Braking resistors for chassis format Siemens

Обзор



The excess energy of the DC link is dissipated via the braking resistor.

The braking resistor is connected to a Braking Module. The braking resistor is positioned outside the cabinet or switchgear room. This arrangement enables the resulting heat losses to be dissipated, thereby allowing a corresponding reduction in the level of air conditioning required.

2 braking resistors with different rated and peak power values are available for chassis format units.

The braking resistor is monitored on the basis of the mark-space ratio. A temperature switch (NC contact) is also fitted. This responds when the maximum permissible temperature is exceeded and can be evaluated by a controller.

Характеристика



Load diagram for Braking Module and braking resistor in chassis format

Технические данные



DC link voltage 510 ... 720 V DC

Braking resistor

 

6SL3000‑1BE31‑3AA0

6SL3000‑1BE32‑5AA0

Resistance

Ω 

4.4

2.2

Rated power PDB

kW

25

50

Peak power Pmax

kW

125

250

Load duration

for peak output

s

15

15

Cycle duration

of braking duty cycle

s

90

90

Current, max.

A

189

378

Cable entry

 

Via M50 cable gland

Via M50 cable gland

Power connection

 

Via M10 stud

Via M10 stud

  • Conductor cross-section, max.

mm2

50

70

Degree of protection

 

IP20

IP20

Dimensions

 

 

 

  • Width

mm (in)

740 (29.1)

810 (31.9)

  • Height

mm (in)

605 (23.8)

1325 (52.2)

  • Depth

mm (in)

485 (19.1)

485 (19.1)

Weight, approx.

kg (lb)

50 (110)

120 (265)

Approvals, according to

 

cURus

cURus

Suitable for Braking Module in chassis format

Type

6SL3300‑1AE31‑3AA0

6SL3300‑1AE32‑5 . A0



DC link voltage 675 ... 900 V DC

Braking resistor

 

6SL3000‑1BF31‑3AA0

6SL3000‑1BF32‑5AA0

Resistance

Ω 

6.8

3.4

Rated power PDB

kW

25

50

Peak power Pmax

kW

125

250

Load duration

for peak output

s

15

15

Cycle duration

of braking duty cycle

s

90

90

Current, max.

A

153

306

Cable entry

 

Via M50 cable gland

Via M50 cable gland

Power connection

 

Via M10 stud

Via M10 stud

  • Conductor cross-section, max.

mm2

50

70

Degree of protection

 

IP20

IP20

Dimensions

 

 

 

  • Width

mm (in)

740 (29.1)

810 (31.9)

  • Height

mm (in)

605 (23.8)

1325 (52.2)

  • Depth

mm (in)

485 (19.1)

485 (19.1)

Weight, approx.

kg (lb)

50 (110)

120 (265)

Approvals, according to

 

cURus

cURus

Suitable for Braking Module in chassis format

Type

6SL3300‑1AF31‑3AA0

6SL3300‑1AF32‑5 . A0



DC link voltage 890 ... 1035 V DC

Braking resistor

 

6SL3000‑1BH31‑3AA0

6SL3000‑1BH32‑5AA0

Resistance

Ω 

9.8

4.9

Rated power PDB

kW

25

50

Peak power Pmax

kW

125

250

Load duration

for peak power

s

15

15

Cycle duration

of braking duty cycle

s

90

90

Current, max.

A

125

255

Cable entry

 

Via M50 cable gland

Via M50 cable gland

Power connection

 

Via M10 stud

Via M10 stud

  • Conductor cross-section, max.

mm2

50

70

Degree of protection

 

IP20

IP20

Dimensions

 

 

 

  • Width

mm (in)

740 (29.1)

810 (31.9)

  • Height

mm (in)

605 (23.8)

1325 (52.2)

  • Depth

mm (in)

485 (19.1)

485 (19.1)

Weight, approx.

kg (lb)

50 (110)

120 (265)

Approvals, according to

 

Suitable for Braking Module in chassis format

Type

6SL3300‑1AH31‑3AA0

6SL3300‑1AH32‑5 . A0