Industrial USB Hub 4 Siemens
Область применения
The Industrial USB Hub 4 enables up to 4 I/O devices, such as USB FlashDrive, USB card reader, etc., to be connected simultaneously to the operator components. The cabinet door no longer has to be opened in order to connect the I/O devices, which increases the availability of the system operated. Continuous operation of the operator component is therefore possible.
Обзор
The Industrial USB Hub 4 is used to connect I/O devices to SINUMERIK PCU 50.5 Windows 7. USB peripherals can be connected to the operator component and operated via the Industrial USB Hub 4 without opening the cabinet door.
The Industrial USB Hub 4 differs from commercially available USB hubs mainly in its suitability for use in rugged industrial environments (IP65).
Интеграция
The Industrial USB Hub 4 is suitable for connection to:
- SINUMERIK PCU 50.5 Windows 7
Der Industrial USB hub 4 is released for the Windows CE/2000/XP/Windows 7 operating systems. The appropriate drivers are supplied with the operating system software.
Compared with conventional USB hubs, the Industrial USB Hub 4 is also suitable for use in a severe industrial environment on account of its degree of protection IP65.
Особенности
- Inspection window for each interface
- Vibration-proof latching of connected USB cables and USB flash drive
- One LED per interface for checking the data traffic
- Sufficient interior space for easy insertion and removal of USB plugs and USB FlashDrives
- Can be installed in a control cabinet or on a standard rail
Технические данные
Order number | 6AV6671-3AH00-0AX0 | |
---|---|---|
Product type designation | Industrial USB Hub 4 | |
Supply voltage |
| |
| 24 V | |
| 20.4 ... 28.8 V | |
Number of interfaces acc. to USB | 4 | |
| Type USB 2.0, 500 mA each; e.g. connection of mouse, keyboard, printer, USB stick, USB IPC flash drive | |
Mounting type rail mounting | Yes | |
| Standard - DIN rail | |
Protection class IP |
| |
| IP65 | |
| IP20 | |
Relative humidity during operation maximum | 90 % | |
Ambient temperature during storage and transport | -20 ... +60 °C (-4 ... +140 °F) | |
Operating temperature in landscape format in vertical mounting position | 0 ... 50 °C (32 ... 122 °F) | |
Width of the enclosure front | 212 mm (8.34646 in) | |
Height of the enclosure front | 156 mm (6.14173 in) | |
Installation depth | 50 mm (1.9685 in) | |
Weight | 460 g (16.22602 oz) | |
Certificate of suitability |
| |
| Yes | |
| UL for US, UL for Canada | |
| C-Tick |