Article number code Siemens

Обзор
Structure of the article numbers for SIMOTICS FD motors
The Article No. consists of a combination of digits and letters and is divided into three hyphenated blocks to provide a better overview, e.g.:
1LM1212-3AB31-1AA0
The first block (positions 1 to 7) identifies the motor series, system description and the efficiency; the second block (positions 8 to 12) defines the motor frame size, the number of poles as well as the line voltage and frequency; and the third block (positions 13 to 16) encodes the speed, type of construction, terminal box, separately driven fan and heat exchanger position.
Ordering data:
- Complete Article No. and order code(s) or plain text
- If a quotation has been requested, please specify the quotation number in addition to the Article No.
- When ordering a complete motor as a spare part, please specify the works serial No. for the previously supplied motor as well as the Article No.
Note:
The structure of the Article No. of SIMOTICS FD motors supports the widest possible range of combinations. To check a configured Article No., the selection guide DT Configurator must be used.
The DT Configurator only permits technically implementable Article Nos. to be configured.
Structure of the Article No.: | Position: | 1 | 2 | 3 | 4 | 5 | 6 | 7 | - | 8 | 9 | 10 | 11 | 12 | - | 13 | 14 | 15 | 16 | ||||
SIMOTICS FD low-voltage motors | |||||||||||||||||||||||
Positions 1 to 4: Digit, letter, letter, digit | Motors without explosion protection | 1 | L |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Motors with explosion protection | 1 | M |
|
|
|
|
| ||||||||||||||||
Air-cooled, enclosed version with self-ventilation IC411 |
|
| M | 1 |
|
|
| ||||||||||||||||
Air-cooled, enclosed version with forced-air cooling, IC416 |
|
| Q | 1 |
|
|
| ||||||||||||||||
Water-cooled with water-jacket cooling, IC71W |
|
| H | 1 |
|
|
| ||||||||||||||||
Water-cooled with heat exchanger, IC86W |
|
| N | 1 |
|
|
| ||||||||||||||||
Motors exclusively without explosion protection | 1 | L |
|
|
|
|
| ||||||||||||||||
Air-cooled, open version with self-ventilation, IC01 |
|
| L | 1 |
|
|
| ||||||||||||||||
Air-cooled, open version with forced-air cooling, IC06 |
|
| P | 1 |
|
|
| ||||||||||||||||
Positions 5 to 7: | Frame size |
|
|
| |||||||||||||||||||
Low-noise standard version | 2 |
|
| ||||||||||||||||||||
Increased output version | 3 |
|
| ||||||||||||||||||||
Non-Siemens converter (standard) | 4 |
|
| ||||||||||||||||||||
Non-Siemens converter (increased output) | 5 |
|
| ||||||||||||||||||||
System description |
|
|
| ||||||||||||||||||||
Mains-fed operation (DOL) |
| 0 |
| ||||||||||||||||||||
Operation on SINAMICS converter with regulated infeed |
| 1 |
| ||||||||||||||||||||
Operation on SINAMICS converter with unregulated infeed |
| 2 |
| ||||||||||||||||||||
Operation on non-Siemens converter with regulated infeed |
| 3 |
| ||||||||||||||||||||
Operation on non-Siemens converter with unregulated infeed |
| 4 |
| ||||||||||||||||||||
Efficiency |
|
|
| ||||||||||||||||||||
High Efficiency |
|
| 2 | ||||||||||||||||||||
Premium Efficiency |
|
| 3 | ||||||||||||||||||||
Positions 8 and 9: Digit, letter | Frame sizes | 315 | 3 | A | |||||||||||||||||||
355 | 3 | B | |||||||||||||||||||||
400 | 4 | A | |||||||||||||||||||||
450 | 4 | B | |||||||||||||||||||||
Position 10: | N. of poles | 4‑pole | B | ||||||||||||||||||||
6‑pole | C | ||||||||||||||||||||||
8‑pole | D | ||||||||||||||||||||||
Position 11: | Laminated core length | 1 | |||||||||||||||||||||
Position 12: | Line voltage | 400 V, 50 Hz | 1 | ||||||||||||||||||||
500 V, 50 Hz | 2 | ||||||||||||||||||||||
690 V, 50 Hz – VSD | 3 | ||||||||||||||||||||||
690 V, 50 Hz – DOL | 4 | ||||||||||||||||||||||
460 V, 60 Hz | 5 | ||||||||||||||||||||||
575 V, 60 Hz | 6 | ||||||||||||||||||||||
Deviating data requires order code M.. (e. g. M1Y) | 9 | ||||||||||||||||||||||
Position 13: | Rated speed Encoded with 1 … 9; 9 requires order code N.. (e. g. N1Y) | 1 | |||||||||||||||||||||
Position 14: | Type of construction Encoded with A ... G, J … K | A | |||||||||||||||||||||
Position 15: Letter | Terminal box position Encoded with A … F one terminal box, K …P two terminal boxes | A | |||||||||||||||||||||
Position 16: | Separately driven fan – heat exchanger position 0: No separately driven fan/heat exchanger, 1 … 4: Separately driven fan position for air-cooled motors, 5: Heat exchanger, top | 0 | |||||||||||||||||||||
Special order versions: Encoded – additional order code required Not encoded – additional plain text required | - | Z |