Braking Modules Siemens

Обзор



Braking Module

A Braking Module and the matching braking resistor are needed by the drive when it brakes or needs to be stopped for a specific reason, e.g. for an EMERGENCY STOP. Large fans which are caused to rotate by air flow are a typical application. In such instances, it is important to consider operating states which could result in speeds in excess of the desired maximum speed but also the possibility of reversal of rotational direction during restart from standstill. A braking unit is also required if the fan must be brought to a standstill within a defined time period.

The Braking Module houses the power electronics and the associated control circuit. The supply voltage for the electronics is taken from the DC link.

During operation, the DC link power is converted into heat loss in an external braking resistor.

The activation threshold of the Braking Module can be adjusted by means of a switch. The braking power values indicated in the technical specifications apply to the upper activation threshold.

Дизайн



The Braking Module is designed for installation in the control cabinet. It must always be mounted vertically.

A Braking Module is assigned its own dedicated braking resistor. The Braking Module is connected to the DC link by means of flexible cables.

The Braking Module has the following interfaces as standard:

  • DC link connection
  • Connection for braking resistor
  • 1 digital input (inhibit Braking Module/reset error)
  • 1 digital output (Braking Module faulty/ready)

A switch is provided for adjusting the activation threshold.

Характеристика



Load diagram for Braking Modules and braking resistor

Интеграция



Connection example of a Braking Module

Технические данные



Line voltage 380 ... 480 V 3 AC

Braking Module

 

6SL3760-1AE32-6AA0

Rated power PDB

50 kW

Power P20

200 kW

Braking current for PDB

65 A

Activation thresholds

(adjustable via switch)

670 V / 770 V (factory setting)

Connectable resistance

 

  • With braking power PDB

3.1 Ω

Digital input

 

  • Voltage

24 V

  • Low level
    (an open digital input is interpreted as "low")

<3 V

  • High level

<7 V

  • Current consumption at 24 V DC, typ.

0.01 mA

  • Conductor cross-section, max.

2.5 mm2

Digital output

 

  • AC voltage, max.

250 V

  • Load current per digital output, max.

2 A

  • Conductor cross-section, max.

2.5 mm2

Power loss, max.

0.1 kW

Braking resistor connection

Screw terminal

  • Conductor cross-section, max.

35 mm2

  • Cable length, max.

100 m

DC link connection

Screw terminal

  • Conductor cross-section, max.

35 mm2

  • Cable length, max.

3 m

Degree of protection

IP20

Dimensions

 

  • Width

180 mm

  • Height

220 mm

  • Depth

152 mm

Weight, approx.

5.5 kg