustable)

3.55 mA, factory preset to 3.84 mA

 
  • Upper limit (fully adjustable)

23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA

 

Load

  
  • Without HART

RB ≤ (UH - 10.5 V)/0.023 A in Ω,
UH: Power supply in V

 
  • With HART

RB = 230 ... 500 Ω (SIMATIC PDM) or
RB = 230 ... 1100 Ω (HART Communicator)

 

Protection against polarity reversal

Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage.

 

Electrical damping (step width 0.1 s)

Set to 2 s (0 ... 100 s)

 

Measuring accuracy

According to IEC 60770-1

 

Reference conditions

  • Rising characteristic curve
  • Start of scale 0 bar
  • Seal diaphragm stainless steel
  • Silicone oil filling
  • Room temperature 25 °C (77 °F)
 

Measuring span ratio r (spread, Turn-Down)

r = maximum measuring span/set measuring span

 

Error in measurement at limit setting including hysteresis and reproducibility

  
  • Linear characteristic
  
  • r ≤ 5

≤ 0.075 %

 
  • 5 < r ≤ 10

≤ (0.005 · r + 0.07) %

 
  • Square-rooted characteristic (flow > 50 %)
  
  • r ≤ 5

≤ 0.075 %

 
  • 5 < r ≤ 10

≤ (0.005 · r + 0.07) %

 
  • Square-rooted characteristic (flow 25 ... 50%)
  
  • r ≤ 5

≤ 0.15 %

 
  • 5 < r ≤ 10

≤ (0.01 · r + 0.14) %

 

Influence of ambient temperature (in percent per 28 °C (50 °F))

  
  • at -40 ... +85 °C (-40 ... +185 °F)

≤ (0.15 · r + 0.25) %

 

Effect of static pressure

  
  • on the start of scale
  
  • 60 mbar/6 kPa/0.87 psi
    250 mbar/25 kPa/3.63 psi
    600 mbar/60 kPa/8.7 psi
    1600 mbar/160 MPa/23.21 psi

≤ (0.15 · r) % per 70 bar/7 MPa/1015 psi
(zero-point correction is possible with position error adjustment)

 
  • 5 bar/500 kpa/72.5 psi
    30 bar/3 MPa/435 psi

≤ (0.2 · r) % per 70 bar/7 MPa/1015 psi
(zero-point correction is possible with position error adjustment)

 
  • on the span

≤ 0.14 % per 70 bar/7 MPa/1015 psi

 

Long-term stability (temperature change ±30 °C (±54 °F))

≤ (0.25 · r) % in 5 years, static pressure max. 70 bar/7 MPa/1015 psi

 

Effect of mounting position (in pressure per change of angle)

≤ 0.7 mbar/0.07 kPa/0.001015 psi per 10° incline (zero point correction is possible with position error compensation)

 

Effect of auxiliary power (in percent per voltage change)

0.005 % per 1 V

 

Rated conditions

  

Degree of protection acc. to IEC 60529

IP66 (optional IP66/IP68), NEMA 4X

 

Process temperature

  
  • Measuring cell with silicone oil filling

-40 ... +100 °C (-40 ... +212 °F); -20 ... +100 °C (-4 ... +212 °F) with 30 bar measuring cell

 
  • In conjunction with dust explosion protection

-20 ... +60 °C (-4 ... +140 °F)

 

Ambient conditions

  
  • ambient temperature
  
  • Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics)

-40 ... +85 °C (-40 ... +185 °F)

 
  • Display readable

-30 ... +85 °C (-22 ... +185 °F)

 
  • Storage temperature

-50 ... +85 °C (-58 ... +185 °F)

 
  • Climate class
  
  • Condensation

Relative humidity 0 ... 100 %
Condensation permissible, suitable for use in the tropics

 
  • Electromagnetic compatibility
  
  • Emitted interference and interference immunity

According to IEC 61326 and NAMUR NE 21

 

Design

  

Weight (without options)

Die-cast aluminum: ≈ 4.5 kg (≈ 9.9 lb)
Stainless steel precision casting: ≈ 7.1 kg (≈ 15.6 lb)

 

Enclosure material

Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. no. 1.4408

 

Wetted parts materials

  
  • Seal diaphragm

Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819

 
  • Process flanges and sealing screw

Stainless steel, mat. no. 1.4408, Hastelloy C4, mat. no. 2.4610

 
  • O-ring

FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR

 

Measuring cell filling

Silicone oil

 

Process connection

Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/16-20 UNF to IEC 61518

 

Material of mounting bracket

  
  • Steel

Sheet-steel, mat. no. 1.0330, chrome-plated

 
  • Stainless steel

Sheet stainless steel, mat. no. 1.4301 (SS 304)

 

Power supply UH

  

Terminal voltage on transmitter

10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsically-safe mode

 

Certificates and approvals

  

Classification according to Pressure Equipment Directive (PED 97/23/EC)

  

PN 32/160 (MAWP 464/2320 psi)

For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice)

 

PN 420 (MAWP 6092 psi)

For gases of fluid group 1 and liquids of fluid group 1; complies with basic safety requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord.

 

Explosion protection

  
  • Intrinsic safety "i"

PTB 13 ATEX 2007 X

 
  • Marking

Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb

 
  • Permissible ambient temperature

-40 ... +85 °C (-40 ... +185 °F) temperature class T4;
-40 ... +70 °C (-40 ... +158 °F) temperature class T5;
-40 ... +60 °C (-40 ... +140 °F) temperature class T6

 
  • Wiring

To certified intrinsically-safe circuits with peak values:
Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω

 
  • Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

 
  • Flameproof enclosure "d"

PTB 99 ATEX 1160

 
  • Marking

Ex II 1/2 G Ex d IIC T4/T6 Gb

 
  • Permissible ambient temperature

-40 ... +85 °C (-40 ... +185 °F) temperature class T4;
-40 ... +60 °C (-40 ... +140 °F) temperature class T6

 
  • Wiring

To circuits with operating values: UH = 10.5 ... 45 V DC

 
  • Dust explosion protection for zone 20

PTB 01 ATEX 2055

 
  • Marking

Ex II 1 D Ex ta IIIC T120 °C Da
Ex II 1/2 D Ex ta/tb IIIC T120 °C Da/Db

 
  • Perm. ambient temperature

-40 ... +85 °C (-40 ... +185 °F)

 
  • Max. surface temperature

120 °C (248 °F)

 
  • Wiring

To certified intrinsically-safe circuits with peak values:
Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω

 
  • Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

 
  • Dust explosion protection for zone 21/22

PTB 01 ATEX 2055

 
  • Marking

Ex II 2 D Ex tb IIIC T120 °C Db

 
  • Wiring

To circuits with operating values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W

 
  • Type of protection "n" (zone 2)

PTB 13 ATEX 2007 X

 
  • Marking

Ex II 2/3 G Ex nA IIC T4/T5/T6 Gc
Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc

 
  • Connection (Ex nA)

Um = 45 V

 
  • Connection (Ex ic)

To circuits with operating values:
Ui = 45 V

 
  • Effective internal inductance/capacitance

Li = 0.4 mH, Ci = 6 nF

 
  • Explosion protection to FM

Certificate of Compliance 3008490

 
  • Designation (XP/DIP) or (IS); (NI)

CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III

 
  • Explosion protection to CSA

Certificate of Compliance 1153651

 
  • Marking (XP/DIP) or (IS)

CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III

 

Communication

  

HART

230 ... 1100 Ω

 

Protocol

HART Version 5.x

 

Software for computer

SIMATIC PDM