NT40 switch mode power supply Siemens

Обзор



The SIDOOR NT40 switch mode power supply unit is operated at 50/60 Hz, 230 V AC (± 15 %) to power the following SIDOOR door controllers:

  • SIDOOR AT40 and SIDOOR ATD400V Elevator Door Drives
  • SIDOOR ATD400W and SIDOOR ATD410W Machine Tool Door Drives
  • SIDOOR ATD400S Platform Screen Door Drive

It is especially suitable for door systems with high door weights.

On the output side, the power supply unit delivers a voltage of 36 V DC (± 3 %) SELV at a rated output power of < 100 W.

In order to enable fast acceleration/deceleration of the doors by the controller, the device can briefly (< 2 s) deliver a current of 15 A (corresponds to a short-time power output of 540 W).

Технические данные



Order number

 

6FB1112-0AT20-3PS0

General technical data:

 

 

Product designation

 

Switched-mode power supply

product brand name

 

SIDOOR

Design of the product

 

NT40

Electical data:

 

 

Supply voltage at AC

V

230

Supply voltage frequency at AC

Hz

47 ... 63

Relative symmetrical tolerance of the supply voltage

%

15

Input current at rated input voltage 230 V Rated value

A

0.7

Operating current of fuse protection at input when installing maximum

A

10

Consumed current for 2 s maximum

A

3.5

Apparent power consumption maximum

V·A

650

Active power supplied

 

 

  • maximum

W

100

  • limited to 2 s

W

540

Efficiency at 100 W active power output at 230 V AC

%

90

Operating resource protection class

 

I

Overvoltage category

 

2

Output voltage at DC Rated value

V

36

  • Note

 

SELV

Output current

A

0 ... 2.5

Active power consumption maximum Rated value

W

100

Short-term overload current for maximum 2 s

A

15

Tripping characteristic class of fuse protection at input when installing

 

B

Connections:

 

 

Type of electrical connection

 

 

  • at output

 

WAGO 721-103/026

  • at input

 

SCHUKO connector DIN 49.441, CEE7/VII

Cable length

 

 

  • Output side

m

1.5

  • line-side

m

2

Ambient conditions:

 

 

Ambient temperature during operation

 

-20 ... +55

  • Note

 

No direct exposure to the sun

Ambient temperature during storage

°C

-20 ... +70

Ambient temperature during transport

°C

-40 ... +70

Installation altitude at height above sea level maximum

m

2 000

Relative humidity without condensation

%

10 ... 93

Protection class IP

 

IP54

Installation/ mounting/ dimensions:

 

 

Mounting type

 

Four 5-mm screws

Width

mm

270

Height

mm

55

Depth

mm

80

Standards:

 

 

Standard for EMC

 

EMC Directive 2004/108/EC, EN 12015, EN 12016

Standard for safety

 

EN 60950-1:2006


Дальнейшая информация



For more product details see System Manual "SIDOOR AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ADT400T", http://support.automation.siemens.com/WW/view/en/58531074.