1PH8 for SINAMICS S120 Combi for machine tools Siemens

Область применения
- Main spindles for standard milling and turning machines
- Driven tools for standard turning machines
Обзор
SIMOTICS M-1PH808 spindle motor with forced ventilation
SIMOTICS M-1PH8 motors are compact squirrel-cage asynchronous motors with degree of protection IP55. SIMOTICS M-1PH8 motors have been designed specifically for use in conjunction with the SINAMICS S120 drive system. Depending on the control requirements, appropriate encoder systems are available for the motors for sensing the motor speed and indirect position.
The SIMOTICS M-1PH8 spindle motors are perfectly adapted to the SINAMICS S120 Combi drive system.
Функции
- Compact asynchronous spindle motors
- Spindle power: 2.8 to 12 kW
- Shaft heights: 80 to 132
- Maximum speed: 24000 rpm
- Electronic rating plate in motor encoder
- Integrated, easily replaceable fan
- Integrated terminal box for power cable
- DRIVE-CLiQ interface for signal cable
- IP55 degree of protection (including fan)
- Vibration severity grade S/A and Special/B
- High rotational accuracy
- Optimized bearing design for high cantilever forces
Особенности
- Maximum power over an extremely wide speed range as a result of intelligent winding design and optimized field weakening and heat dissipation concept
- Very fast spindle acceleration rates and maximum cutting forces thanks to special lamination structure and high overload factor
- Long-lasting motor bearings for high radial forces with belt drives
- High degree of protection, including motor fan
Опции
Order code | Description |
---|---|
K23 | Special paint finish for "Worldwide" climate group: |
When ordering a motor with options, -Z should be added to the article number.
Технические данные
Product designation | SIMOTICS M-1PH8 motor |
Cooling | Forced ventilation |
Ambient temperature, admissible | -15 ... +40 °C (5 ... 104 °F) |
Temperature monitoring | KTY84 temperature sensor in stator winding |
Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) | For an ambient temperature of up to 40 °C (104 °F) |
| Temperature class 180 (H) |
Motor fan ratings | |
| 230 V 1 AC ± 10 %, 50 Hz |
| 400 V 3 AC ± 10 %, 50 Hz |
Encoder system, built-in | DRIVE-CLiQ interface |
| 22 bit incremental encoder (resolution 4194304, internal 2048 S/R) + commutation position 11 bit (IC22DQ encoder) |
| 20 bit incremental encoder (resolution 1048576, internal 512 S/R) |
| 19 bit incremental encoder (resolution 524288, internal 256 S/R) |
Sound pressure level LpA (1 m) | Rated pulse frequency 4 kHz and speed range up to 5000 rpm |
| 70 dB |
Connection | |
| Terminal box top/cable entry from right/signal connection DE |
| |
| Power connector |
| Terminals in terminal box |
| Connector for signals (without mating connector) or DRIVE-CLiQ |
Vibration severity | In accordance with Siemens/EN 60034-14 (IEC 60034-14) |
Shaft and flange accuracy1) | In accordance with Siemens/DIN 42955 (IEC 60072-1) |
Degree of protection in accordance with | |
| IP55 |
| IP55 |
Rating plate | 1 unit attached to motor |
Paint finish | Anthracite RAL 7016 |
Certificate of suitability | cURus |
1) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.
Terminal box assignment, max. connectable conductor cross-sections
1PH8 motor | Terminal box | Cable entry | Outer cable diameter, max.2) | Number of main terminals | Cross-section per terminal, max. | Rated current, max.3) | ||
---|---|---|---|---|---|---|---|---|
Type | Type | Power | External signals | |||||
mm (in) | mm2 | A | ||||||
1PH808 | gk803 | 1 × M25 × 1.5 | 1 × Ø 22 mm4) | 20 (0.79) | Phases: 3 × M5 | 1 × 10 | 50 | |
1PH810 | gk813 | 1 × M32 × 1.5 | 1 × Ø 22 mm4) | 24.2 (0.95) | Phases: 3 × M5 | 1 × 16 | 66 | |
1PH810 | star/delta | gk826 | 1 × M32 × 1.5 | 1 × Ø 22 mm4) | 24.2 (0.95) | Phases: 6 × M5 | 1 × 10 | 50 |
1PH813 | gk833 | 1 × M40 × 1.5 | 1 × Ø 22 mm4) | 32 (1.26) | Phases: 3 × M6 | 1 × 35 | 104 |
2) Dependent on the design of the metric cable gland.
3) Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52, according to installation type C.
4) Hole with diameter 22 mm (0.87 in), 90° to signal connection.