SINAMICS S120 Combi Power Modules Siemens
Обзор
SINAMICS S120 Combi Power Module
SINAMICS S120 Combi is a very compact and rugged drive concept tailored for compact turning and milling machines. SINAMICS S120 Combi integrates a line infeed with regenerative feedback capability, power units for spindle and feed motors as well as a TTL encoder interface into a single Power Module.
The SINAMICS S120 Combi Power Modules are optimized as a drive for machine tools with 3 to 6 axes. The Power Modules are available with external air cooling. SINAMICS Motor Modules in the booksize compact format are used as expansion axes.
Функции
- Power Module with 3 or 4 integrated power units
- Integrated line infeed with regenerative feedback capability
- Integrated TTL encoder interface
- Integrated motor brake control for one axis
- Integrated fan power supply
- Line connection voltage 380 to 480 V 3 AC
- Supply types TT, TN and IT
- Integrated shield terminals
- Heat dissipation concept with an external heatsink for extremely low power loss in the control cabinet
- Easy-to-mount fan module optimized for harsh environments
- Increased availability thanks to fan monitoring
- Derating only from 45 °C cabinet temperature
- Power cable are connected by means of screw-type terminals
Интеграция
The following components can be connected to the SINAMICS S120 Combi drive system:
- SINUMERIK 828D BASIC
- SINUMERIK 828D
- 3 or 4 spindles/feed motors
- 3 or 4 motor encoders
- 3 or 4 direct encoders via DMC20
- Direct spindle encoder with TTL directly or sin/cos via SMC20
- External fan module
- Up to two additional SINAMICS S120 Motor Modules in booksize compact format via DC link connection and 24 V DC busbars
- Braking Module with braking resistor via DC link connection
- Control Supply Module via DC link connection and 24 V DC busbars
- One safe motor brake control
- 5 or 6 DRIVE‑CLiQ sockets
- 24 V electronics power supply via connector
- 1 safe standstill input for the infeed (Enable Pulses)
- 1 safe standstill input for the spindle and feeds (Enable Pulses)
- 1 temperature sensor input for the spindle (KTY84‑130 or PTC)
- PE/protective conductor connections
The scope of supply of the SINAMICS S120 Combi Power Modules includes:
- SINAMICS S120 Combi Power Module
- Accessories pack consisting of:
- 4 DRIVE‑CLiQ dust-proof blanking plugs
- Connector X224 for the electronics power supply
- Connector X11 for motor brake control
- Connector X21 Enable Pulses infeed
- Connector X22 Enable Pulses drives/temp.
- 5 shield terminals for power cables
- Shield terminal for signal cable
Особенности
- Compact multi-axis module with line infeed with regenerative feedback capability and power units for 3 or 4 axes
- Customized drive system for compact standard turning and milling machines
- Requires very little mounting space in control cabinet
(incl. fan module, shield terminals and ventilation clearances) - Optimized for weak supply networks with frequent undervoltage, network imbalances and large frequency fluctuations
- Optimized for harsh operating conditions with increased cabinet temperature and increased humidity
- Rugged Power Modules resistant to short circuits, overvoltage and ground faults
- Rugged and easy-to-fit screw-type terminals with integrated shield connection for the power cables
- Perfect expandability using additional Motor Modules in booksize compact format
- Low energy consumption thanks to state-of-the-art 400-V technology
- Excellent dynamic response and machining precision thanks to Dynamic Servo Control (DSC)
- Simple cabling due to intelligent DRIVE-CLiQ interface
- Very simple commissioning thanks to predefined topologies
Технические данные
Article No. | 6SL3111-3VE2.-....6SL3111-4VE2.-.... |
Product brand name | SINAMICS |
Product type designation | S120 Combi |
Product designation | Power Module |
DC link voltage | 1.35 × line voltage1) |
Output voltage | 0 ... 0.7 × DC link voltage1) |
Line power factor at rated power | |
| > 0.96 |
| 0.64 ... 0.90 |
Radio interference suppression | |
| No radio interference suppression |
| Category C2 according to EN 61800-3 |
Degree of protection | IP20 |
Installation altitude | Up to 1000 m (3281 ft) above sea level without derating, |
Certificate of suitability | CE, cURus |
Safety Integrated | Safety Integrity Level 2 (SIL 2) acc. to IEC 61508 |
1) The DC link voltage adjusts itself to the mean value of the rectified line voltage.
Article No. | 6SL3111-3VE21-6FA0 | 6SL3111-3VE21-6EA0 | 6SL3111-3VE22-0HA0 | |
Product designation | 3-axis Power Module with external air cooling | |||
Infeed | ||||
| kW | 16 | 16 | 20 |
| kW | 21 | 21 | 26,5 |
| kW | 35 | 35 | 40 |
Regenerative feedback | ||||
| kW | 16 | 16 | 20 |
| kW | 35 | 35 | 40 |
Supply voltages | ||||
| V | 380 -10 % ... 480 +10 % | 380 -10 % ... 480 +10 % | 380 -10 % ... 480 +10 % |
| Hz | 45 ... 66 | 45 ... 66 | 45 ... 66 |
| V | 24 (20.4 ... 28.8) | 24 (20.4 ... 28.8) | 24 (20.4 ... 28.8) |
Rated input current | ||||
| A | 28 | 28 | 34 |
| A | 29 | 29 | 35 |
| A | 25 | 25 | 30 |
| A | 35.5 | 35.5 | 44 |
| A | 56 | 56 | 63,5 |
Pulse frequency | kHz | 4 | 4 | 4 |
Output voltage AC | V | 0 ... 0.7 × DC link voltage | 0 ... 0.7 × DC link voltage | 0 ... 0.7 × DC link voltage |
Spindle | ||||
| A | 18 | 24 | 30 |
| A | 15.3 | 20.4 | 25.5 |
| A | 24 | 32 | 40 |
| A | 36 | 48 | 56 |
Rated power | ||||
| kW | 8.7 | 11.7 | 14.4 |
| kW | 9.7 | 13 | 16 |
Feedrate 1/Feedrate 2 | ||||
| A | 5 | 9 | 9 |
| A | 4.3 | 7.7 | 7.7 |
| A | 6.5 | 12 | 12 |
| A | 10 | 18 | 18 |
Rated power | ||||
| kW | 2.4 | 4.3 | 4.3 |
| kW | 2.7 | 4.8 | 4.8 |
Output for expansion axis | ||||
| A | 40 | 40 | 40 |
| V | 460 ... 720 | 460 ... 720 | 460 ... 720 |
| A | 20 | 20 | 20 |
Electronics current consumption at 24 V DC | ||||
| A | 1.5 | 1.5 | 1.5 |
| A | 2.3 | 2.3 | 2.3 |
Total power loss, | W | 425 | 537 | 634 |
| W | 81 | 91 | 102 |
| W | 344 | 446 | 532 |
Ambient temperature, max. | ||||
| °C (°F) | 45 (113) | 45 (113) | 45 (113) |
| °C (°F) | 55 (131) | 55 (131) | 55 (131) |
DC link voltage | V | 460 ... 720 | 460 ... 720 | 460 ... 720 |
| V | 820 ± 2 % | 820 ± 2 % | 820 ± 2 % |
| V | 380 ± 2 % | 380 ± 2 % | 380 ± 2 % |
DC link capacitance | μF | 1645 | 1880 | 2115 |
Circuit breaker (UL) | ||||
| 3VL2105-2KN30-.... | 3VL2105-2KN30-.... | 3VL2106-2KN30-.... | |
| A | 35 | 35 | 60 |
| kA | 65 | 65 | 65 |
Safety fuses (UL) | ||||
| AJT35 | AJT35 | AJT60 | |
| A | 35 | 35 | 60 |
| ||||
| kA | 65 | 65 | 65 |
| kA | 200 | 200 | 200 |
Cooling air requirement | m3/h (ft3/h) | 160 (5650) | 160 (5650) | 160 (5650) |
Width | mm (in) | 260 (10.23) | 260 (10.23) | 260 (10.23) |
Height | mm (in) | 380 (14.96) | 380 (14.96) | 380 (14.96) |
Depth | mm (in) | 304 (11.97) | 304 (11.97) | 304 (11.97) |
Net weight | kg (lb) | 18.35 (40.45) | 18.4 (40.56) | 18.5 (40.78) |
Article No. | 6SL3111-4VE21-0EA0 | 6SL3111-4VE21-6FA0 | 6SL3111-4VE21-6EA0 | 6SL3111-4VE22-0HA0 | |
Product designation | 4-axis Power Module with external air cooling | ||||
Infeed | |||||
| kW | 10 | 16 | 16 | 20 |
| kW | 13 | 21 | 21 | 26.5 |
| kW | 35 | 35 | 35 | 40 |
Regenerative feedback | |||||
| kW | 10 | 16 | 16 | 20 |
| kW | 35 | 35 | 35 | 40 |
Supply voltages | |||||
| V | 380 -10 % ... 480 +10 % | 380 -10 % ... 480 +10 % | 380 -10 % ... 480 +10 % | 380 -10 % ... 480 +10 % |
| Hz | 45 ... 66 | 45 ... 66 | 45 ... 66 | 45 ... 66 |
| V | 24 (20.4 ... 28.8) | 24 (20.4 ... 28.8) | 24 (20.4 ... 28.8) | 24 (20.4 ... 28.8) |
Rated input current | |||||
| A | 16.2 | 28 | 28 | 34 |
| A | 17 | 29 | 29 | 35 |
| A | 12.8 | 25 | 25 | 30 |
| A | 21.1 | 35,5 | 35,5 | 44 |
| A | 56.7 | 56 | 56 | 63.5 |
Pulse frequency | kHz | 4/8 | 4 | 4 | 4 |
Output voltage AC | V | 0 ... 0.7 × DC link voltage | 0 ... 0.7 × DC link voltage | 0 ... 0.7 × DC link voltage | 0 ... 0.7 × DC link voltage |
Spindle | |||||
| A | 24 | 18 | 24 | 30 |
| A | 20.4 | 15.3 | 20.4 | 25.5 |
| A | 32 at 4 kHz | 24 | 32 | 40 |
| A | 60 | 36 | 48 | 56 |
Rated power | |||||
| kW | 11.7 | 8.7 | 11.7 | 14.4 |
| kW | 13 | 9.7 | 13 | 16 |
Feedrate 1 | |||||
| A | 12 | 9 | 9 | 12 |
| A | 10.8 | 7.7 | 7.7 | 10.3 |
| A | 16 | 12 | 12 | 16 |
| A | 36 | 18 | 18 | 24 |
Rated power | |||||
| kW | 5.8 | 4.3 | 4.3 | 5.8 |
| kW | 6.5 | 4.8 | 4.8 | 6.5 |
Feedrate 2/Feedrate 3 | |||||
| A | 12 | 5 | 9 | 9 |
| A | 10.8 | 4.3 | 7.7 | 7.7 |
| A | 16 | 6.5 | 12 | 12 |
| A | 36 | 10 | 18 | 18 |
Rated power | |||||
| kW | 5.8 | 2.4 | 4.3 | 4.3 |
| kW | 6.5 | 2.7 | 4.8 | 4.8 |
Output for expansion axis | |||||
| A | 18.5 | 40 | 40 | 40 |
| V | 510 ... 720 | 510 ... 720 | 510 ... 720 | 510 ... 720 |
| A | 5 | 20 | 20 | 20 |
Electronics current consumption at 24 V DC | |||||
| A | 1.6 | 1.6 | 1.6 | 1.6 |
| A | 2.4 | 2.4 | 2.4 | 2.4 |
Total power loss, incl. electronics losses | W | 770 | 492 | 607 | 733 |
| W | 115 | 87 | 100 | 113 |
| W | 655 | 405 | 507 | 620 |
Ambient temperature, max. | |||||
| °C (°F) | 45 (113) | 45 (113) | 45 (113) | 45 (113) |
| °C (°F) | 55 (131) | 55 (131) | 55 (131) | 55 (131) |
DC link voltage | V | 460 ... 720 | 460 ... 720 | 460 ... 720 | 460 ... 720 |
| V | 820 ± 2 % | 820 ± 2 % | 820 ± 2 % | 820 ± 2 % |
| V | 380 ± 2 % | 380 ± 2 % | 380 ± 2 % | 380 ± 2 % |
DC link capacitance | μF | 2520 | 1645 | 2115 | 2520 |
Circuit breaker (UL) | |||||
| 3VL2505-2KN30-.... | 3VL2505-2KN30-.... | 3VL2505-2KN30-.... | 3VL2506-2KN30-.... | |
| A | 50 | 50 | 50 | 60 |
| kA | 65 | 65 | 65 | 65 |
Safety fuses (UL) | |||||
| AJT35 | AJT35 | AJT35 | AJT60 | |
| A | 35 | 35 | 35 | 60 |
| |||||
| kA | 65 | 65 | 65 | 65 |
| kA | 200 | 200 | 200 | 200 |
Cooling air requirement | m3/h (ft3/h) | 160 (5650) | 160 (5650) | 160 (5650) | 160 (5650) |
Width | mm (in) | 260 (10.23) | 260 (10.23) | 260 (10.23) | 260 (10.23) |
Height | mm (in) | 380 (14.96) | 380 (14.96) | 380 (14.96) | 380 (14.96) |
Depth | mm (in) | 304 (11.97) | 304 (11.97) | 304 (11.97) | 304 (11.97) |
Net weight | kg (lb) | 19.4 (42.8) | 18.9 (41.7) | 19 (42) | 19 (42) |