Braking resistors for blocksize format Siemens

Обзор



Braking resistor for blocksize format, frame sizes FSA and FSC

The PM340 Power Modules cannot regenerate into the line supply. For regenerative operation, e.g. the braking of a rotating mass, a braking resistor must be connected to convert the resulting energy into heat.

The braking resistor is connected at terminals DCP/R1 and R2.

The braking resistors can be installed at the side next to the PM340 Power Modules. The braking resistors for the FSA and FSB frame sizes are designed as base components. If the PM340 Power Modules of the FSA or FSB frame sizes are operated without line reactor, the braking resistors can also be installed under the Power Modules.

The braking resistors for the Power Modules of the FSC to FSF frame sizes should be placed outside the control cabinet or the switchgear room in order to lead the resulting heat loss away from the Power Modules, thereby allowing a reduction in the level of air conditioning required.

The braking resistors are designed with a temperature switch. The temperature switch must be evaluated to prevent consequential damage if the braking resistor overheats.

Характеристика



Load diagram for braking resistors in blocksize format

ta = 12 s

t = 240 s

Технические данные



DC link voltage 240 ... 360 V DC

Braking resistor

 

6SE6400-4BC05-0AA0

Resistance

180 Ω

Rated power PDB

0.05 kW

Peak power Pmax

1 kW

Degree of protection 1)

IP20

Power connections

3 × 1.5 mm2 (shielded)

  • Length

0.5 m (1.64 ft)

Thermostatic switch (NC contact)

 

  • Switching capacity

250 V AC/max. 2.5 A

  • Conductor cross-section

0.5 … 2.5 mm2

Dimensions

 

  • Width

72 mm (2.83 in)

  • Height

230 mm (9.06 in)

  • Depth

43.5 mm (1.71 in)

Weight, approx.

1.0 kg (2 lb)

Approvals, according to

cURus

Suitable for Power Module in blocksize format

Frame size FSA



1) With correctly connected load connection cable.

DC link voltage 510 ... 720 V DC

Braking resistor

 

6SE6400-4BD11‑0AA0

6SL3201-0BE12‑0AA0

6SE6400-4BD16‑5CA0

6SE6400-4BD21‑2DA0

6SE6400-4BD22‑2EA1

6SE6400-4BD24‑0FA0

Resistance

Ω 

390

160

56

27

15

8.2

Rated power PDB

kW

0.1

0.2

0.65

1.2

2.2

4.0

Peak power Pmax

kW

1.7

4.1

12

24

44

80

Degree of protection 1)

 

IP20

IP20

IP20

IP20

IP20

IP20

Power connections

 

3 × 1.5 mm2 (shielded)

3 × 1.5 mm2 (shielded)

3 × 1.5 mm2 (shielded)

M6 screw stud

M6 screw stud

M6 screw stud

  • Length

m (ft)

0.5 (1.64)

0.5 (1.64)

0.9 (2.95)

Thermostatic switch (NC contact)

 

 

 

 

 

 

 

  • Switching capacity

 

250 V AC/
max. 2.5 A

250 V AC/
max. 2.5 A

250 V AC/
max. 2.5 A

250 V AC/
max. 2.5 A

250 V AC/
max. 2.5 A

250 V AC/
max. 2.5 A

  • Conductor cross-section

mm2

0.5 … 2.5

0.5 … 2.5

0.5 … 2.5

0.5 … 2.5

0.5 … 2.5

0.5 … 2.5

Dimensions

 

 

 

 

 

 

 

  • Width

mm (in)

72 (2.83)

153 (6.02)

185 (7.28)

270 (10.6)

301 (11.8)

400 (15.7)

  • Height

mm (in)

230 (9.05)

329 (12.9)

285 (11.2)

515 (20.3)

483 (19.0)

650 (25.6)

  • Depth

mm (in)

43.5 (1.71)

43.5 (1.71)

150 (5.91)

175 (6.89)

326 (12.83)

315 (12.4)

Weight, approx.

kg (lb)

1.0 (2)

1.6 (3.5)

3.8 (8)

7.4 (16)

10.6 (23)

16.7 (37)

Approvals, according to

 

cURus

cURus

cURus

cURus

cURus

cURus

Suitable for Power Module in blocksize format

Frame size

FSA

FSB

FSC

FSD

FSE

FSF



1) With correctly connected load connection cable.