1-phase, 24 V DC Siemens
![](https://pzip.ru/Images/Siemens/cat/P_KT01_XX_01338i.jpg)
Обзор
The one-phase SITOP smart are the universal and powerful standard power supplies for machinery and plant engineering. Despite their compact design, they offer an excellent overload response: Thanks to a power boost of 150 %, loads with high power consumption can be connected without any problems and the permanent overload capability of 120% offers power reserves in case of expansions. The high degree of efficiency results in low energy consumption and minimal heat generation inside the control cabinet.
To further increase 24 V availability, the SITOP smart power supplies can be combined with buffer, DC UPS, redundancy and selectivity modules.
Main product highlights
- 1-phase, 24 V DC/2.5 A, 5 A, 10 A and 20 A
- Input voltage 120 V and 230 V AC with automatic range switching
- Compact design - no lateral clearances required
- Extra power with 1.5 times the rated current (5 s/min) for brief functional overload
- Permanent overload capability with 1.2 times the rated current up to 45 °C ambient temperature
- Adjustable output voltage for compensating voltage drops
- Signaling contact for easy integration in the plant monitoring system
- Wide temperature range from -25 or -10 to +70 °C
- Comprehensive certifications, such as cULus, ATEX and GL
Технические данные
Order number | 6EP1332-2BA20 | 6EP1333-2BA20 | 6EP1334-2BA20 | 6EP1336-2BA10 | |
---|---|---|---|---|---|
Product | SITOP PSU100S | SITOP PSU100S | SITOP PSU100S | SITOP PSU100S | |
Power supply, type | 24 V/2.5 A | 24 V/5 A | 24 V/10 A | 24 V/20 A | |
Input |
|
|
|
| |
Input | 1-phase AC | 1-phase AC | 1-phase AC | 1-phase AC | |
Supply voltage |
|
|
|
| |
| 120 V | 120 V | 120 V | 120 V | |
| 230 V | 230 V | 230 V | 230 V | |
| Automatic range selection | Automatic range selection | Automatic range selection | Automatic range selection | |
Input voltage |
|
|
|
| |
| 85 ... 132 V | 85 ... 132 V | 85 ... 132 V | 85 ... 132 V | |
| 170 ... 264 V | 170 ... 264 V | 170 ... 264 V | 176 ... 264 V | |
Wide-range input | No | No | No | No | |
Overvoltage resistance | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | 2.3 × Vin rated, 1.3 ms | |
Mains buffering at Iout rated, min. | 20 ms; at Vin = 93/187 V | 20 ms; at Vin = 93/187 V | 20 ms; at Vin = 93/187 V | 20 ms; at Vin = 120/230 V | |
Rated line frequency | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | 50 ... 60 Hz | |
Rated line range | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz | 47 ... 63 Hz | |
Input current |
|
|
|
| |
| 1.25 A | 2.34 A | 4.49 A | 7.5 A | |
| 0.74 A | 1.36 A | 1.91 A | 3.5 A | |
Switch-on current limiting (+25 °C), max. | 33 A | 40 A | 60 A | 11 A | |
I²t, max. | 0.4 A²·s | 1 A²·s | 5.6 A²·s | 10 A²·s | |
Built-in incoming fuse | T 3,15 A/250 V (not accessible) | T 3,15 A/250 V (not accessible) | T 6.3 A/250 V (not accessible) | T 10 A (not accessible) | |
Protection in the mains power input (IEC 898) | Recommended miniature circuit breaker: from 3 A characteristic C | Recommended miniature circuit breaker: from 6 A characteristic C | Recommended miniature circuit breaker: from 10 A characteristic C | Recommended miniature circuit breaker: from 10 A characteristic C or circuit-breaker 3RV2411-1JA10 (120 V) or 3RV2411-1FA10 (230 V) | |
Output |
|
|
|
| |
Output | Controlled, isolated DC voltage | Controlled, isolated DC voltage | Controlled, isolated DC voltage | Controlled, isolated DC voltage | |
Rated voltage Vout DC | 24 V | 24 V | 24 V | 24 V | |
Total tolerance, static ± | 3 % | 3 % | 3 % | 3 % | |
Static mains compensation, approx. | 0.1 % | 0.1 % | 0.1 % | 0.5 % | |
Static load balancing, approx. | 1 % | 1 % | 1 % | 1 % | |
Residual ripple peak-peak, max. | 150 mV | 150 mV | 150 mV | 150 mV | |
Residual ripple peak-peak, typ. | 30 mV | 30 mV | 20 mV | ||
Spikes peak-peak, max. (bandwidth: 20 MHz) | 240 mV | 240 mV | 240 mV | 240 mV | |
Spikes peak-peak, typ. (bandwidth: 20 MHz) | 70 mV | 140 mV | 160 mV | ||
Adjustment range | 22.8 ... 28 V | 22.8 ... 28 V | 22.8 ... 28 V | 24 ... 28 V | |
Product function Output voltage adjustable | Yes | Yes | Yes | Yes | |
Output voltage setting | via potentiometer | via potentiometer | via potentiometer | via potentiometer; max. 480 W | |
Status display | Green LED for 24 V OK | Green LED for 24 V OK | Green LED for 24 V OK | Green LED for 24 V OK | |
Signaling | Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK" | Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK" | Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK" | Relay contact (NO contact, rating 50 V DC/ 0.3 A) for "24 V OK" | |
On/off behavior | Overshoot of Vout < 3 % | Overshoot of Vout < 3 % | Overshoot of Vout < 3 % | No overshoot of Vout (soft start) | |
Startup delay, max. | 0.3 s | 0.3 s | 0.3 s | 1.5 s | |
Voltage rise, typ. | 15 ms | 15 ms | 20 ms | 50 ms | |
Voltage increase time of the output voltage maximum | 500 ms | ||||
Rated current value Iout rated | 2.5 A | 5 A | 10 A | 20 A | |
Current range | 0 ... 3 A | 0 ... 6 A | 0 ... 12 A | 0 ... 20 A | |
| 3 A up to +45°C; +60 ... +70 °C: Derating 3%/K | 6 A up to +45°C; +60 ... +70 °C: Derating 1.6%/K | 12 A up to +45°C; +60 ... +70 °C: Derating 3%/K | 24 A up to +45°C; +60 ... +70 °C: Derating 5%/K | |
Active power supplied typical | 60 W | 144 W | 288 W | 480 W | |
Short-term overload current |
|
|
|
| |
| 9 A | 18 A | 32 A | 35 A | |
| 9 A | 18 A | 32 A | 35 A | |
Duration of overloading capability for excess current |
|
|
|
| |
| 100 ms | 800 ms | 1 000 ms | 100 ms | |
| 800 ms | 800 ms | 1 000 ms | 100 ms | |
Parallel switching for enhanced performance | Yes | Yes | Yes | Yes | |
Numbers of parallel switchable units for enhanced performance | 2 | 2 | 2 | 2 | |
Efficiency |
|
|
|
| |
Efficiency at Vout rated, Iout rated, approx. | 85 % | 88 % | 90 % | 90 % | |
Power loss at Vout rated, Iout rated, approx. | 10 W | 16 W | 25 W | 53 W | |
Closed-loop control |
|
|
|
| |
Dynamic mains compensation (Vin rated ±15 %), max. | 0.3 % | 0.3 % | 0.3 % | 1 % | |
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ. | 3 % | ||||
Dynamic load smoothing (Iout: 10/90/10 %), Uout ± typ. | 5 % | 3 % | 3 % | ||
Load step setting time 10 to 90%, typ. | 1 ms | 1 ms | 1 ms | ||
Load step setting time 90 to 10%, typ. | 1 ms | 1 ms | 1 ms | ||
Setting time maximum | 10 ms | ||||
Protection and monitoring |
|
|
|
| |
Output overvoltage protection | protection against overvoltage in case of internal fault Vout < 33 V | protection against overvoltage in case of internal fault Vout < 33 V | protection against overvoltage in case of internal fault Vout < 33 V | Yes, according to EN 60950-1 | |
Current limitation | 3 ... 3.4 A | 6 ... 7.1 A | 12 ... 14.6 A | ||
Current limitation, typ. | 21 A | ||||
Property of the output Short-circuit proof | Yes | Yes | Yes | Yes | |
Short-circuit protection | Constant current characteristic | Constant current characteristic | Constant current characteristic | Electronic shutdown, automatic restart | |
Enduring short circuit current RMS value |
|
|
|
| |
| 7 A | ||||
| 3.4 A | 7.1 A | 14.6 A | ||
Overcurrent overload capability in normal operation | overload capability 150 % Iout rated up to 5 s/min | overload capability 150 % Iout rated up to 5 s/min | overload capability 150 % Iout rated up to 5 s/min | overload capability 150 % Iout rated up to 5 s/min | |
Overload/short-circuit indicator | - | - | - | - | |
Safety |
|
|
|
| |
Primary/secondary isolation | Yes | Yes | Yes | Yes | |
Galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | |
Protection class | Class I | Class I | Class I | Class I | |
Leakage current |
|
|
|
| |
| 3.5 mA | 3.5 mA | 3.5 mA | 3.5 mA | |
| 0.4 mA | 0.4 mA | 0.8 mA | 1 mA | |
CE mark | Yes | Yes | Yes | Yes | |
UL/CSA approval | Yes | Yes | Yes | Yes | |
UL/cUL (CSA) approval | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604) | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; in preparation: cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) | |
Explosion protection | ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2007) Class I, Div. 2, Group ABCD, T4 | ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T4 | |
Certificate of suitability IECEx | No | No | No | No | |
Certificate of suitability NEC Class 2 | No | No | No | No | |
FM approval | - | - | - | - | |
CB approval | Yes | Yes | Yes | Yes | |
Marine approval | Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |