SIDOOR AT12 elevator door drive Siemens

Область применения



The comfort SIDOOR AT12 elevator door drive is an intelligent door control system which enables the opening and closing of cabin and shaft doors at adjustable speeds and accelerations.

The maintenance-free, variable speed drive unit comprises a DC motor with non-self-locking gearing. The SIDOOR M2 geared motor (24 V DC/1.8A; motor for max. total door leaf weight of 120 kg) must be ordered separately → see"Geared motors".

Operation of the door drive does not require a limit switch. The door width and the "OPEN"/"CLOSE" positions are determined automatically.

The current operating states are indicated via an LED with a flashing code integrated in the SIDOOR AT12 Elevator Door Drive or externally via a Service Tool → see"Additional units".

Power transmission is via a toothed belt which passes over a guide pulley and which can be fitted with two door clutch holders. These accessories are not included in the scope of delivery → see "Accessories".

This enables handling of both one-sided and centrally opening doors.

Обзор



SIDOOR AT12 Elevator Door Drive

SIDOOR AT12 – SIDOOR enables the quick, easy and versatile installation, configuration and operation of a wide range of elevator door systems.

  • For dynamic door weights up to 120 kg
  • 4 kg maximum counterweight
  • Operating temperature 0 to +50 °C
  • Opening width 0.3 to 2.4 m
  • Integrated switch mode power supply
  • Auxiliary voltage output 24 V DC, 120 mA (short circuit proof)
  • CANopen interface (integrated in the controller)
  • Degree of protection IP20
  • The current operating states are indicated via an LED with a flashing code integrated in the SIDOOR AT12 elevator door drive or externally via the Service Tool, seeAdditional units.

Дизайн



The SIDOOR AT12 Elevator Door Drive system consists of a number of components:

Version

Type

See

Controller

SIDOOR AT12 elevator door drive
(with integrated switch-mode power supply)

6FB1111-1AT20-1AT1

 

The following individual components must be ordered separately:

Additional units
that enable universal implementation and maintenance of the door drive system

 

"Additional units"

  • Software Kit

6FB1105-0AT01-6SW0

 
  • Service Tool

6FB1105-0AT01-6ST0

 

DC geared motors

 

"Geared motors"

  • SIDOOR M2 geared motors (max. door weight 120 kg)
  
  • SIDOOR M2 L (pinion left)

6FB1103-0AT10-5MA0

 
  • SIDOOR M2 R (pinion right)

6FB1103-0AT11-5MA0

 

Accessories for the complete system
see also overview diagram → "For elevators"

 

"Accessories"

  • Rubber-metal anti-vibration mounts
    for low-noise operation of the door drive system
  
  • for the SIDOOR M2 geared motor

6FB1104-0AT02-0AD0

 
  • Mounting bracket
  
  • for the SIDOOR M2 geared motor
    for flexible accommodation of the rubber-bonded metal

6FB1104-0AT01-0AS0

 
  • for the deflector unit
    for setting the toothed belt to the required tension

6FB1104-0AT02-0AS0

 
  • Door clutch holder
    for connecting a door leaf to the toothed belt

6FB1104-0AT01-0CP0

 
  • Deflector unit
    for the toothed belt STS, for attaching to the door system

6FB1104-0AT03-0AS0

 
  • Toothed belt STS
    as a connection between the door system and the end positions of the door
  
  • Length 4 m

6FB1104-0AT01-0AB0

 
  • Length 45 m

6FB1104-0AT02-0AB0

 


Конфигурация



During initial commissioning, please note the following:

  • For mechanical installation and configuration, see
  • Electrical configuration and commissioning:

    • Push the door into the "CLOSED" position.
    • Plug in the motor connector
    • Plug in the power plug
    • Press and hold the learn run button
    • Switch on line voltage
    • The learn run starts automatically; the learn run button can be released when the door starts moving.
    • On completion of the learn run, the door is in the "CLOSED" position and the LED shows a steady green light.
    • Briefly press the learn run button to open the door fully.
    • Press the button again when the door is in its "OPEN" end position to fully close the door.

Особенности


  • 1-button operation for the entire commissioning process
  • Optimum and stable drive characteristics
  • Reduced service requirements and costs
  • SIDOOR User Software (part of the Software Kit, not included in the scope of delivery → see "Additional units") enables user-friendly operation and detailed diagnostics.
  • Small footprint thanks to compact design
  • Automated functions for enhanced safety

Програмирование



The Software Kit is available as an additional unit (see "Additional units") and allows quick and easy updating of the firmware using the Siemens HCS12 Firmware Loader.

User-friendly parameter setting and oscilloscope function is carried out via the SIDOOR User Software (part of the Software Kit).

Технические данные



Order number

 

6FB1111-1AT20-1AT1

General technical data:

 

 

product brand name

 

SIDOOR

Product designation

 

Door controller

Design of the product

 

AT12

Supply voltage:

 

 

Supply voltage at AC

V

230

Supply voltage frequency at AC

Hz

50 ... 60

Operating current of fuse protection at input when installing

 

6 ... 10

Consumed current maximum

A

10

I2t value minimum

A²·s

30

Active power consumption

 

 

  • Rated value

W

80

  • Rated value maximum

W

160

  • in standby mode Rated value

W

3

Inputs/ Outputs:

 

 

Input voltage per DC input

V

10 ... 28

Input current per DC input

mA

6 ... 18

Product property

 

 

  • Isolated control inputs

 

Yes

  • Control inputs switching to P potential

 

Yes

Output voltage at DC

V

24

Output current at 24 V DC output maximum

mA

120

Property of the 24 V DC output

 

 

  • Note

 

CAUTION: Do not supply with external voltage!

  • Short-circuit proof

 

Yes

  • with overload withstand capability

 

Yes

Switching capacity current of the output relay at DC at 30 V

A

0.01 ... 0.5

Door-relevant data:

 

 

Door opening width

m

0.3 ... 2.4

Weight of door maximum

kg

120

Counterweight

 

 

  • for geared motor SIDOOR M2 maximum

kg

4

Ambient conditions:

 

 

Ambient temperature

 

 

  • during operation

°C

0 ... 50

  • during storage

°C

-20 ... +85

Protection class IP

 

IP20

Installation/ mounting/ dimensions:

 

 

Width

mm

260

Height

mm

45

Depth

mm

105

Standards:

 

 

Type of test TÜV prototype tested

 

Yes

Certificate of suitability

 

 

  • acc. to EN 81

 

Yes

  • CE marking

 

Yes

Standard for EMC

 

EN 12015 / EN 12016

Standard for safety

 

EN 60950-1:2006


Дальнейшая информация



For further product details, refer to the