Article number code Siemens

Обзор



Structure of the article numbers for SIMOTICS FD motors

The Article No. consists of a combination of digits and letters and is divided into three hyphenated blocks to provide a better overview, e.g.:
1LM1212-3AB31-1AA0

The first block (positions 1 to 7) identifies the motor series, system description and the efficiency; the second block (positions 8 to 12) defines the motor frame size, the number of poles as well as the line voltage and frequency; and the third block (positions 13 to 16) encodes the speed, type of construction, terminal box, separately driven fan and heat exchanger position.

Ordering data:

  • Complete Article No. and order code(s) or plain text
  • If a quotation has been requested, please specify the quotation number in addition to the Article No.
  • When ordering a complete motor as a spare part, please specify the works serial No. for the previously supplied motor as well as the Article No.

Note:

The structure of the Article No. of SIMOTICS FD motors supports the widest possible range of combinations. To check a configured Article No., the selection guide DT Configurator must be used.

The DT Configurator only permits technically implementable Article Nos. to be configured.

Structure of the Article No.:

Position:

1

2

3

4

5

6

7

-

8

9

10

11

12

-

13

14

15

16

  

SIMOTICS FD low-voltage motors

Positions 1 to 4: Digit, letter, letter, digit

Motors without explosion protection

1

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motors with explosion protection

1

M

 

 

 

 

 

Air-cooled, enclosed version with self-ventilation IC411

 

 

M

1

 

 

 

Air-cooled, enclosed version with forced-air cooling, IC416

 

 

Q

1

 

 

 

Water-cooled with water-jacket cooling, IC71W

 

 

H

1

 

 

 

Water-cooled with heat exchanger, IC86W

 

 

N

1

 

 

 

Motors exclusively without explosion protection

1

L

 

 

 

 

 

Air-cooled, open version with self-ventilation, IC01

 

 

L

1

 

 

 

Air-cooled, open version with forced-air cooling, IC06

 

 

P

1

 

 

 

Positions 5 to 7:
3 digits

Frame size

 

 

 

Low-noise standard version

2

 

 

Increased output version

3

 

 

Non-Siemens converter (standard)

4

 

 

Non-Siemens converter (increased output)

5

 

 

System description

 

 

 

Mains-fed operation (DOL)

 

0

 

Operation on SINAMICS converter with regulated infeed

 

1

 

Operation on SINAMICS converter with unregulated infeed

 

2

 

Operation on non-Siemens converter with regulated infeed

 

3

 

Operation on non-Siemens converter with unregulated infeed

 

4

 

Efficiency

 

 

 

High Efficiency

 

 

2

Premium Efficiency

 

 

3

Positions 8 and 9: Digit, letter

Frame sizes

315

3

A

355

3

B

400

4

A

450

4

B

Position 10:
Letter

N. of poles

4‑pole

B

6‑pole

C

8‑pole

D

Position 11:
Digit

Laminated core length

1

7

Position 12:
Digit

Line voltage

400 V, 50 Hz

1

500 V, 50 Hz

2

690 V, 50 Hz – VSD

3

690 V, 50 Hz – DOL

4

460 V, 60 Hz

5

575 V, 60 Hz

6

Deviating data requires order code M.. (e. g. M1Y)

9

Position 13:
Digit

Rated speed

Encoded with 1 … 9; 9 requires order code N.. (e. g. N1Y)

1
...
9

Position 14:
Letter

Type of construction

Encoded with A ... G, J … K

A
...
K

Position 15:

Letter

Terminal box position

Encoded with A … F one terminal box, K …P two terminal boxes

A
...
P

Position 16:
Digit

Separately driven fan – heat exchanger position

0: No separately driven fan/heat exchanger,

1 … 4: Separately driven fan position for air-cooled motors,

5: Heat exchanger, top

0
...
5

 

Special order versions:

Encoded – additional order code required

Not encoded – additional plain text required

-

Z