Motor Modules Booksize Cabinet Kits format Siemens
Обзор
Motor Modules are also available as Booksize Cabinet Kits in voltage class 380 V to 480 V (DC link voltage 510 V to 720 V).
The following Motor Modules are available:
- Single Motor Modules for power ratings of 1.6 kW to 107 kW to connect a motor
- Double Motor Modules for power ratings of 1.6 kW to 9.7 kW to connect two motors
Дизайн
Motor Modules booksize format are installed in the factory as Booksize Cabinet Kits in Booksize Base Cabinets. This complete unit contains all of the components necessary for operation.
Motor Modules booksize format are installed in the factory as Booksize Cabinet Kits in Booksize Base Cabinets. This complete unit contains all of the components necessary for operation.
Each Motor Module is connected separately to the DC busbar of the SINAMICS S120 Cabinet Module via a separate fuse switch disconnector with integrated fuses. The DC connecting busbar integrated in the units is not used.
The basic version of the Booksize Cabinet Kit comprises the following components:
- Motor Module, booksize format
- Fuse switch disconnector for each Motor Module installed
- Customer interface -X55.1 located in the connection area of the Booksize Base Cabinet
- Shield connection plate
- Complete electrical connection to the Booksize Base Cabinet interfaces
Whereas Single Motor Modules have one inverter connection, Double Motor Modules combine two inverters in a single module. For each Double Motor Module that is installed in a Booksize Cabinet Kit, the customer interface, the motor connection and in some cases also options for separate control, are provided twice and shown in the option selection table.
The Booksize Base Cabinets can be operated up to and including IP54 degree of protection without additional temperature derating. However, some values need to be taken into account that differ from those of the chassis format. Derating data, see the System overview → Characteristic curves.
Интеграция
Connection example: Single Motor Module, Booksize Cabinet Kit format
Connection example: Double Motor Module, Booksize Cabinet Kit format
Опции
The table below lists the options available for Motor Modules in the Booksize Cabinet Kit format as well as the Booksize Base Cabinets (Details → Description of the options):
Available options | Order code | Booksize Cabinet Kits | Booksize Base Cabinet |
---|---|---|---|
CBC10 Communication Board | G20 | ✓ 1) | – |
CBE20 Communication Board | G33 | ✓ 1) | – |
Safety license for 1 to 5 axes | K01 to K05 | ✓ | – |
AOP30 Advanced Operator Panel installed in the cabinet door | K08 | ✓ 1) | – |
SMC10 Sensor Module Cabinet-Mounted | K46 | ✓ 2) | – |
SMC20 Sensor Module Cabinet-Mounted | K48 | ✓ 2) | – |
SMC30 Sensor Module Cabinet-Mounted | K50 | ✓ 2) | – |
VSM10 Voltage Sensing Module | K51 | ✓ 2) | – |
Terminal module for controlling the Safe Torque Off and Safe Stop 1 safety functions | K82 | ✓ 2) | – |
TM54F Terminal Module | K87 | ✓ | – |
CU320-2 DP Control Unit | K90 | ✓ | – |
Performance expansion for CU320-2 Control Unit | K94 | ✓ 1) | – |
CU320-2 PN Control Unit | K95 | ✓ | – |
Motor reactor | L08 | ✓ 2) | – |
2 motor reactors in series (not available for Double Motor Modules) | L09 | ✓ | – |
DC interface incl. pre-charging circuit of the associated DC link capacitance | L37 | ✓ | – |
Cabinet anti-condensation heating | L55 | – | ✓ |
Base 100 mm high, RAL 7022 | M06 | – | ✓ |
Cable-marshalling space 200 mm high, RAL 7035 | M07 | – | ✓ |
IP21 degree of protection | M21 | – | ✓ |
IP23 degree of protection (includes M60) | M23 | – | ✓ |
Side panel mounted at the right | M26 | – | ✓ |
Side panel mounted at the left | M27 | – | ✓ |
IP43 degree of protection (includes M60) | M43 | – | ✓ |
IP54 degree of protection (includes M60) | M54 | – | ✓ |
Closed cabinet door, air intake from below through floor opening | M59 | – | ✓ |
EMC shield bus | M70 | – | ✓ |
DC busbar system (Id = 1170 A, 1 × 60 × 10 mm) | M80 | – | ✓ |
DC busbar system (Id = 1500 A, 1 × 80 × 10 mm) | M81 | – | ✓ |
DC busbar system (Id = 1840 A, 1 × 100 × 10 mm) | M82 | – | ✓ |
DC busbar system (Id = 2150 A, 2 × 60 × 10 mm) | M83 | – | ✓ |
DC busbar system (Id = 2730 A, 2 × 80 × 10 mm) | M84 | – | ✓ |
DC busbar system (Id = 3320 A, 2 × 100 × 10 mm) | M85 | – | ✓ |
DC busbar system (Id = 3720 A, 3 × 80 × 10 mm) | M86 | – | ✓ |
DC busbar system (Id = 4480 A, 3 × 100 × 10 mm) | M87 | – | ✓ |
Crane transport assembly (top-mounted) | M90 | – | ✓ |
Special paint finish for cabinet | Y09 | – | ✓ |
Factory assembly as transport units | Y11 | – | ✓ |
One-line label for system identification, 40 × 80 mm | Y31 | – | ✓ |
Two-line label for system identification, 40 × 180 mm | Y32 | – | ✓ |
Four-line label for system identification, 40 × 180 mm | Y33 | – | ✓ |
Customer documentation (circuit diagram, terminal diagram, layout diagram) in DXF format | D02 | – | ✓ 1) |
Preliminary version of customer documentation in PDF format | D14 | – | ✓ 1) |
Documentation in English/French | D58 | – | ✓ |
Documentation in English/Spanish | D60 | – | ✓ |
Documentation in English/Italian | D80 | – | ✓ |
Without Operating Instructions | D99 | – | ✓ |
Rating plate data in English/French | T58 | – | ✓ |
Rating plate data in English/Spanish | T60 | – | ✓ |
Rating plate data in English/Italian | T80 | – | ✓ |
Visual acceptance | F03 | – | ✓ |
Function test without connected motor | F71 | – | ✓ |
Insulation test | F77 | – | ✓ |
Customer-specific acceptance inspections (on request) | F97 | – | ✓ |
1) Only together with option K90 or K95.
2) In the case of the Double Motor Modules, these options are available for each inverter.
Option selection matrix for Booksize Cabinet Kits and Booksize Base Cabinets
Certain options can mutually exclude one another
(options that are not involved are not shown).
✓ | Possible combination |
---|---|
– | Combination not possible |
Electrical options Booksize Cabinet Kits
| G20 | G33 | K46 | K48 | K50 | K51 | K90 | K95 | L08 | L09 |
---|---|---|---|---|---|---|---|---|---|---|
G20 |
| – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
G33 | – |
| ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
K46 | ✓ | ✓ |
| – | – | – | ✓ | ✓ | ✓ | ✓ |
K48 | ✓ | ✓ | – |
| – | – | ✓ | ✓ | ✓ | ✓ |
K50 | ✓ | ✓ | – | – |
| – | ✓ | ✓ | ✓ | ✓ |
K51 | ✓ | ✓ | – | – | – |
| ✓ | ✓ | ✓ | ✓ |
K90 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| – | ✓ | ✓ |
K95 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – |
| ✓ | ✓ |
L08 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| – |
L09 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – |
|
Mechanical options for Booksize Base Cabinets
| M06 | M07 | M21 | M23 | M26 | M27 | M43 | M54 | M90 | Y11 | Y31 | Y32 | Y33 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M06 |
| – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
M07 | – |
| ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
M21 | ✓ | ✓ |
| – | ✓ | ✓ | – | – | ✓ | ✓ | ✓ | ✓ | ✓ |
M23 | ✓ | ✓ | – |
| ✓ | ✓ | – | – | ✓ | ✓ | ✓ | ✓ | ✓ |
M26 | ✓ | ✓ | ✓ | ✓ |
| – | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
M27 | ✓ | ✓ | ✓ | ✓ | – |
| ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
M43 | ✓ | ✓ | – | – | ✓ | ✓ |
| – | ✓ | ✓ | ✓ | ✓ | ✓ |
M54 | ✓ | ✓ | – | – | ✓ | ✓ | – |
| ✓ | ✓ | ✓ | ✓ | ✓ |
M90 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| – | ✓ | ✓ | ✓ |
Y11 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – |
| ✓ | ✓ | ✓ |
Y31 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| – | – |
Y32 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – |
| – |
Y33 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | – | – |
|
DC busbar system mechanical options (busbars between individual Cabinet Modules)
| M80 | M81 | M82 | M83 | M84 | M85 | M86 | M87 |
---|---|---|---|---|---|---|---|---|
M80 |
| – | – | ✓ | – | – | – | – |
M81 | – |
| – | – | ✓ | – | ✓ | – |
M82 | – | – |
| – | – | ✓ | – | ✓ |
M83 | ✓ | – | – |
| – | – | – | – |
M84 | – | ✓ | – | – |
| – | ✓ | – |
M85 | – | – | ✓ | – | – |
| – | ✓ |
M86 | – | ✓ | – | – | ✓ | – |
| – |
M87 | – | – | ✓ | – | – | ✓ | – |
|
Documentation
| D02 | D14 | D58 | D60 | D80 | D99 |
---|---|---|---|---|---|---|
D02 |
| ✓ | ✓ | ✓ | ✓ | – |
D14 | ✓ |
| ✓ | ✓ | ✓ | – |
D58 | ✓ | ✓ |
| – | – | – |
D60 | ✓ | ✓ | – |
| – | – |
D80 | ✓ | ✓ | – | – |
| – |
D99 | – | – | – | – | – |
|
Rating plate data
| T58 | T60 | T80 |
---|---|---|---|
T58 |
| – | – |
T60 | – |
| – |
T80 | – | – |
|
Технические данные
Line voltage 380 … 480 V 3 AC DC link voltage 510 … 720 V DC | Single Motor Modules Booksize Cabinet Kit | ||||
---|---|---|---|---|---|
| 6SL3720-1TE13-0AB3 | 6SL3720-1TE15-0AB3 | 6SL3720-1TE21-0AB3 | 6SL3720-1TE21-8AB3 | |
Type rating | |||||
| kW | 1.6 | 2.7 | 4.8 | 9.7 |
| kW | 1.4 | 2.3 | 4.1 | 8.2 |
| hp | 1.5 | 3 | 5 | 10 |
| hp | 1 | 2 | 5 | 10 |
Output current | |||||
| A | 3 | 5 | 9 | 18 |
| A | 2.3 | 4.3 | 7.7 | 15.3 |
| A | 6.0 | 10.0 | 18.0 | 36.0 |
DC link current Id 4) | A | 3.6 | 6 | 11 | 22 |
Current demand | |||||
| A | 0.85 | 0.85 | 0.85 | 0.85 |
DC link capacitance | μF | 110 | 110 | 110 | 220 |
Pulse frequency 5) | |||||
| kHz | 4 | 4 | 4 | 4 |
| |||||
| kHz | 16 | 16 | 16 | 16 |
Power loss, max. 6) | |||||
| kW | 0.035 | 0.055 | 0.08 | 0.165 |
| kW | 0.035 | 0.055 | 0.08 | 0.165 |
Cooling air requirement | m3/s | 0.008 | 0.008 | 0.008 | 0.008 |
Sound pressure level LpA (1 m) at 50/60 Hz | dB | < 60 | < 60 | < 60 | < 60 |
Motor connection U2, V2, W2 |
| Terminal | Terminal | Terminal | Terminal |
| mm2 | 6 | 6 | 6 | 6 |
Cable length, max. 7) | |||||
| m | 50 |
Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |