SIDOOR ATD400K cold room gate drive Siemens

Область применения



The SIDOOR ATD400K Cold Room Gate Drive is an intelligent door control system which enables cold room gates to be opened and closed at adjustable speeds and accelerations.

The maintenance-free, variable speed drive unit comprises a DC motor with non-self-locking gearing.

Two different motors are available:

  • SIDOOR M3 geared motor (30 V DC/4.0 A; motor for max. overall door leaf weight of 180 kg, degree of protection IP40)
  • SIDOOR M4 geared motor (30 V DC/4.0 A; motor for max. overall door leaf weight of 400 kg, degree of protection IP40)

They must be ordered separately, see "Geared motors".

Operation of the door drive does not require a limit switch. The door width and the "OPEN"/"CLOSE" positions are determined automatically.

The current operating states are indicated by a 7‑segment display directly in the SIDOOR ATD400K Cold Room Gate Drive. They can also be displayed externally with the aid of the Software Kit or Service Tool, see "Additional Units".

Power transmission is via a toothed belt, which passes over a deflector unit and can be fitted with two door clutch holders. The accessory parts are not included in the scope of supply, see "Accessories".

This enables handling of both one-sided and centrally opening doors.

Обзор



SIDOOR ATD400K cold room gate drive

The SIDOOR ATD400K Cold Room Gate Drive enables the quick, easy and versatile installation, configuration and operation of a wide range of cold room gate systems. Two different drive versions are available, in which digital input 1 is assigned a different functionality.

  • Relay module design
    • SIDOOR ATD400W RELAY LB for connection of a light barrier
    • SIDOOR ATD400W RELAY RC for connection of a gate interlock
  • For dynamic door weights up to 400 kg
  • Automatic door weight detection
  • Operating temperature -20 to +50 °C
  • Flexible motor management (two different motor types), automatic detection
  • Opening width 0.3 to 4 m
  • Emergency power input via special emergency power module 24 V DC ± 15 %
  • Auxiliary power output 24 V DC ± 15 %; 0.4 A (short-circuit-proof)
  • Output stage short-circuit-proof
  • Vandal-proof
  • IP54 degree of protection for 180 to 400 kg motor versions, gear unit IP40
  • The "cord-operated switch" function is supported. Pulling the cord opens the door to an adjustable width
  • Pulse operation: The function remains active until a new command arrives
  • Hold-open time can be parameterized
  • A higher force can be set for the first 10 cm of the opening movement (boosting the door)

Дизайн



The SIDOOR ATD400K Cold Room Gate Drive consists of a number of components:

Version

Type

See

Controller

SIDOOR ATD400K cold room gate drives
(including terminal module and relay module)

  
  • SIDOOR ATD400K RELAY LB supports the light barrier function

6FB1141-1AT10-3KU2

 
  • SIDOOR ATD400W RELAY RC supports the gate interlock function

6FB1141-1AT11-3KU2

 

The following individual components must be ordered separately:

Power supplies

 

"Power supplies"

  • Mains transformer

6FB1112-0AT20-2TR0

 

Additional units
that enable universal implementation and maintenance of the door drive system

 

"Additional units"

  • Software Kit

6FB1105-0AT01-6SW0

 
  • Service Tool

6FB1105-0AT01-6ST0

 
  • Emergency power module

6FB1115-0AT10-4CP0

 

DC geared motors

 

"Geared motors"

  • SIDOOR M3 geared motors (max. door weight 180 kg, degree of protection IP40)
  
  • SIDOOR M3 L (pinion left)

6FB1103-0AT10-4MB0

 
  • SIDOOR M3 R (pinion right)

6FB1103-0AT11-4MB0

 
  • SIDOOR M4 geared motors (max. door weight 400 kg, degree of protection IP40)
  
  • SIDOOR M4 L (pinion left)

6FB1103-0AT10-3MC0

 
  • SIDOOR M4 R (pinion right)

6FB1103-0AT11-3MC0

 

Accessories for the complete system
see also overview diagram → "For elevators"

 

"Accessories"

  • Rubber-metal anti-vibration mounts
    for low-noise operation of the door drive system
  
  • for the SIDOOR M3 geared motor

6FB1104-0AT02-0AD0

 
  • for the SIDOOR M4 geared motor

6FB1104-0AT01-0AD0

 
  • Mounting bracket
  
  • for mounting the SIDOOR rubber-metal anti-vibration mount with a mounted geared motor

6FB1104-0AT01-0AS0

 
  • with tensioning device for mounting the deflector unit and setting the toothed belt to the required tension

6FB1104-0AT02-0AS0

 
  • Door clutch holder
    for attaching both ends of the toothed belt, and for connecting the respective door panel to the toothed belt
  
  • for toothed belt width of 12 mm

6FB1104-0AT01-0CP0

 
  • Deflector unit
    for deflecting the STS toothed belt in the same height and depth, aligned with motor drive pinion

6FB1104-0AT03-0AS0

 
  • Toothed belt STS, single-toothed,
    as a connection between the door system and the end positions of the door
  
  • Length 4 m, width 12 mm

6FB1104-0AT01-0AB0

 
  • Length 45 m, width 12 mm

6FB1104-0AT02-0AB0

 


Конфигурация



During initial commissioning, please note the following:

  • For mechanical installation and configuration, see the "SIDOOR Door Control Systems AT40, ATD400K, ATD400S, ATD400V, ATD400W" manual.http://support.automation.siemens.com/WW/view/en/58531074
  • Electrical configuration and commissioning:
    • Push the door into the "CLOSED" position.
    • Open the device cover.
    • Plug in the motor connector
    • Press and hold the learn run button
    • The learn run starts automatically and the learn run button can be released.
    • On completion of the learn run, the door is in the "CLOSED" position and the 7-segment display indicates "u".
    • The door can now be moved via the "OPEN" and "CLOSE" buttons with the default profile.

Особенности


  • 1-button operation for the entire commissioning process
  • Optimum and stable drive characteristics
  • Reduced service requirements and costs
  • SIDOOR User Software (part of the Software Kit, not included in the scope of delivery → see "Additional units") enables user-friendly operation and detailed diagnostics.
  • Integrated terminal module enables simple setup and diagnostics via an event and statistics memory.
  • Small footprint thanks to compact design
  • Automated functions for enhanced safety

Програмирование



The Software Kit is available as an additional unit (see "Additional units") and allows quick and easy updating of the firmware using the Siemens HCS12 Firmware Loader.

User-friendly parameter setting and oscilloscope function is carried out via the SIDOOR User Software (part of the Software Kit).

Технические данные



Order number

 

6FB1141-1AT10-3KU2

6FB1141-1AT11-3KU2

General technical data:

 

 

 

product brand name

 

SIDOOR

Product designation

 

Door controller

Product expansion optional

 

Mains transformer 6FB1112-0AT20-2TR0

Design of the product

 

ATD400K relay LS

ATD400K relay RC

Supply voltage:

 

 

 

Type of voltage supply

 

via SIDOOR mains transformer

Operating current of fuse protection at input when installing

 

6 ... 10

Consumed current maximum

A

10

I2t value minimum

A²·s

30

Active power consumption

 

 

 

  • Rated value

W

80

  • Rated value maximum

W

540

  • in standby mode Rated value

W

5

Inputs/ Outputs:

 

 

 

Input voltage per DC input

V

10 ... 28

Input current per DC input

mA

9 ... 27

Product property

 

 

 

  • Isolated control inputs

 

Yes

  • Control inputs switching to P potential

 

Yes

Output current at 24 V DC output maximum

mA

400

Property of the 24 V DC output

 

 

 

  • Note

 

CAUTION: Do not supply with external voltage!

  • Short-circuit proof

 

Yes

Switching capacity current of the output relay at DC at 50 V

 

0.01 ... 1

Switching capacity current of the output relay at AC at 230 V

 

0.01 ... 1

Door-relevant data:

 

 

 

Door opening width

m

0.3 ... 4

Weight of door maximum

kg

400

Operating cycle frequency of door maximum

1/h

180

Ambient conditions:

 

 

 

Ambient temperature during operation

°C

-20 ... +50

Ambient temperature during storage

°C

-40 ... +50

Relative humidity without condensation

 

10 ... 93

Protection class IP

 

IP20

Installation/ mounting/ dimensions:

 

 

 

Width

mm

320

Height

mm

60

Depth

mm

80

Standards:

 

 

 

Certificate of suitability CE marking

 

Yes

Standard for EMC

 

EN 61000-6-2 / EN 61000-6-3

Standard for safety

 

ISO 13849-1 PLd CAT2


Дальнейшая информация



For further product details, refer to the