SITRANS P310 for differential pressure and flow Siemens
Чертеж
SITRANS P310 pressure transmitter for differential pressure and flow rate, dimensions in mm (inch)
SITRANS P310 pressure transmitters for differential pressure and flow with process covers for vertical differential pressure lines, option "H03", dimensions in mm (inch)
SITRANS P310 pressure transmitter for differential pressure and flow rate with caps for vertical differential pressure lines
Технические данные
SITRANS P310 for differential pressure and flow | |||
---|---|---|---|
Input | |||
Measured variable | Differential pressure and flow | ||
Span (fully adjustable), maximum operating pressure (pursuant to 97/23/EC Pressure Equipment Directive) | Span | Max. perm. operating pressure MAWP (PS) | |
1 ... 60 mbar | 160 bar | ||
2.5 ... 250 mbar | |||
6 ... 600 mbar | |||
16 ... 1600 mbar | |||
50 ... 5000 mbar | |||
0.3 ... 30 bar | |||
Low measuring limit | |||
| -100% of max. measuring range (-33 % for 30 bar /3 MPa /435 psi measuring cell) or 30 mbar a /3 kPa a /0.44 psi a | ||
Upper measuring limit | 100% of maximum span | ||
Start of scale | Between the measuring limits (continuously adjustable) | ||
Output | |||
Output signal | 4 ... 20 mA | ||
| 3.55 mA, factory preset to 3.84 mA | ||
| 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA | ||
Load | |||
| RB ≤ (UH - 10.5 V)/0.023 A in Ω, | ||
| RB = 230 ... 500 Ω (SIMATIC PDM) or | ||
Protection against polarity reversal | Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. | ||
Electrical damping (step width 0.1 s) | Set to 2 s (0 ... 100 s) | ||
Measuring accuracy | According to IEC 60770-1 | ||
Reference conditions |
| ||
Measuring span ratio r (spread, Turn-Down) | r = maximum measuring span/set measuring span | ||
Error in measurement at limit setting including hysteresis and reproducibility | |||
| |||
| ≤ 0.075 % | ||
| ≤ (0.005 · r + 0.07) % | ||
| |||
| ≤ 0.075 % | ||
| ≤ (0.005 · r + 0.07) % | ||
| |||
| ≤ 0.15 % | ||
| ≤ (0.01 · r + 0.14) % | ||
Influence of ambient temperature (in percent per 28 °C (50 °F)) | |||
| ≤ (0.15 · r + 0.25) % | ||
Effect of static pressure | |||
| |||
| ≤ (0.15 · r) % per 70 bar/7 MPa/1015 psi | ||
| ≤ (0.2 · r) % per 70 bar/7 MPa/1015 psi | ||
| ≤ 0.14 % per 70 bar/7 MPa/1015 psi | ||
Long-term stability (temperature change ±30 °C (±54 °F)) | ≤ (0.25 · r) % in 5 years, static pressure max. 70 bar/7 MPa/1015 psi | ||
Effect of mounting position (in pressure per change of angle) | ≤ 0.7 mbar/0.07 kPa/0.001015 psi per 10° incline (zero point correction is possible with position error compensation) | ||
Effect of auxiliary power (in percent per voltage change) | 0.005 % per 1 V | ||
Rated conditions | |||
Degree of protection acc. to IEC 60529 | IP66 (optional IP66/IP68), NEMA 4X | ||
Process temperature | |||
| -40 ... +100 °C (-40 ... +212 °F); -20 ... +100 °C (-4 ... +212 °F) with 30 bar measuring cell | ||
| -20 ... +60 °C (-4 ... +140 °F) | ||
Ambient conditions | |||
| |||
| -40 ... +85 °C (-40 ... +185 °F) | ||
| -30 ... +85 °C (-22 ... +185 °F) | ||
| -50 ... +85 °C (-58 ... +185 °F) | ||
| |||
| Relative humidity 0 ... 100 % | ||
| |||
| According to IEC 61326 and NAMUR NE 21 | ||
Design | |||
Weight (without options) | Die-cast aluminum: ≈ 4.5 kg (≈ 9.9 lb) | ||
Enclosure material | Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. no. 1.4408 | ||
Wetted parts materials | |||
| Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819 | ||
| Stainless steel, mat. no. 1.4408, Hastelloy C4, mat. no. 2.4610 | ||
| FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR | ||
Measuring cell filling | Silicone oil | ||
Process connection | Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/16-20 UNF to IEC 61518 | ||
Material of mounting bracket | |||
| Sheet-steel, mat. no. 1.0330, chrome-plated | ||
| Sheet stainless steel, mat. no. 1.4301 (SS 304) | ||
Power supply UH | |||
Terminal voltage on transmitter | 10.5 ... 45 V DC | ||
Certificates and approvals | |||
Classification according to Pressure Equipment Directive (PED 97/23/EC) | |||
PN 32/160 (MAWP 464/2320 psi) | For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) | ||
PN 420 (MAWP 6092 psi) | For gases of fluid group 1 and liquids of fluid group 1; complies with basic safety requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord. | ||
Explosion protection | |||
| PTB 13 ATEX 2007 X | ||
| Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb | ||
| -40 ... +85 °C (-40 ... +185 °F) temperature class T4; | ||
| To certified intrinsically-safe circuits with peak values: | ||
| Li = 0.4 mH, Ci = 6 nF | ||
| PTB 99 ATEX 1160 | ||
| Ex II 1/2 G Ex d IIC T4/T6 Gb | ||
| -40 ... +85 °C (-40 ... +185 °F) temperature class T4; | ||
| To circuits with operating values: UH = 10.5 ... 45 V DC | ||
| PTB 01 ATEX 2055 | ||
| Ex II 1 D Ex ta IIIC T120 °C Da | ||
| -40 ... +85 °C (-40 ... +185 °F) | ||
| 120 °C (248 °F) | ||
| To certified intrinsically-safe circuits with peak values: | ||
| Li = 0.4 mH, Ci = 6 nF | ||
| PTB 01 ATEX 2055 | ||
| Ex II 2 D Ex tb IIIC T120 °C Db | ||
| To circuits with operating values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W | ||
| PTB 13 ATEX 2007 X | ||
| Ex II 2/3 G Ex nA IIC T4/T5/T6 Gc | ||
| Um = 45 V | ||
| To circuits with operating values: | ||
| Li = 0.4 mH, Ci = 6 nF | ||
| Certificate of Compliance 3008490 | ||
| CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III | ||
| Certificate of Compliance 1153651 | ||
| CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III | ||
Communication | |||
HART | 230 ... 1100 Ω | ||
Protocol | HART Version 5.x | ||
Software for computer | SIMATIC PDM |