Active Line Modules in booksize format Siemens
![](https://pzip.ru/Images/Siemens/cat/P_NC01_XX_01063i.jpg)
Обзор
Active Line Modules are self-commutated feed/feedback units (with IGBTs in infeed and regenerative feedback directions) and generate a regulated DC link voltage. This means that the connected Motor Modules are decoupled from the line voltage. Line voltage fluctuations within the permissible supply tolerances have no effect on the motor voltage. Active Line Modules are designed for connection to grounded, star (TN, TT) and non-grounded, symmetrical IT systems.
The DC link is pre-charged via integrated pre-charging resistors.
In order to operate an Active Line Module, it is absolutely essential to use the appropriate Active Interface Module.
Дизайн
The Active Line Modules in booksize format feature the following connections and interfaces as standard:
- 1 power connection via screw-type terminals
- 1 connection for the 24 V DC electronics power supply via the 24 V terminal adapter included in the scope of supply
- 1 DC link connection via integrated DC link busbars
- 3 DRIVE‑CLiQ sockets
- 2 PE (protective earth) connections
The status of the Active Line Modules is indicated via two multi-color LEDs.
On the 100 mm (3.94 in) wide Active Line Module, the shield for the power supply cable can be connected to the integrated shield connection plate via a shield connection terminal or tube clip, e.g. Weidmüller type KLBÜ CO 4. The shield connection terminal must not be used for strain relief. Shield connection plates are available for the 150 mm (5.91 in), 200 mm (7.87 in) and 300 mm (11.81 in) wide modules.
The signal cable shield can be connected to the Line Module by means of a shield connection terminal, e.g. Weidmüller type KLBÜ 3‑8 SC.
The scope of supply of the Active Line Modules includes:
- DRIVE‑CLiQ cable for connection to the adjacent Control Unit on the left for drive control, length 0.11 m (4.33 in)
- DRIVE‑CLiQ cable (length depends on module width) to connect Active Line Module to adjacent Motor Module, length = width of Active Line Module + 0.11 m (4.33 in)
- 2 blanking plugs for sealing unused DRIVE-CLiQ sockets
- Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
- 24 V terminal adapter (X24)
- Connector X21 for digital inputs
- Fan insert for Active Line Modules of 80 kW (107 HP) and 120 kW (161 HP) (the voltage is supplied by the Active Line Module)
- 1 set of warning signs in 30 languages
- 1 heat conducting foil
(for Active Line Modules with cold plate cooling only)
Характеристика
Overload capability
Load cycle with previous load
S6 load cycle with previous load
S6 load cycle with previous load
55 kW (73.8 HP) Active Line Module only:
Peak power load duty cycle with previous load
Derating characteristics
Output power dependent on ambient temperature
Output power dependent on installation altitude
Voltage derating dependent on installation altitude
Интеграция
The Active Line Module receives its control information via DRIVE‑CLiQ from:
- CU320‑2 Control Unit
- SINUMERIK 840D sl with
- NCU 710.3B PN
- NCU 720.3 PN
- NCU 730.3 PN
- Numeric Control Extensions NX10.3/NX15.3
- SIMOTION D
Connection example of Active Line Module in booksize format
Технические данные
Active Line Module in booksize format 6SL313... |
|
---|---|
Line voltage (up to 2000 m (6562 ft) above sea level) | 380 ... 480 V 3 AC ±10 % (in operation -15 % <1 min) |
Line frequency | 47 ... 63 Hz |
SCCR (short-circuit current rating) | 65 kA in conjunction with the recommended fuses class J or circuit breakers in accordance with UL489 / CSA 22.2 No. 5-02 see recommended line-side components |
Line power factor |
|
|
|
| 1 (factory setting), can be altered by input of a reactive current setpoint |
| 1 (factory setting) |
|
|
| >0.96 |
| 0.65 ... 0.9 |
Overvoltage category to EN 60664‑1 | Class III |
DC link voltage Vd | In Active Mode, the DC link voltage is regulated and can be adjusted as a voltage decoupled from the line voltage. In Smart Mode, the DC link voltage is kept in proportion to the line voltage at the mean rectified line voltage value. Factory setting for DC link voltage: 380 ... 400 V 3 AC: 600 V (Active Mode) 400 ... 415 V 3 AC: 625 V (Active Mode) 416 ... 480 V 3 AC: 1.35 × line voltage (Smart Mode) 1) |
Electronics power supply | 24 V DC, -15 %/+20 % |
Radio interference suppression |
|
| Category C3 to EN 61800‑3 up to 350 m (1148 ft) total cable length |
| Category C2 according to EN 61800-3 up to 350 m (1148 ft) total cable length |
Type of cooling | Internal air cooling (power units with increased air cooling by built-in fan) External air cooling (power units with increased air cooling by built-in fan) Cold plate cooling Liquid cooling |
Permissible ambient and coolant temperature (air) during operation for line-side components, Line Modules and Motor Modules | 0 ... 40 °C (32 ... 104 °F) without derating, |
Installation altitude | Up to 1000 m (3281 ft) above sea level without derating, |
Declarations of conformity | CE (Low-Voltage and EMC Directives) |
Approvals, according to | cULus |
1) Active Mode can also be selected if the connected motors are suitable for > 650 V DC.
Line voltage 380 ... 480 V 3 AC | Active Line Module in booksize format | |||||
---|---|---|---|---|---|---|
Internal air cooling | 6SL3130-... | 7TE21-6AA4 | 7TE23-6AA3 | 7TE25-5AA3 | 7TE28-0AA3 | 7TE31-2AA3 |
External air cooling | 6SL3131-... | 7TE21-6AA3 | 7TE23-6AA3 | 7TE25-5AA3 | 7TE28-0AA3 | 7TE31-2AA3 |
Cold plate cooling | 6SL3136-... | 7TE21-6AA3 | 7TE23-6AA3 | 7TE25-5AA3 | 7TE28-0AA3 | 7TE31-2AA3 |
Liquid cooling | 6SL3135-... | – | – | – | – | 7TE31-2AA3 |
Infeed/regenerative feedback power |
|
|
|
|
|
|
| ||||||
| kW | 16 | 36 | 55 | 80 (64 1)) | 120 (84 1)) |
| (HP) | (18) | (40) | (60) | (100) (75 1)) | (150) (100 1)) |
| kW | 21 | 47 | 71 | 106 (85 1)) | 145 (116 1)) |
| kW | 35 | 70 | 91 (110 2)) | 131 | 175 |
DC link current |
|
|
|
|
|
|
| A | 27 | 60 | 92 | 134 | 200 |
| A | 35 | 79 | 121 | 176 | 244 |
| A | 59 | 117 | 152 (176 2)) | 218 | 292 |
Input current |
|
|
|
|
|
|
| A | 26/25/21 | 58/55/46 | 88/84/70 | 128/122/102 | 192/182/152 |
| A | 32 | 71 | 108 | 161 | 220 |
| A | 54 | 107 | 139 (168 2)) | 200 | 267 |
Power requirement 24 V DC electronics power supply, max. | A | 1.1 | 1.5 | 1.9 | 2 | 2.5 (2.1 3)) |
Current carrying capacity |
|
|
|
|
|
|
| A | 20 | 20 | 20 | 20 | 20 |
| A | 100 | 200 | 200 | 200 | 200 |
DC link capacitance |
|
|
|
|
|
|
| μF | 710 | 1410 | 1880 | 2820 | 3995 |
| μF | 20000 | 20000 | 20000 | 20000 | 20000 |
Internal/external air cooling |
|
|
|
|
|
|
|
|
|
|
|
|
|
| kW | 0.29 | 0.67 | 0.95 | 1.39 | 2.26 |
| kW | 0.09/0.2 | 0.17/0.5 | 0.25/0.7 | 0.3/1 | 0.55/1.71 |
| m3/s (ft3/s) | 0.016 (0.565) | 0.031 (1.095) | 0.044 (1.554) | 0.144 (5.085) | 0.144 (5.085) |
| dB | <60 | <65 | <60 | <75 | <75 |
Cold plate cooling |
|
|
|
|
|
|
| kW | 0.07/0.21 | 0.13/0.52 | 0.19/0.74 | 0.3/1.1 | 0.46/1.8 |
| K/W | 0.075 | 0.055 | 0.05 | 0.028 | 0.028 |
Liquid cooling 5) |
|
|
|
|
|
|
| kW | – | – | – | – | 0.46/1.8 |
| l/min | – | – | – | – | 8 |
| ml | – | – | – | – | 100 |
| °C (°F) | – | – | – | – | 45/50 (113/122) |
| dB | – | – | – | – | <73 |
Line connection U1, V1, W1 |
| Screw-type terminals (X1) | M6 screw studs (X1) | M8 screw studs (X1) | M8 screw studs (X1) | M8 screw studs (X1) |
| mm2 | 2.5 ... 10 | 2.5 ... 50 | 2.5 ... 95, 2 × 35 | 2.5 ... 120, 2 × 50 | 2.5 ... 120, 2 × 50 |
Shield connection |
| Integrated in the connector | See Accessories | See Accessories | See Accessories | See Accessories |
PE connection |
| M5 screw | M6 screw | M6 screw | M8 screw | M8 screw |
Cable length, max. Total of all motor cables and DC link |
|
|
|
|
|
|
| m (ft) | 630 (2067)7) | 630 (2067)7) | 1000 (3281) | 1000 (3281) | 1000 (3281) |
Degree of protection |
| IP20 | IP20 | IP20 | IP20 | IP20 |
Dimensions |
|
|
|
|
|
|
| mm (in) | 100 (3.94) | 150 (5.91) | 200 (7.87) | 300 (11.81) | 300 (11.81) |
| mm (in) | 380 (14.96) | 380 (14.96) | 380 (14.96) | 380 (14.96) | 380 (14.96) |
| mm (in) | – | – | – | 629 (24.76) | 629 (24.76) |
| mm (in) | – | – | – | 629 (24.76) | 553 (21.77)6) |
|
|
|
|
|
|
|
| mm (in) | 270 (10.63) | 270 (10.63) | 270 (10.63) | 270 (10.63) | 270 (10.63) |
| mm (in) | 226/66.5 (8.90/2.62) | 226/71 (8.90/2.80) | 226/92 (8.90/3.62) | 226/82 (8.90/3.23) | 226/82 (8.90/3.23) |
| mm (in) | 226 (8.90) | 226 (8.90) | 226 (8.90) | 226 (8.90) | 226 (8.90) |
| mm (in) | – | – | – | – | 226 (8.90) |
Weight, approx. |
|
|
|
|
|
|
| kg (lb) | 7 (15.4) | 10.3 (22.7) | 17 (37.5) | 23 (50.7) | 23 (50.7) |
| kg (lb) | 8.8 (19.4) | 13.8 (30.4) | 18.5 (40.8) | 27.7 (61.1) | 30.7 (67.7) |
| kg (lb) | 6.1 (13.5) | 10.2 (22.5) | 13.8 (30.4) | 20.3 (44.8) | 20.4 (45.0) |
| kg (lb) | – | – | – | – | 23 (50.7) |
1) In the case of cold-plate cooling, derating is necessary due to heat transfer to the external heat sink.For further information, see chapter System description - Dimensioning.
2) Higher peak power is possible in combination with the Active Interface Module 6SL3100-0BE25-5AB0 (for operating cycle constraints, see SINAMICS S120 Manual).
3) For 6SL3135-7TE31-2AA3.
4) Power loss of Active Line Module at rated power including losses of 24 V DC electronics power supply.
5) The coolant connections are located on the lower side of the components. All connection elements can be accessed using an appropriate tool. Thread type of water connections: Pipe thread ISO 228 G ½ B.
6) This value applies to water as coolant; for other coolants, refer to the SINAMICS S120 Manual.
7) Max. cable lengths in conjunction with Active Interface Module and Basic Line Filter (Category C3 in accordance with EN 61800-3).
8) The fan is supplied with the Active Line Module and must be installed before the Active Line Module is commissioned.
9) Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and are to be dimensioned accordingly.