SIDOOR ATD400T interior railway door drive Siemens
Область применения
The SIDOOR ATD400T interior railway door drive is an "intelligent" door drive which enables gangway doors to be opened and closed at adjustable speeds and accelerations.
The maintenance-free drive unit consists of a speed-controlled DC motor with non-self-locking gearing.
- SIDOOR M3 geared motor
(24 V DC/1.8 A; motor for max. overall door leaf weight 180 kg, degree of protection IP40)
Must be ordered separately, see "Geared motors".
Operation of the door drive does not require limit switches. The door width and the "OPEN" and "CLOSED" positions are determined automatically.
The current operating states are shown on a 7-segment display directly on the SIDOOR ATD400T RELAY controller. They can also be displayed externally using the Software Kit or Service Tool, see "Additional units".
Forces are transferred via a toothed belt, which passes over a deflector unit and can be fitted with two door clutch holders. The accessories are not included in the scope of supply, see "Accessories".
This enables it to drive both one-sided and centrally opening doors.
Обзор
SIDOOR ATD400T Interior Railway Door Drive
The SIDOOR ATD400T interior railway door drive is an "intelligent" door drive which enables gangway doors to be opened and closed at adjustable speeds and accelerations.
- Relay module design
- For dynamic door weights up to 180 kg
- Automatic door weight detection
- Operating temperature -20 to +70 °C 1)
- Flexible motor management (two different motor types), automatic detection
- Opening width 0.25 to 4 m
- Door can be operated with and without closing springs (60 to 80 N)
- With two identical door leaves, can be used up to a train inclination of 0 to 10%
- Forces and energies are limited in accordance with EN 14752
- EMC according to EN 50121-3-2
- Fulfills HL3 according to fire protection standard EN 45545-2 (Railway applications - Fire protection on rail vehicles)
- Vandal-proof
1) Note:
- Maximum output current at 24 V DC:
- 0.4 A at ≤ 55 °C ambient temperature during operation
- 0.1 A from 55 °C to 70 °C ambient temperature during operation, with restrictions at operating temperatures > 55 °C
- Maximum ambient temperature during operation:
- 55 °C
- 70 °C with restrictions at operating temperatures > 55 °C
- Restrictions at operating temperatures > 55 °C:
- Only use the 24 V output voltage to operate control inputs (max. 0.1 A)
- Use a sufficiently large (at least 350 x 350 mm), unpainted, metal mounting plate
- The maximum drive parameters are restricted to the default values
- If temperature class T3 according to EN 50155 is used, the maximum air temperature of 85 °C must not be exceeded near the printed-circuit board
Дизайн
The SIDOOR ATD400T RELAY drive system for interior railway doors consists of a number of components:
Version | Type | See |
---|---|---|
Controller | ||
SIDOOR ATD400T RELAY | 6FB1121-0BM13-3AT2 | |
The following individual components must be ordered separately: | ||
Additional units | "Additional units" | |
| 6FB1105-0AT01-6SW0 | |
| 6FB1105-0AT01-6ST0 | |
| 6FB1104-0AT20-0AT0 | |
DC geared motors | "Geared motors" | |
| ||
| 6FB1103-0AT10-4MB0 | |
| 6FB1103-0AT11-4MB0 | |
Accessories for the complete system | "Accessories" | |
| 6FB1104-0AT02-0AD0 | |
| ||
| 6FB1104-0AT01-0AS0 | |
| 6FB1104-0AT02-0AS0 | |
| 6FB1104-0AT02-0AS0 | |
| ||
| 6FB1104-0AT01-0CP0 | |
| 6FB1104-0AT03-0AS0 | |
| ||
|
|
Конфигурация
During initial commissioning, please note the following:
Mechanical installation and setting see "SIDOOR ATD400T controller for interior railway doors” Operating Instructions, http://support.automation.siemens.com/WW/view/en/82127712
- Electrical configuration and commissioning:
- Push the door into the "CLOSED" position.
- Open the enclosure cover
- Plug in the motor plug
- Connect DC power supply via line filter (SIDOOR EPM24)
- Press and hold the learn run button
- The learn run starts automatically and the learn run button can be released.
- On completion of the learn run, the door is in the "CLOSED" position and the terminal module indicates "u".
- The door can now be moved via the "OPEN" and "CLOSE" buttons (on the terminal module) with the default profile.
Особенности
- 1-button operation for the entire commissioning process
- Optimum and stable drive characteristics
- Reduced service requirements and costs
- SIDOOR User Software (part of the Software Kit, not included in the scope of delivery, see "Additional units") enables user-friendly operation and detailed diagnostics.
- Integrated terminal module enables simple setup and diagnostics via an event and statistics memory.
- Small footprint thanks to compact design
- Automated functions for enhanced safety
Технические данные
Order number |
| 6FB1121-0BM13-3AT2 | |
---|---|---|---|
General technical data: |
|
| |
product brand name |
| SIDOOR | |
Product designation |
| Door controller | |
Product expansion optional |
| EMC filter | |
Supply voltage: |
|
| |
Type of voltage supply |
| DC | |
Supply voltage at DC Rated value | V | 16.8 | |
Consumed current maximum | A | 15 | |
Active power consumption |
|
| |
| W | 80 | |
| W | 540 | |
Inputs/ Outputs: |
|
| |
Input voltage per DC input | V | 10 ... 28 | |
Input current per DC input | mA | 9 ... 27 | |
Product property |
|
| |
|
| Yes | |
|
| Yes | |
Output voltage at DC | V | 24 | |
Output current |
|
| |
| mA | 400 | |
| mA | 100 | |
Property of the 24 V DC output |
|
| |
|
| Yes | |
|
| Yes | |
|
| CAUTION: Do not supply with external voltage! | |
Switching capacity current of the output relay |
|
| |
| A | 0.01 ... 1 | |
| A | 0.01 ... 1 | |
Door-relevant data: |
|
| |
Door opening width | m | 0.25 ... 4 | |
Weight of door maximum | kg | 400 | |
Counterweight |
|
| |
| kg | 4 | |
| kg | 6 | |
| kg | 8 | |
Opposing force maximum | N | 80 | |
Operating cycle frequency of door maximum | 1/h | 180 | |
Ambient conditions: |
|
| |
Ambient temperature during operation |
| -25 ... +70 | |
|
| At operating temperatures > 55°C the operating parameters are limited to default values | |
|
| At operating temperatures > 55°C, the maximum air temperature of 85°C must not be exceeded near the printed-circuit board if temperature class T3 according to EN 50155 is used | |
Ambient temperature during storage |
| -40 ... +50 | |
Ambient temperature class acc. to EN 50155 |
| T3 | |
Relative humidity without condensation | % | 10 ... 93 | |
Protection class IP |
| IP20 | |
Installation/ mounting/ dimensions: |
|
| |
Width | mm | 320 | |
Height | mm | 60 | |
Depth | mm | 80 | |
Installation or assembly note |
| At operating temperatures > 55°C a sufficiently large (at least 350 x 350 mm), unpainted, metal mounting plate must be used | |
Standards: |
|
| |
Certificate of suitability CE marking |
| Yes | |
Standard for EMC |
| EN 50121-3-2 |
Дальнейшая информация
Further product details see
- System Manual “SIDOOR AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T”, http://support.automation.siemens.com/WW/view/en/58531074
- Operating Instructions (compact) “SIDOOR ATD400T controller for interior railway doors”, http://support.automation.siemens.com/WW/view/en/82127712