Depending on the specification, sensors can be combined with different connection heads, neck tubes and process connections. As a result, the sensors can be used in a large number of technical applications in the following industries:

  • Chemical industry
  • Petrochemical industry
  • Power engineering
  • Basic material industry
  • Pharmaceutical industry
  • Biotechnology
  • Food manufacturing

SITRANS TS100 and SITRANS TS200

Temperature sensors of the SITRANS TS100 series come with different electrical connection options (e.g. plug, soldered connections, connection cables)

The SITRANS TS200 series features a compact design. Both temperature sensors are suitable for the following:

  • Measurements of temperatures of solids, where additional protective tubes are not required for replacements done during ongoing operations, e.g. bearing block temperature.
  • Measurements which are particularly critical with regard to response times. The advantages offered by an additional protective tube are purposely omitted.
  • Measuring points which can be easily converted or which must be able to change locations.
  • Surface temperature measurements: The temperature sensor is used in conjunction with a surface connection piece.
  • Cost-effective transport: The mineral-insulated design of the sensors
  • allows for economically feasible transport even at large lengths. Starting with a length of 1 m, sensors are supplied in rolls.

SITRANS TS500 Temperature sensors as a module system

Due to their modular design, temperature sensors of the SITRANS TS500 series are well suited to a large number of applications.

The replaceable measuring insert makes it possible to conduct maintenance work even during ongoing operations. These devices are used particularly frequently in pipelines and tanks the following industries:

  • Power stations
  • Chemical industry
  • Petrochemical industry
  • General process engineering
  • Water, waste water

Обзор



Photo Product Family

Temperature sensors of the SITRANS TS product family are used to measure temperatures in industrial equipment.

Siemens offers the following temperature sensors:

  • SITRANS TS100
    • general use
    • Compact design with connection cable
  • SITRANS TS200
    • general use
    • Compact design with plug/non-flexible wire ends
  • SITRANS TS500
    • general use
    • modular design with connection head and protective tube

Дизайн



SITRANS TS100 7MC711xx

The following image illustrates the available designs for SITRANS TS100 temperature sensors:

SITRANS TS100 cable temperature sensor, sensor, plastic-sheathed cable design (MIC)

The following types of process connections can be implemented:

  • Compression joint
  • Spring-mounted compression joint
  • Soldering nipple
  • Direct soldering/welding in

SITRANS TS200 7MC712xx

The following image illustrates the available designs for SITRANS TS200 temperature sensors:

SITRANS TS basic sensor

The following types of process connections can be implemented:

  • Compression joint
  • Spring-mounted compression joint
  • Soldering nipple
  • Direct soldering/welding in

SITRANS TS500 7MC75xx

The following image illustrates the available designs for SITRANS TS500 temperature sensors:

SITRANS TS500

The temperature sensors of the SITRANS TS500 series are available in three different designs:

Version

Description

Application

Process connection

1

  • Protective sleeve made of pipe material
  • Protective sleeve and extension made of one pipe;
  • closed off with a welded bottom cap at the tipgrn

Minimal to medium process requirements

  • Connected with thread or flange
  • Thread is welded on, or compression joint

2

  • Protective sleeve made of solid material
  • Protective sleeve made of solid material, extension made of piping material; extension screwed into protective sleeve

Medium to highest process requirements

  • Directly welded into pipeline
  • With welded flange
  • With male thread

3

  • For installation into existing protective sleeves.
  • Extension made of piping material

Process requirements dependent on protective sleeve design

Screwed into existing protective sleeve.



Функции



A complete measuring point consists of a measuring insert which contains the basic sensors, the protective fitting and an optional measurement value processor (transmitter).

The basic sensors are:

  • Resistance thermometers:
    Temperature measurement is based on the temperature dependency of the installed measuring resistor.
  • Thermocouples:
    Temperature measurement is based on the Seebeck effect. A thermocouple which subjected to a temperature drop produces thermoelectric voltage that can be measured.

Transmitters:

The optional Siemens transmitters assume the following functions:

  • Optimum measurement processing
  • Strengthen weak sensor signals directly on site.
  • Transmit standardized signals
  • Protect against electromagnetic interspersion
  • Option to conduct measuring point diagnostics.

Конфигурация



Configuration

Components: Process connections

This catalog is limited to the standard versions. Special versions are available on request.

Welding

A welded protective tube provides a permanent, secure and highly resilient process connection, assuming a respective welding quality.

It is not possible to accidentally open the ... Additional gaskets are not required. If the pipe is not thick enough to ensure a secure welding connection, the appropriate weldable sockets are used.

Weldable sockets

Thread

Type of installation: Screw socket

Screw sockets of different thread types and sizes are firmly welded to the protective tube.

Screw socket

Type of installation: Compression joints

Compression joints are available as accessories. They fit with the diameter of the protective tube and provide for flexible installation. The mounting length can be selected on site. When installed correctly, compression joints are well suited for low and medium pressure.

The difference between a normal and spring-mounted design is as follows:

In the case of spring-mounted compression joints, the sensor is pressed against the measured object or the floor of the protective tube, thus achieving particularly strong heat contact.

Compression joint

Spring-mounted compression joint

Thread type: Cylindrical thread

Cylindrical threads do not seal in the thread but due to an additional sealing face or seal. For example, threads with the short form "G" (as per ISO 228) feature a threat type with a defined screw gauge.

Cylindrical thread

The male threads of our G½ screw sockets fit with both female G½ as well as Rp½ threads.

Thread type: Tapered thread

Tapered threads are different in that they seal metallically in the thread. For example, the American "NPT". Differently from the cylindrical threads, tapered threads such as the American "NPT" seal metallically in the thread itself. The relevant length information in the catalog refers to the "torque point" of the thread, which cannot be precisely defined due to standardized tolerance levels. However, the spring unit of the measuring insert compensates for the differences in length.

NPT thread

Flanges

The different properties of the flanges are as follows:

  • Standard series EN 1092, ASME 16.5,..
  • Nominal pressure
  • Nominal diameter
  • Sealing face

This information is also stamped into the flange, along with the material code and batch number for "3.1 Material".st

Industry-specific process connections

Special process connections have become popular in different industries. For example, hygiene technology: clamp-on connections, milk pipe unions and others.

Components: Protective tube

Protective tubes or sleeves fulfill two basic functions:

  • they protect the measuring insert from aggressive media
  • they make it possible to replace units during ongoing operations

This catalog is limited to the standard versions. Special versions are available on request. The large number of available types can be classified as follows:

  • Protective tubes made of piping material
    Protective tubes made of piping material are also described as "welded" or "multi-part" protective tubes. They are suitable for low to medium process loads and can be manufactured on a cost-effective basis.
    Versions :
    • Form 2N similar to DIN 43772
      with straight tip and shortest possible extension length
      non-alignable connection head
    • Form 2 as per DIN 43772
      with straight tip and extension
      alignable connection head
    • Form 2: with process connection
      Form 2G: Threaded connection
      Form 2F: Flange connection
    • Form 3 as per DIN 43772
      Design with tapered tip and extension
      alignable connection head
      For these protective tubes, the protective tube tip is tapered by hammering. This results in an excellent fit with the measuring insert and very good response times.
      Analogous to forms 2, versions 3/3G/3F are also available for 3
  • Protective tubes made of solid materials
    Where process loads are too great, or where a protective tube cannot have a welded seam, deep hole drilled protective sleeves made of solid materials are used. Form 4 protective tubes (as per DIN 43772) are very popular in this area.

The following table shows the dimensions of the different protective tubes.

 

Tip

Process connection

∅ Inner [mm (inch)]

∅ Outer [mm (inch)]

∅ Inner [mm (inch)]

∅ Outer [mm (inch)]

Protective tube type, design

D1

D2

D3

D4

2N/2/2G/2F, pipe

7

9

7

9

2/2G/2F, pipe

7

12

7

12

3/3G/3F, pipe

6 + 0,1, 0,05

9

7

12

4/4F, Full

7

12,5

7

24

4/4F, fast response, full

3,5

9

3,5

18



Components: Extension

The extension is the section from the lower edge of the connection head to the fixed point of the process connection or protective tube. There are a variety of terms for this components, e.g. neck tube. For this reason the term extension has been selected as a standardized term for the different designs. Function is the deciding factor:

  • Thermal decoupling of connection head from process temperature
  • Installation of connection head over existing insulation
  • Simple standardization of measuring inserts: In general, the length of the extension may be freely selected. However, when using standardized mounting lengths, the option "Extension as per DIN 43 772" is recommended. This ensures that measuring inserts which are quickly available can be used. In the case of special lengths, it is possible to standardize the measuring insert length through a clever combination with the respective special extension length. This allows customers to optimize their costs in purchasing and logistics.
  • In the case of American-designed sensors, the extension also takes the spring load of the measuring unit.
  • Depending on the design, the extension can also be used to achieve an alignment of the connection head.
  • The form of the extension depends on the form of the protective tube:
    • Protective tube made of piping material
      The extension and protective tube usually consist of one continuous tube. The process connection is welded on. (= one-piece protective fitting).
    • Protective tubes made of solid materials
      Extension and protective tube consist of two components which are welded together. The process connection is attached to the protective tube (= multi-piece protective fitting).

Protective tube type

X [mm (inch)]

M[mm] (inch)

Divisible

2G

129 (5.08)

145 (5.71)

No

2F

64 (2.52)

80 (3.15)

No

3G

131 (5.19)

147 (5.79)

No

3F

66 (2.60)

82 (3.23)

No

4 (only L=110)

139 (5.47)

155 (6.10)

Yes

4 (others)

149 (5.87)

165 (6.50)

Yes



Extensions as per DIN 43772

Versions

With regard to their function, extensions can be classified into two types:

  • Alignable/non-alignable Ability to align connection head to the desired direction
  • Integrated measuring insert spring load In the case of American-type sensors, the spring load of the measuring insert is integrated into the extension. Measuring insert and extension form one unit.

alignable

cylindrical

alignable

tapered

without neck tube

without thread

   

non-alignable

cylindrical

non-alignable

tapered

non-alignable

Nipple

   

alignable

Nipple-Union-Nipple

alignable

Nipple-Union-Nipple

spring load

non-alignable

Nipple-Union-Nipple

spring load

   


Versions

Components: Connection head

Connection head

the connection head protects the connection department. The connection head features sufficient room for mounting a clamping base or transmitter.

Different connection heads are used depending on the application and preference:

Connection head

Type/Material

Designation

Degree of protection

Transmitter installation

Connection height

Explosion protection optional

 

BA0: Aluminum

Flange lid

IP54

Measuring insert

25 mm (0.98 inch)

Ex i

 

BB0: Aluminum

Hinged cover low

IP 65

Measuring insert

25 mm (0.98 inch)

Ex i

 

BC0: Aluminum

BC0: Plastic

Hinged cover high

IP 65

Measuring insert and/or hinged cover

25 mm (0.98 inch)

Ex i

 

BM0: Plastic

Screw cover

IP 65

Measuring insert

25 mm (0.98 inch)

Ex i

 

AG0: Aluminum

AU0: Stainless steel

Screw cover, heavy-duty

IP 68

Measuring insert

41 mm (1.61 inch)

Ex i, Ex d

 

AH0: Aluminum

AV0: Stainless steel

Screw cover, sight glass, heavy-duty

IP 68

Measuring insert

41 mm (1.61 inch)

Ex i, Ex d



Components: Measuring insert

Measuring insert

The measuring insert of the temperature sensor is built into the protective fitting (protective tube, extension and connection head). The basic sensor is located in the measuring insert, where it is protected. The spring load of the Siemens measuring inserts provide good thermal contact with the floor of the protective tube, and vibration resistance is significantly increased. Only highly resistant mineral-insultaed cables (MIC or plastic-sheathed) are used for the electrical connection between the basic sensor and connection head. The highly compacted magnesium oxide insulation achieves excellent vibration resistance. The following measuring insert designs are the most popular on the world market:

  

European type

American type



European type

European type measuring inserts can be replaced without having to dismantle the connection head. The springs are located either on the transmitter or the terminal block. This makes it possible to achieve a 8 to 10 mm spring range. Instead of a ceramic head, you can also mount a SITRANS-TH transmitter directly on the blank of the measuring insert.

American type

American-type measuring inserts feature a large spring range. These measuring inserts are ideal for use with NPT threads that feature high tolerances. In this configuration, the extension function is partially or fully integrated (nipple-union-nipple). Moreover it is also possible to directly attach field devices, e.g. SITRANS-TF.

Components: Transmitters

SITRANS-TH head transmitters process weak non-linear sensor signals and transmit a stable and temperature-linear standard signal, thereby minimizing sensor signal disruptions.

The transmitters permanently monitor the temperature sensors and transmit diagnostic data to superordinate systems.

Because of the low energy feed of the SITRANS-TH head transmitters, self-heating of the temperature sensors can be maintained at minimal levels.

The electrical isolation and integrated cold junction ensure that temperature sensors with thermocouples provide reliable measurements at a low cost.

SITRANS-TH product family

  • TH100 - the basic device
    • Output 4..20mA
    • for PT100
    • can be configured using simple software
  • TH200 - the universal device
    • Output 4..20mA
    • Resistance thermometer, thermocouples
    • can be configured using simple software
  • TH300 - HART universal
    • Output 4..20mA/HART
    • Resistance thermometer, thermocouples
    • HART conforming
    • Diagnostic functions
  • TH400 - Fieldbus PA and FF
    • Output PROFIBUS PA or FOUNDATION Fieldbus
    • Resistance thermometer, thermocouples
    • Diagnostics

Installation types

All SITRANS-TH transmitters can be installed in type B connection heads. The following installation forms are used:

  • Measuring insert installation
    Our standard version offers the following advantages
    • Small vibrating masses and compact design
    • Measuring insert-transmitter unit can be replaced quickly

Installation of measuring insert

  • Hinged cover installation
    • Standard for head type BC0 and BP0
    • Advantage: Measuring insert and transmitter can be repaired/maintained separately (recalibration).

Hinged cover installation

Measuring technology: Basic sensors

The diverse application spectrum for industrial temperature measuring technology requires different sensor technologies.

Resistance thermometer

The Pt100 resistance thermometers in this catalog correspond with IEC 751/EN 60 751.

Basic sensors made of other basic materials, with different basic values or different underlying standards are available on request. Resistance thermometers can be classified as follows

  • Basic design
    The sensor element is built with thin layer technology. The resistance material is applied in the form of a thin layer on a ceramic carrier material.
  • Versions featuring increased vibration resistance
    In addition to the basic design: Measures to improve vibration resistance.
  • Versions with expanded measuring range
    Elements in wire-wound design. The wire winding is embedded in a ceramic body.

Thermocouples

The thermocouples in this catalog correspond with IEC 584/EN 60 584.

Other thermocouples based on other thermo pairs or underlying standards are available upon request.

The most common ignoble thermocouples are:

  • Type N (NiCrSi-NiSi) high degree of stability even in upper temperature range.
  • Type K (NiCr-Ni) more stable than type J, but drifts in upper range.
  • Type J (Fe-CuNi) narrow application band.

Measuring technology: Measuring range

The measuring area describes the temperature limits within which the thermometer can be used in a way that is meaningful for measurement purposes. Depending on the loads present and the desired accuracy levels, the actual application range for the thermometer may be smaller.

Resistance thermometer

Basic version and increased vibration resistance

-50 ... 400 °C (-58 ... 752 °F)

Expanded measuring range

-200 ... 600 °C (-328 ... 1112 °F)



Thermocouple

Type N

-40 ... 1100 °C (-40 ... 2112 °F)

Type K

-40 ... 1000 °C (-40 ... 1132 °F)

Type J

-40 ... 750 °C (-40 ... 1382 °F)



Measuring technology: Measuring accuracy

Resistance thermometer

The tolerance classes of the resistance thermometers correspond with IEC 751/EN 60751:

tolerance

Δt

Basic accuracy, Class B

±(0.30 °C+0.0050|t|)

Increased accuracy, Class A

±(0.15 °C+0.0020|t|)

High degree of accuracy, Class 1/3 B

±(0.10 °C+0.0017|t|)



The following tables provide an overview of the scope of these tolerances. If you exceed the specified limits with a resistance thermometer, the values of the next lower accuracy class apply:

Resistance thermometer
Basic version

tolerance

Range

Basic accuracy,
Class B

-50 °C ... 400 °C (-58 ... 752 °F)

Increased accuracy,
Class A

-50°C..300°C (-58 ... 572 °F)

High degree of accuracy
Class AA (1/3 B)

0°C..150°C (32 ... 302 °F)



Resistance thermometer
Increased vibration resistance

tolerance

Range

Basic accuracy,
Class B

-50 °C ... 400 °C (-58 ... 752 °F)

Increased accuracy,
Class A

-50°C..300°C (-58 ... 572 °F)

High degree of accuracy
Class AA (1/3 B)

0°C..150°C (32 ... 302 °F)



Resistance thermometer
Expanded measuring range

tolerance

Range

Basic accuracy,
Class B

-196 °C ... 600 °C (392 ... 1112 °F)

Increased accuracy,
Class A

-196 °C ... 600 °C (392 ... 1112 °F)



Depending on the thermal and mechanical loads at the site, the actual application range of the thermometer may be smaller.

Thermocouples

The tolerance classes of the thermocouples correspond with IEC 584/EN 60584:

Catalog versions

Type

Basic accuracy, Class 2

Increased accuracy, Class 1

N

-40 °C ... 333 °C±2,5 °C
(-40 °F ... 631.4 °F±4.5 °F)
333 °C ... 1200 °C±0,0075 x |t| (631.4 °F ... 2192 °F±0.0075 x |t|)

-40 °C ... 375 °C±2,5 °C
(-40 °F ... 707 °F±2.7 °F)
375 °C ... 1000 °C±0,004 x |t| (707 °F ... 1832 °F±0.004 x |t|)

K

-40 °C ... 333 °C±2,5 °C
(-40 °F ... 631.4 °F±4.5 °F)
333 °C ... 1200 °C±0,0075 x |t| (631.4 °F ... 2192 °F±0.0075 x |t|)

-40 °C ... 375 °C±2,5 °C
(-40 °F ... 707 °F±2.7 °F)
375 °C ... 1000 °C±0,004 x |t| (707 °F ... 1832 °F±0.004 x |t|)

J

-40 °C ... 333 °C±2,5 °C
(-40 °F ... 631.4 °F±4.5 °F)
333 °C ... 750 °C±0,0075 x |t| (631.4 °F ... 1382 °F±0.0075 x |t|)

-40 °C ... 375 °C±2,5 °C
(-40 °F ... 707 °F±4.5 °F)
375 °C ... 750 °C±0,004 x |t| (707 °F ... 1382 °F±0.004 x |t|)



Other thermocouples, ignoble

Type

Basic accuracy, Class 2

Increased accuracy, Class 1

T

-40 °C ... 133 °C±1 °C
(-40 °F ... 271.4 °F±1.0 °F)
133 °C ... 350 °C±0,0075 x |t| (271.4 °F ... 662 °F±0.0075 x |t|)

-40 °C ... 125 °C±0,5 °C
(-40 °F ... 257 °F±0.9 °F)
125 °C ... 350 °C±0,004 x |t| (257 °F ... 662 °F±0.004 x |t|)

E

-40 °C ... 333 °C±2,5 °C
(-40 °F ... 631.4 °F±4.5 °F)
333 °C ... 900 °C±0,0075 x |t| (631.4 °F ... 1652 °F±0.0075 x |t|)

-40 °C ... 375 °C±1,5 °C
(-40 °F ... 707 °F±2.7 °F)
375 °C ... 800 °C±0,004 x |t| (707 °F ... 1472 °F±0.004 x |t|)



Other thermocouples, noble

Type

Basic accuracy, Class 2

Increased accuracy, Class 1

R and S

0 °C ... 600 °C±1,5 °C
(32 °F ... 1112 °F±2.7 °F)
600 °C ... 1600 °C±0,0025 x |t| (1112 °F ... 2912 °F±0.0025 x |t|)

0 °C ... 1100 °C±1 °C
(32 °F ... 2012 °F±1.8 °F)
1100 °C ... 1600 °C±[1 + 0,003 (t - 1100)] °C (2112 °F ... 2912 °F±[1.8 + 0.003 (t - 212)] °F)

B

600 °C ... 1700 °C±0,0025 x |t|
(1112 °F ... 3092 °F±0.0025 x |t|)

 


Measuring technology: Response times

Response time describes the speed of the measurement system in the case of a temperature change, and is typically indicated as T0.5 or T0.9. The values indicate the time in which a measured value has increased to 50% or 90% of the actual temperature increase.

The main variables which affect response time are as follows:

  • Protective tube geometry Ideally:
    as little material as possible at tip, use of conductive material
  • Thermal connection of measuring insert to protective tube:
    Because of design changes implemented for the measuring insert (small gap width, spring system), Siemens measuring inserts feature very good response behavior. Because of the good fit, additional contact materials are not usually required except in certain applications e.g. attachment of a surface sensor.
  • Size of temperature increase
  • Medium and flow rate

Resistance thermometer

Typical values as per EN 60751 in water at 0.4m/s can be found in the following table.

Protective tube form

Diameter [mm]

T0.5

T0.9

None

6 mm (0.24 inch)

3 mm (0.12 inch)

3,9

1

11,4

3,5

straight (2)

9 mm (0.35 inch)

12 mm (0.47 inch)

30

23

96

69

Tapered (3)

12 mm (0.47 inch)

10

24

Solid material (4)
U=65

24 mm (0.95 inch)

27

77

Solid material (4)]
U=125

24 mm (0.95 inch)

30

85

Solid material (4)
U=65

18 mm (0.71 inch)

19

52



Thermocouples

Typical values as per EN 60751 in water at 0.4m/s can be found in the following table.

Protective tube form

Diameter [mm]

T0.5

T0.9

None

6 mm (0.24 inch)

3 mm (0.12 inch)

2

0,5

4

1

straight (2)

9 mm (0.35 inch)

12 mm (0.47 inch)

20

19

63

66

Tapered (3)

12 mm (0.47 inch)

7

22

Solid material (4)
U=65

24 mm (0.95 inch)

22

73

Solid material (4)]
U=125

24 mm (0.95 inch)

20

53

Solid material (4)
U=65

18 mm (0.71 inch)

12

41



Measuring technology: Mounting depth

Measuring insert

Type

Temperature-sensitive length (TSL) [mm]

Non-bendable length [mm]

Basic

7 mm (0.28 inch)

30 mm (1.82 inch)

Increased vibration resistance

7 mm (0.28 inch)

30 mm (1.82 inch)

Expanded measuring range

50 mm (1.97 inch)

60 mm (2.36 inch)

Thermocouple

3 mm (0.12 inch)

3 mm (0.12 inch)



Contact with media

Ambient conditions (temperature/weather/insulation) and the size of the protective tube, process connection and piping result in so-called "heat transmission errors".

To prevent such an error, the submersion depth and diameter of the protective tube tip are defined. The temperature-sensitive length (TSL) of the protective tube must also be taken into account.

  • Water
    Submersion depth ≥ TSL + 5 x Ø of protective tube
  • Air
    Submersion depth ≥ TSL + 10..15 x Ø of protective tube
  • Recommendations
    • Select largest possible submersion depth
    • Select measuring location with higher flow velocity
    • Insulate outer components of thermometer
    • Smallest possible surface for outer components
    • Installation in pipe bends, left
    • Direct measurements without additional protective tube if no suitable solution can be found using other measures.

Measuring technology: Connection types

In the case of resistance thermometers, the type of sensor connection directly affects the level of accuracy:

Two-wire system

The resistance of sensor lines are included in the measurement result as an error. Adjustments are recommended in this case.

PT100 2-wire system

Three-wire system

Line resistance is not included in the measurement result. Requirements: all terminal and line resistances (corrosion) are at the same level, and terminals are at the same temperature level.

PT100 three-wire system

Four-wire system

Line resistance is not included in the measurement result. This type of connection is the most secure and most accurate.

PT100 four-wire system

Siemens measuring inserts can be used to implement all types of connections for 1 x Pt100 devices. In the case of 2 x Pt100 versions, two- and three-wire systems are also possible. For measurement-related reasons, we always recommend a 1 x four-wire or 2 x 3-wire connection.

Temperature influence

At the connection head

 

without transmitter

with transmitter

Aluminum or stainless steel

-40 ... 150 °C
(-40 ... 302 °F)

-40 ... 85 °C
(-40 ... 185 °F)

Plastic

-40 ... 85 °C
(-40 ... 185 °F)

-40 ... 85 °C
(-40 ... 185 °F)



Influence of extension

The illustration below assists you in selecting the right length for the neck tube.

length of neck tube, effect on temperature

Please note that guidance values may change due to local conditions. Please consider these potential changes particularly with respect to explosion protection.

Also note that the accuracy of the transmitter also depends on the temperature in the connection head.

Process connection/Protective tube

When selecting a process connection, process parameters of a certain technology can be considered along with regional, standard-based and customer-specific requirements. The range of products includes a broad selection of standard connections. Additional products are available on request.

In the case of redesigned or newly designed facilities, it is possible to achieve cost savings by implementing various measures:

  • Use of standard lengths through clever selection of screw, weld or flange sockets
  • Moveable compression joints

The temperature resistance of a material for process connections and protective tubes also limits the application area of the temperature sensor. The temperature range indicated on the type plate always refers to the measuring insert, not the material which comes into contact with media. Two aspects must be considered when assessing temperature stability:

  • What maximum temperature may the material reach without a load?
  • What is the behavior under load?

Process load

Because of the large variety of possible applications and variables, it is not possible to make general binding statements regarding the resilience of components which comes into contact with media. The load diagrams below can be used for common application areas. However, where operating conditions vary significantly, please contact our technical support team.

Possible variables affecting measuring accuracy:

The process itself

Correction options

Temperature

Mounting lengths

Pressure

Protective tube type

Flow velocity

Material selection (incl. coating)

Viscosity

Suitable process connection

Vibration

Support against vibration

Corrosiveness

 

Abrasion (e.g. carbon dust)

 


Load diagrams

Protective tubes with Ø9.1 mm(0.36 inch) ,measurements in mm (inch)

Protective tubes with Ø12 x 2.5 mm (0.47 X 0.10 inch), measurements in mm (inch)

Protective tubes with Ø12 x 2.5 mm (0.47 X 0.10 inch), Ø14 x 2.5 mm (0.55 X 0.10 inch), measurements in mm (inch)

Protective tubes with Ø14 mm (0.95 inch), C= 65 mm (2.60 inch), measurements in mm (inch)

Protective tubes with Ø18 mm (0.71 in), C= 65 mm (2.60 inch), measurements in mm (inch)

Protective tubes with Ø14 mm (0.95 inch), C= 4.92 in (4.92 in), measurements in mm (inch)

Protective tube calculation

Properly applied load diagrams will provide a sufficient degree of safety for the most common protective tube configurations.

However, there are cases in which operating conditions excessively deviate from standard parameters. In this case a customized protective tube calculation may be required.

Запрос коммерческого предложения

×

    * Поля, обязательные для заполнения.

    Сообщение отправлено

    ×

    В ближайшее время сообщение будет обработано.

    Письмо с номером обращения отправлено на Ваш почтовый ящик.

    Спасибо за то, что выбрали Первый ZIP!

    Что-то пошло не так...

    ×

    К сожалению, наша система расценила Ваше сообщение как спам.

    Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

    Приносим извинения за возможные неудобства.