D-R 320 dust measuring instrument Siemens
![](https://pzip.ru/Images/Siemens/cat/P_PA10_XX_00176i.jpg)
Область применения
The D-R 320 monitors not only the efficiency of the filter plants by registering the residual dust content, but also reports instantaneously when permissible levels of dust or flue gas emissions are exceeded. As a result it is often possible to intervene directly in the process of the plant to be monitored and thus ensure reliable compliance with the specified limit values.
Areas of application
Continuous emission monitoring, for example, on:
- Incineration plants in general
- Plants according to IED 2010/75/EU/17. BImschV
- Plants according to 2001/80/EG LCPD/13. BImschV/German TA-Luft
- Waste, hazardous waste and sewage sludge incineration plants
- Cement manufacturing plants
- Power plants with gas, oil, coal or co-firing
- Plants for the incineration of biomass
Monitoring of:
- Ventilation units
- Filter units
Approvals
- Suitability-tested by the TÜV Cologne, test report 936/21217455/A
- Certified according to DIN EN 15267-3
Обзор
The D-R 320 is an optical dust monitor for the smallest to medium dust concentrations in dry emissions and process gas.
Дизайн
System components D-R 320
Transmitter / receiver unit D-R 320 M
The transmitter and receiver optics are integrated together with the electronics in a compact unit in a rugged housing. The transmission-reception unit consists of the measuring head, the swivel adapter, the process connection and the field facing panel. This measuring unit is installed directly above the waste gas duct, on a DIN 100 PN 6 or ANSI 4" 150 lbs flange. No adjustment is required.
Supply unit D-TB 200
The supply unit of the dust concentration measuring instrument D-R 320 is used to supply electricity and purge air and provides the connection for the transfer of the measured data. The regulated purge air is used to keep clean the optical interfaces of the transmission and reception optics of the D-R 320. The device automatically reports any failure of the purging air.
Optional:
Universal control unit D-ISC 100
The connected equipment can be operated and configured conveniently using the D-ISC 100. The display provides an immediate overview of the current measured values and the status of the measuring instruments.
Measured-value acquisition
In the simplest case the measured values and reference values are transferred to the plant''s control system. The measured values and status signals that are sent can also be fed to an emission calculator system for further processing, either via discrete signals (4 to 20 mA and configurable relay contacts) or via Modbus according to VDI 4201-3.
Quick-closing shutter
The swivel adapter can be optionally replaced with an adapter with a fully integrated quick-closing shutter. By using this quick-closing shutter the path between the measuring device and the waste gas is closed mechanically, but not airtight in the event of a fault (failure of power supply or purge air); the measuring device is temporarily protected against overheating in such cases. The measuring head takes over the control of the quick-closing shutter.
Weather protection covers
A weather protection cover is available to protect the measuring system when it is installed outdoors.
Explosion proof design
An explosion proof design with pressurized enclosure according to EEx p, Zone 1 or Zone 2 is available for use in hazardous areas.
Функции
The device operates according to the backscattering principle. The light of a laser diode illuminates the dust particles in the measuring volume of the flue gas duct. The light reflected by the particles is measured and evaluated.
The D-R 320 does not require a light trap. The background light in the stack is detected by means of a special optical system with an integrated dual detector and automatically compensated without manual adjustment.
The universal control unit D-ISC 100 can be connected for the measured value display, which allows up to eight dust and flow-rate measurement instruments.
The connected equipment can be operated and configured conveniently using the D-ISC 100. The display provides an immediate overview of the current measured values and the status of the measuring instruments.
Control functions
The D-R 320 automatically performs zero and span check as well as contamination check at regular intervals and on demand. The device features an automatic contamination correction. Need for maintenance is immediately indicated by the electronics.
Особенности
- Continuous measurement of dust concentration
- Easy installation on standard flanges
- Easy setup without manual adjustment
- Automatic background light compensation, no light trap
- Convenient operation, remote access option
- Automatic control functions
- Integrated purge air regulation and purge air control
- Long maintenance intervals
- Certified to EN 15267-3
- Data transmission via Modbus, in compliance with VDI 4201-3
Технические данные
Measuring head | |
Measured variable | Dust concentration |
Measuring ranges | 0 ... 5 mg/m3 to 0 ... 200 mg/m3 |
Measuring principle | Backscattering |
Sample gas temperature | 0 ... 600 °C |
Sample gas pressure | -50 ... +50 hPa, optional higher |
Duct diameter | 0.7 ... 20 m |
Ambient temperature | -40 ... +60 °C |
Degree of protection | IP65 |
Measured value outputs | 0/4 ... 20 mA, 400 Ω |
Digital outputs | 2 relay outputs, permissible load 60 VDC, 30 V AC / 0.5 A |
Digital inputs | None |
Auxiliary power | 24 VDC/0.5 A |
Dimensions (H x W x D) | 200 x 190 x 260/410 mm |
Weight | 15 kg |
Supply box | |
Purge air supply | Integrated blower |
Supply voltage | 115/230 V AC, 50/60 Hz, 0.37/0.43 kW |
Dimensions (H x W x D) | 480 x 450 x 320 mm |
Weight | 12 kg |
Degree of protection | IP65 |
Дальнейшая информация
Please consult your Siemens sales partner for information on how to correctly configure and order a D-R 320 measuring instrument for a Siemens CEMS project.