Разъединители с предохранителями Siemens

Обзор


 

Version

Order No.

40 mm center-to-center clearance, 12 x 5 or 2 x (12 x 5)

3NP40 15-1CK01

Fuse switch disconnectors, for NH000 fuse links

  • Rated current In: 160 A
  • Rated operational current Ie: 145 A
  • Connection 1.5 to 50 mm2
  • Fuses with max. 21 mm width, size 000 (according to IEC 269-2-1 and DIN 43620).
  • Connection over cable lugs, top

3NP4015-1CK01

8HP6 4..

Covers for 3NP4 01

 

Versions

 
  • Sealable

8HP6433

  • Not sealable

8HP6434

3NP40 75-1CE01

Fuse switch disconnectors, for NH00 fuse links

  • Rated current In: 160 A
  • Rated operational current Ie: 145 A
  • Connection up to 120 mm2
 

Versions

 
  • Connection over cable lugs, top (M8)

3NP4075-1CE01

  • Connection over cable lugs, bottom (M8)

3NP4075-1CF01

8HP6 4..

Covers for 3NP407

 

Versions

 
  • Single mounting
 
  • Sealable

8HP6425

  • Not sealable

8HP6435

  • Double mounting
 
  • Sealable

8HP6426

  • Not sealable

8HP6436

3NP42 75-1CG01

Fuse switch disconnectors, for NH1 fuse links

  • Rated current In: 250 A
  • Rated operational current Ie: 225 A
  • Connection up to 150 mm2
  • Connection over cable lug top (M10) and bottom (M10)

3NP4275-1CG01

Note

 
  • Raised cover or intermediate frame required see Distribution Systems –> Empty Enclosures.
  • When using Cu 12 × 5 mm, a 3NY7 381 bar thickness compensation must be used (1 set = 5 components).
  • If mounting on 5-mm busbars, an additional 3NY7 381 busbar thickness compensator is required.
 

8HP6 4..

Covers for 3NP4 2

 

Versions

 
  • Sealable

8HP6427

  • Not sealable

8HP6437

49 mm center-to-center clearance, 20 x 8 or 2 x (20 x 8)

 

Fuse switch disconnectors, for NH00 / 2x NH00 / NH1 fuse links from A. Jung, Ostrach

  • All isolators incl. cover
 

Versions

Rated current In

Rated operational current Ie

Connection

 
  • NH00

160 A

145 A

Up to 50 mm² terminal clamp, top or bottom

8HP4310

  • 2x NH00

160 A

145 A

Up to 50 mm² terminal clamp, top or bottom

8HP4311

  • NH1

250 A

225 A

Up to 120 mm² cable connection, top or bottom

8HP4314

Note

    

Raised cover or intermediate frame required see Distribution Systems –> Empty Enclosures.

 


Дизайн



Mounting instructions

  • For installation dimensions see ALPHA 8HP molded-plastic distribution systems -> Dimensional drawings.
  • 40 mm center-to-center clearance suitable for 8HP1 701, 8HP1 790 and 8HP1 791.
  • 49 mm center-to-center clearance for 8HP1 704.

Дополнительно



Accessories

   
 

Description

Version

Article No.

3NP1920-1FA00

Auxiliary switch (changeover contact)

000

3NP1920-1FA00

00

3NP1930-1FA00

3NP1900-1HA00

Locking devices

  • 1 set = 10 units

000, 00

3NP1900-1HA00

3NP1933-1BA00

Saddle terminals, single 1.5 ... 70 mm²

  • 1 set = 3 units
  • For flat terminals

00

3NP1933-1BA00

3NP1923-1BD00

Feeder terminals, 16 ... 95 mm²

  • 1 set = 3 units
  • For box terminals
  • To increase the size of the conductor cross-section

000

3NP1923-1BD00

3NP1933-1GB20

Handle unit with electronic fuse monitoring EFM10
for flat terminals

  • Installation of the handle unit is only possible with higher covers or intermediate frames see Empty enclosures.

000

3NP1923-1GB20

00

3NP1933-1GB20