Single Motor Modules in booksize compact format Siemens

Дизайн



Single Motor Modules in booksize compact format

The Single Motor Modules in booksize compact format feature the following connections and interfaces as standard:

  • 2 DC link connections via integrated DC link busbars
  • 1 electronics power supply connection via integrated 24 V DC busbars
  • 3 DRIVE‑CLiQ sockets
  • 1 motor connection via connector
  • 1 safe standstill input (enable pulses)
  • 1 safe motor brake control
  • 1 temperature sensor input (KTY84‑130 or PTC)
  • 2 PE (protective earth) connections

The status of the Motor Modules is indicated via two multi-color LEDs.

The shield of the motor cable is routed over the connector to the motor connection.

The signal cable shield can be connected to the Motor Module by means of a shield connection terminal, e.g. Weidmüller type KLBÜ 3-8 SC.

The scope of supply of the Motor Modules includes:

  • DRIVE‑CLiQ cable (length depends on module width) to connect Motor Module to adjacent Motor Module
    length 0.11 m (4.33 in) for 50 mm (1.97 in) wide Motor Modules or
    length 0.16 m (6.3 in) for 75 mm (2.95 in) wide Motor Modules.
  • 2 blanking plugs for sealing unused DRIVE‑CLiQ sockets
  • Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
  • Connector X21
  • Connector X11 for motor brake connection
  • Connector X1 for motor connection
  • 1 set of warning signs in 30 languages
  • 1 heat conducting foil

Характеристика



Overload capability

Peak current duty cycle with full load (300% overload)

 

Note:

Imax stands for 2 x Irated in the following overload characteristics.

Load cycle with previous load

Load cycle without previous load

S6 load cycle with previous load with a load cycle period of 600 s

S6 load cycle with previous load with a load cycle period of 60 s

Load cycle with 60 s overload with a load cycle period of 300 s

Load cycle with 30 s overload with a load cycle period of 300 s

Derating characteristics

3 A and 5 A Single Motor Modules in booksize compact format

Output current dependent on pulse frequency

9 A and 18 A Single Motor Modules in booksize compact format

Output current dependent on pulse frequency

Output current dependent on ambient temperature

Output current dependent on installation altitude

Voltage derating dependent on installation altitude

Output current dependent on output frequency

Интеграция



Single Motor Modules communicate with the Control Unit via DRIVE‑CLiQ.

Connection example of Single Motor Module in booksize compact format

Технические данные



Single Motor Module in booksize compact format

6SL3420-1TE...

 

DC link voltage

(up to 2000 m (6562 ft) above sea level)

510 ... 720 V DC
(line voltage 380 ... 480 V 3 AC)

Output frequency

 

  • Control type Servo

0 ... 650 Hz 1) 2)

  • Control type Vector

0 ... 300 Hz 1)

  • Control type V/f

0 ... 600 Hz 1) 2)

Electronics power supply

24 V DC -15 %/+20 %

Type of cooling

Internal air cooling (power units with increased air cooling by built-in fan)

Cold plate cooling

Permissible ambient and coolant temperature (air)

during operation for line-side components, Line Modules and Motor Modules

0 ... 40 °C (32 ... 104 °F) without derating,
> 40 ... 55 °C (104 ... 131 °F), see derating characteristics

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 ... 4000 m (3281 ... 13124 ft) above sea level, see derating characteristics

Declarations of conformity

CE (Low-Voltage and EMC Directives)

Approvals, according to

UL-recognized

Safety Integrated

Safety Integrity Level 2 (SIL 2) acc. to IEC 61508, Performance Level d (PL d) acc. to ISO 13849‑1 and Control Category 3 acc. to ISO 13849‑1 or EN 954‑1

For further information, see section Safety Integrated..



1) Note the correlation between max. output frequency, pulse frequency and current derating.For more information, see section System description - Dimensioning.

2) The output frequency is currently limited to 550 Hz. The specified values apply to systems with license for high output frequency. For further information, refer to section Control Units and http://support.automation.siemens.com/WW/view/en/104020669

 

DC link voltage 510 ... 720 V DC

Single Motor Module in booksize compact format

  • Internal air cooling/
    cold plate cooling

6SL3420-1TE13-0AA1

6SL3420-1TE15-0AA1

6SL3420-1TE21-0AA1

6SL3420-1TE21-8AA1

Output current

 

 

 

 

 

  • Rated current Irated

A

3

5

9

18

  • Base-load current IH

A

2.6

4.3

7.7

15.3

  • For S6 duty (40 %) IS6

A

3.5

6

10

24

  • Imax

A

9

15

27

54

Type rating 1)

 

 

 

 

 

  • Based on Irated

kW (HP)

1.6 (1.5)

2.7 (3)

4.8 (5)

9.7 (10)

  • Based on IH

kW (HP)

1.4 (1)

2.3 (2.5)

4.1 (5)

8.2 (10)

Rated pulse frequency

kHz

8

8

4

4

DC link current Id2)

A

3.6

6

11

22

Current carrying capacity

 

 

 

 

 

  • DC link busbars

A

100

100

100

100

  • 24 V DC busbars 3)

A

20

20

20

20

DC link capacitance

μF

110

110

110

235

Power requirement

At 24 V DC, max.

A

0.85

0.85

0.85

0.85

Power loss

 

 

 

 

 

  • With internal air cooling in control cabinet 4)

kW

0.07

0.1

0.1

0.18

  • With cold plate cooling, int./ext.

kW

0.026/0.04

0.031/0.065

0.031/0.065

0.051/0.095

Cooling air requirement

m3/s (ft3/s)

0.008 (0.3)

0.008 (0.3)

0.008 (0.3)

0.008 (0.3)

Thermal resistance Rth

K/W

0.25

0.25

0.25

0.16

Sound pressure level LpA (1 m)

dB

<60

<60

<60

<60

Motor connection

U2, V2, W2

 

Connector (X1) with screw-type terminals

Connector (X1) with screw-type terminals

Connector (X1) with screw-type terminals

Connector (X1) with screw-type terminals

  • Conductor cross-section

mm2

0.2 ... 6

0.2 ... 6

0.2 ... 6

0.2 ... 6

Shield connection

 

Integrated in connector (X1)

Integrated in connector (X1)

Integrated in connector (X1)

Integrated in connector (X1)

PE connection

 

M5 screw

M5 screw

M5 screw

M5 screw

Motor brake connection

 

Connector (X11),
24 V DC, 2 A

Connector (X11),
24 V DC, 2 A

Connector (X11),
24 V DC, 2 A

Connector (X11),
24 V DC, 2 A

Motor cable length, max.

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

70 (230)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

100 (328)

Degree of protection

 

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

  • Width

mm (in)

50 (1.97)

50 (1.97)

50 (1.97)

75 (2.95)

  • Height

mm (in)

270 (10.63)

270 (10.63)

270 (10.63)

270 (10.63)

  • Depth

mm (in)

226 (8.90)

226 (8.90)

226 (8.90)

226 (8.90)

Weight, approx.

kg (lb)

2.7 (5.95)

2.7 (5.95)

2.7 (5.95)

3.4 (7.50)



1) Rated power of a typical standard asynchronous (induction) motor at 600 V DC link voltage.

2) Rated DC link current for dimensioning an external DC connection.For DC link current calculation for dimensioning the Line Module, see chapter System description – Dimensioning.

3) If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A, an additional 24 V DC connection using a 24 V terminal adapter is required (max. cross-section 6 mm2, max. fuse protection 20 A).

4) Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.