SIDOOR AT12 elevator door drive Siemens
Область применения
The comfort SIDOOR AT12 elevator door drive is an intelligent door control system which enables the opening and closing of cabin and shaft doors at adjustable speeds and accelerations.
The maintenance-free, variable speed drive unit comprises a DC motor with non-self-locking gearing. The SIDOOR M2 geared motor (24 V DC/1.8A; motor for max. total door leaf weight of 120 kg) must be ordered separately → see"Geared motors".
Operation of the door drive does not require a limit switch. The door width and the "OPEN"/"CLOSE" positions are determined automatically.
The current operating states are indicated via an LED with a flashing code integrated in the SIDOOR AT12 Elevator Door Drive or externally via a Service Tool → see"Additional units".
Power transmission is via a toothed belt which passes over a guide pulley and which can be fitted with two door clutch holders. These accessories are not included in the scope of delivery → see "Accessories".
This enables handling of both one-sided and centrally opening doors.
Обзор
SIDOOR AT12 Elevator Door Drive
SIDOOR AT12 – SIDOOR enables the quick, easy and versatile installation, configuration and operation of a wide range of elevator door systems.
- For dynamic door weights up to 120 kg
- 4 kg maximum counterweight
- Operating temperature 0 to +50 °C
- Opening width 0.3 to 2.4 m
- Integrated switch mode power supply
- Auxiliary voltage output 24 V DC, 120 mA (short circuit proof)
- CANopen interface (integrated in the controller)
- Degree of protection IP20
- The current operating states are indicated via an LED with a flashing code integrated in the SIDOOR AT12 elevator door drive or externally via the Service Tool, seeAdditional units.
Дизайн
The SIDOOR AT12 Elevator Door Drive system consists of a number of components:
Version | Type | See |
---|---|---|
Controller | ||
SIDOOR AT12 elevator door drive | 6FB1111-1AT20-1AT1 | |
The following individual components must be ordered separately: | ||
Additional units | "Additional units" | |
| 6FB1105-0AT01-6SW0 | |
| 6FB1105-0AT01-6ST0 | |
DC geared motors | "Geared motors" | |
| ||
| 6FB1103-0AT10-5MA0 | |
| 6FB1103-0AT11-5MA0 | |
Accessories for the complete system | "Accessories" | |
| ||
| 6FB1104-0AT02-0AD0 | |
| ||
| 6FB1104-0AT01-0AS0 | |
| 6FB1104-0AT02-0AS0 | |
| 6FB1104-0AT01-0CP0 | |
| 6FB1104-0AT03-0AS0 | |
| ||
| 6FB1104-0AT01-0AB0 | |
| 6FB1104-0AT02-0AB0 |
Конфигурация
During initial commissioning, please note the following:
- For mechanical installation and configuration, see
- "SIDOOR AT12 Elevator Door Drive" Manual, http://support.automation.siemens.com/WW/view/en/58497029
- "SIDOOR AT12 Elevator Door Drive – Manufacturer-Specific CANopen Objects" Compact User Manual, http://support.automation.siemens.com/WW/view/en/59004938
- Electrical configuration and commissioning:
- Push the door into the "CLOSED" position.
- Plug in the motor connector
- Plug in the power plug
- Press and hold the learn run button
- Switch on line voltage
- The learn run starts automatically; the learn run button can be released when the door starts moving.
- On completion of the learn run, the door is in the "CLOSED" position and the LED shows a steady green light.
- Briefly press the learn run button to open the door fully.
- Press the button again when the door is in its "OPEN" end position to fully close the door.
Особенности
- 1-button operation for the entire commissioning process
- Optimum and stable drive characteristics
- Reduced service requirements and costs
- SIDOOR User Software (part of the Software Kit, not included in the scope of delivery → see "Additional units") enables user-friendly operation and detailed diagnostics.
- Small footprint thanks to compact design
- Automated functions for enhanced safety
Програмирование
The Software Kit is available as an additional unit (see "Additional units") and allows quick and easy updating of the firmware using the Siemens HCS12 Firmware Loader.
User-friendly parameter setting and oscilloscope function is carried out via the SIDOOR User Software (part of the Software Kit).
Технические данные
Order number |
| 6FB1111-1AT20-1AT1 | |
---|---|---|---|
General technical data: |
|
| |
product brand name |
| SIDOOR | |
Product designation |
| Door controller | |
Design of the product |
| AT12 | |
Supply voltage: |
|
| |
Supply voltage at AC | V | 230 | |
Supply voltage frequency at AC | Hz | 50 ... 60 | |
Operating current of fuse protection at input when installing |
| 6 ... 10 | |
Consumed current maximum | A | 10 | |
I2t value minimum | A²·s | 30 | |
Active power consumption |
|
| |
| W | 80 | |
| W | 160 | |
| W | 3 | |
Inputs/ Outputs: |
|
| |
Input voltage per DC input | V | 10 ... 28 | |
Input current per DC input | mA | 6 ... 18 | |
Product property |
|
| |
|
| Yes | |
|
| Yes | |
Output voltage at DC | V | 24 | |
Output current at 24 V DC output maximum | mA | 120 | |
Property of the 24 V DC output |
|
| |
|
| CAUTION: Do not supply with external voltage! | |
|
| Yes | |
|
| Yes | |
Switching capacity current of the output relay at DC at 30 V | A | 0.01 ... 0.5 | |
Door-relevant data: |
|
| |
Door opening width | m | 0.3 ... 2.4 | |
Weight of door maximum | kg | 120 | |
Counterweight |
|
| |
| kg | 4 | |
Ambient conditions: |
|
| |
Ambient temperature |
|
| |
| °C | 0 ... 50 | |
| °C | -20 ... +85 | |
Protection class IP |
| IP20 | |
Installation/ mounting/ dimensions: |
|
| |
Width | mm | 260 | |
Height | mm | 45 | |
Depth | mm | 105 | |
Standards: |
|
| |
Type of test TÜV prototype tested |
| Yes | |
Certificate of suitability |
|
| |
|
| Yes | |
|
| Yes | |
Standard for EMC |
| EN 12015 / EN 12016 | |
Standard for safety |
| EN 60950-1:2006 |