Signal cables Siemens

Область применения



DRIVE‑CLiQ signal cables

DRIVE-CLiQ signal cables are used to connect components with DRIVE-CLiQ connections which have a separate or external 24 V DC power supply.

MOTION‑CONNECT DRIVE‑CLiQ signal cables

MOTION‑CONNECT DRIVE‑CLiQ signal cables with 24 V DC cores are used whenever components with DRIVE-CLiQ connections must meet high requirements such as mechanical stress and oil resistance, e.g. where a connection is made outside the cabinet between Power Modules/Motor Modules and SIMOTICS S-1FK7/SIMOTICS M-1PH8 motors with DRIVE-CLiQ interface.

MOTION-CONNECT pre-assembled signal cables

MOTION-CONNECT pre-assembled signal cables are used whenever motor encoders on motors without DRIVE-CLiQ interface are connected to Sensor Modules.

Обзор



MOTION‑CONNECT DRIVE‑CLiQ signal cable with IP20/IP67 connector

Signal cables are pre-assembled and are sold by the meter for the connection of a variety of components.

The following different types of cable are available:

  • DRIVE‑CLiQ signal cables
  • MOTION‑CONNECT DRIVE‑CLiQ signal cables
  • MOTION‑CONNECT pre-assembled signal cables

Конфигурация



Pre-assembled DRIVE-CLiQ signal cables without 24 V DC cores

Type

Length

Dmax

Degree of protection
Connector

DRIVE-CLiQ signal cable
without 24 V DC cores

 

m (ft)

mm (in)

 

Article No.

Fixed lengths

0.11 (0.36)

 

IP20/IP20

6SL3060‑4AB00‑0AA0

0.16 (0.52)

6SL3060‑4AD00‑0AA0

0.21 (0.69)

6SL3060‑4AF00‑0AA0

0.26 (0.85)

6SL3060‑4AH00‑0AA0

0.31 (1.02)

6SL3060‑4AK00‑0AA0

0.36 (1.18)

6SL3060‑4AM00‑0AA0

0.41 (1.35)

6SL3060‑4AP00‑0AA0

0.60 (1.97)

6SL3060‑4AU00‑0AA0

0.95 (3.12)

6SL3060‑4AA10‑0AA0

1.20 (3.94)

6SL3060‑4AW00‑0AA0

1.45 (4.76)

6SL3060‑4AF10‑0AA0

2.80 (9.19)

6SL3060‑4AJ20‑0AA0

5.00 (16.4)

6SL3060‑4AA50‑0AA0

To the decimeter

max. 70 (230)

7.0

IP20/IP20

6FX2002‑1DC00‑....

Length code

....



Pre-assembled MOTION-CONNECT DRIVE-CLiQ signal cables with 24 V DC cores

Type

Usage

Length, max.

Dmax

Degree of protection
Connector

MOTION-CONNECT
DRIVE-CLiQ signal cable
with 24 V DC cores

  

m (ft)

mm (in)

 

Article No.

To the decimeter

For built-in or built-on encoder systems with DRIVE-CLiQ.

For example, for making the connection between SIMOTICS motors and SINAMICS S120 Motor Modules or Power Modules.

75 (246)

7.1 (0.28)

IP20/IP67

6FX8002‑2DC10‑....

100 (328)

7.1 (0.28)

IP20/IP67

6FX5002‑2DC10‑....

MOTION‑CONNECT 500

      5

MOTION‑CONNECT 800PLUS

      8

Length code

....



Pre-assembled signal cables for direct or external measuring systems with full-thread connector

Encoder system

Connection via

Length, max.

Dmax 

Degree of protection
Connector1)

Basic cable

Extension

 

 

m (ft)

mm (in)

 

Article No.

Article No.

Absolute encoder with EnDat

SMC20

100 (328)

9.8 (0.39)

IP20/IP67

6FX❑002‑2EQ10‑....

6FX❑002‑2EQ14‑....

Absolute encoder with EnDat
6FX2001-5.E..

SMC20

100 (328)

9.2 (0.36)

IP20/IP67

6FX❑002‑2CH00‑....

6FX❑002‑2AD04‑....

Absolute encoder with SSI
6FX2001-5.S..
24 V DC
Clock-pulse rate 100 ... 250 kHz

SMC30

100 (328)

9.3 (0.37)

IP20/IP67

6FX❑002‑2CC11‑....

6FX❑002‑2CB54‑....

Incremental encoder sin/cos 1 Vpp
2048 S/R, with C and D tracks

SMC20

100 (328)

9.8 (0.39)

IP20/IP67

6FX❑002‑2CA31‑....

6FX❑002‑2CA34‑....

Incremental encoder sin/cos 1 Vpp
256 and 512 S/R, without C and D tracks

SMC20

50 (164)

9.2 (0.36)

IP20/IP67

6FX8002‑2CA80‑....

6FX❑002‑2CA34‑....

HTL incremental encoder

SMC30

3002)

9.3 (0.37)

IP20/IP67

6FX❑002‑2AH00‑....

6FX❑002‑2AH04‑....

Incremental encoder sin/cos 1 Vpp without C and D tracks
6FX2001-3

SMC20

50 (164)

9.3 (0.37)

IP20/IP67

6FX❑002‑2CG00‑....

6FX❑002‑2CB54‑....

HTL incremental encoder
24 V DC
6FX2001‑4

SMC30

100 (328)

9.3 (0.37)

–/IP67

6FX5002‑2CA12‑....

TTL incremental encoder RS422
6FX2001‑2

      
  • 5 V DC

SMC30

100 (328)

9.3 (0.37)

IP20/IP67

6FX❑002‑2CR00‑....

6FX❑002‑2CB54‑....

  • 24 V DC

SMC30

100 (328)

9.3 (0.37)

IP20/IP67

6FX❑002‑2CD24‑....

6FX❑002‑2CB54‑....

MOTION‑CONNECT 500

      5

      5

MOTION‑CONNECT 800PLUS

      8

      8

Length code

....

....



1) The specification of the degree of protection refers to the basic cable.

2) Applicable to HTL encoders with bipolar signal evaluation or for evaluation of the difference signals A*, A and B*, B; for HTL encoders with unipolar signal evaluation, the permissible cable length is reduced to 100 m.

The combinations of signal cable extensions shown are only provided by way of example.

The maximum specified cable length (basic cable and extensions) must not be exceeded. The total maximum length is reduced by 2 m (6.56 ft) for each interruption point.

Технические данные



DRIVE‑CLiQ signal cables

DRIVE‑CLiQ

DRIVE‑CLiQ MOTION‑CONNECT 500

DRIVE‑CLiQ MOTION‑CONNECT 800PLUS

 

6FX2...‑1DC..‑....

6FX5...‑.DC..‑....

6FX8...‑.DC..‑....

Approvals, according to

   
  • cURus or UR/CSA

UL STYLE 2502/CSA-N.210.2-M90

UL STYLE 2502/CSA-N.210.2-M90

UL STYLE 20236/CSA-N.210.2-M90

  • UR-CSA File No.1)

Yes

Yes

Yes

  • RoHS conformity

Yes

Yes

Yes

Rated voltage according to EN 50395

30 V

30 V

30 V

Test voltage, rms

500 V

500 V

500 V

Operating temperature on the surface

   
  • Fixed installation

‑20 … +80 °C (‑4 ... +176 °F)

‑20 … +80 °C (‑4 ... +176 °F)

‑20 … +80 °C (‑58 ... +176 °F)

  • Flexible installation

0 … 60 °C (+32 ... +140 °F)

‑20 … +60 °C (‑4 ... +140 °F)

Tensile stress, max.

   
  • Fixed installation

45 N/mm2 (6526 lbf/in2)

80 N/mm2 (11603 lbf/in2)

50 N/mm2 (7252 lbf/in2)

  • Flexible installation

30 N/mm2 (4351 lbf/in2)

20 N/mm2 (2901 lbf/in2)

Smallest bending radius

   
  • Fixed installation

50 mm (1.97 in)

35 mm (1.38 in)

35 mm (1.38 in)

  • Flexible installation

125 mm (4.92 in)

75 mm (2.95 in)

Torsional stress

Absolute 30°/m

Absolute 30°/m

Bending

100000

10 million

Traversing velocity

30 m/min (98.4 ft/min)

300 m/min (984 ft/min)

Acceleration

2 m/s2 (6.56 ft/s2)

Up to 50 m/s2 (164 ft/s2)
see charasteristic curves under "MOTION‑CONNECT connection systems"

Insulation material,
incl. jacket

CFC/silicone-free

CFC/silicone-free

CFC/halogen/silicone-free
IEC 60754‑1/DIN VDE 0472‑815

Oil resistance

EN 60811‑2‑1

EN 60811‑2‑1
(mineral oil only)

EN 60811‑2‑1

Outer jacket

PVC

PVC

PUR, HD22.10 S2 (VDE 0282, Part 10)

 

Gray RAL 7032

DESINA color green RAL 6018

DESINA color green RAL 6018

Flame-retardant

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3



1) The File No. is printed on the cable jacket.

Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.

Signal cables

MOTION‑CONNECT 500

MOTION‑CONNECT 800PLUS

 

6FX500.‑....‑....

6FX800.‑.....‑....

Approvals, according to

  
  • cURus or UR/CSA

UL758-CSA-C22.2-N.210.2-M90

UL758-CSA-C22.2-N.210.2-M90

  • UR-CSA File No.1)

Yes

Yes

  • RoHS conformity

Yes

Yes

Rated voltage according to EN 50395

30 V

30 V

Test voltage, rms

500 V

500 V

Operating temperature on the surface

  
  • Fixed installation

-20 … +80 °C (‑4 ... +176 °F)

-50 … +80 °C (‑58 ... +176 °F)

  • Flexible installation

0 … 60 °C (+32 ... +140 °F)

-20 … +60 °C (‑4 ... +140 °F)

Tensile stress, max.

  
  • Fixed installation

50 N/mm2 (7252 lbf/in2)

50 N/mm2 (7252 lbf/in2)

  • Flexible installation

20 N/mm2 (2901 lbf/in2)

20 N/mm2 (2901 lbf/in2)

Smallest bending radius

  
  • Fixed installation

60 mm (2.36 in)

4 x Dmax

  • Flexible installation

100 mm (3.94 in)

70 mm (2.76 in)

Torsional stress

Absolute 30°/m

Absolute 30°/m

Bending

2 million

10 million

Traversing velocity

180 m/min (591 ft/min)

Up to 300 m/min (984 ft/min)

Acceleration

5 m/s2 (16.41 ft/s2)

Up to 50 m/s2 (164 ft/s2)
see charasteristic curves under "MOTION‑CONNECT connection systems"

Insulation material, incl. jacket

CFC/silicone-free

CFC/halogen/silicone-free
IEC 60754‑1/DIN VDE 0472‑815

Oil resistance

EN 60811‑2‑1 (mineral oil only)

EN 60811‑2‑1

Outer jacket

PVC

PUR, HD22.10 S2 (VDE 0282, Part 10)

 

DESINA color green RAL 6018

DESINA color green RAL 6018

Flame-retardant

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3



1) The File No. is printed on the cable jacket.

Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.