1PH8 for SINAMICS S120 for machine tools Siemens
Область применения
- Compact machine tools
- Complex machining centers and turning machines
- Fully encapsulated milling machines
- High-load milling spindles
- Counterspindles or power tools for turning machines
- Direct power tools with internal cooling
- Special-purpose machines
Обзор
The SIMOTICS M-1PH8 motors are compact asynchronous motors with a squirrel-cage rotor and degree of protection IP55/IP65. They extend and replace the current power spectrum of our proven 1PH/1PM series. The 1PH8 motors are available in two different cooling types:
- Forced ventilation
- Water cooling
These motors have been designed specifically for use in conjunction with the SINAMICS S120 drive system. Depending on the control requirements, appropriate encoder systems are available for the motors for sensing the motor speed and indirect position.
As a standard, the encoder system for machine tools is C axis capable, an additional encoder for C axis mode is not necessary.
Характеристика
Typical speed/power graph for 1PH8 asynchronous motors1)
The graph shows the typical relationship between motor speed and drive power for SIMOTICS M-1PH8 motors for S1 duty (continuous duty) in accordance with IEC 60034-1.
Data for S2 short-time duty and S6 continuous duty can be found in the 1PH8 Motors Configuration Manual.
1) For further configuration information, see the 1PH8 Motors Configuration Manual.
Конфигурация
Ordering example
Selection criteria | Version | Structure of the order number |
---|---|---|
1PH8 motor | Shaft height 80 | 1PH8083-. . . . . - . . .1 |
Asynchronous version without brake | 1PH8083-1 . . . . - . . .1 | |
Encoder system | Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (encoder IC2048S/R) | 1PH8083-1M . . .- . . .1 |
Rated speed | 1500 rpm | 1PH8083-1MF . . - . . .1 |
Cooling | Water cooling | 1PH8083-1MF2 . - . . .1 |
Type of construction | IM B3 (IM V5, IM V6) | 1PH8083-1MF20- . . .1 |
Shaft extension DE | Plain shaft | 1PH8083-1MF20-0 . .1 |
Bearing version | Standard | 1PH8083-1MF20-0B .1 |
Connection | Power connection terminal box top | 1PH8083-1MF20-0BA1 |
Options | 1PH8083-1MF20-0BA1-Z | |
Additional PTC thermistor chain for alarm and tripping | 1PH8083-1MF20-0BA1-Z | |
Special paint finish worldwide: Primer and paint finish sky blue RAL 5015 | 1PH8083-1MF20-0BA1-Z |
Особенности
- Wide range of power ratings
- The right design for any application
- Forced ventilation or water cooling
- Solid shaft or hollow shaft
- Various bearing concepts
- Different encoder types for closed-loop speed control and high-precision positioning
- Excellent performance features
- Maximum speeds of up to 20000 rpm
- Excellent rotational accuracy of up to 10 μm
- Excellent vibration severity
- High dynamic response (short acceleration times)
- Low noise emission
- Simple, flexible connection system
- Commissioning with electronic rating plate and DRIVE-CLiQ interface
Water cooling always brings benefits:
- With applications in which extreme ambient conditions, such as high temperatures, dust, dirt, or a corrosive atmosphere, do not permit air cooling
- In processes in which the environment must not be heated
Технические данные
SIMOTICS M-1PH8 motor | ||
---|---|---|
Cooling | Forced ventilation | Water cooling |
| ‑ | 6 bar |
| ||
| ‑ | 6 l/min (1.59 US gallons/min.) |
| ‑ | 8 l/min (2.11 US gallons/min.) |
| ‑ | 12 l/min (3.17 US gallons/min.) |
| 15 l/min (3.96 US gallons/min.) | |
| ‑ | 15 l/min (3.96 US gallons/min.) |
| ‑ | 20 l/min (5.28 US gallons/min.) |
| ‑ | 35 l/min (9.25 US gallons/min.) |
| ‑ | |
| ‑ | G 1/8“ |
| ‑ | G 1/4“ |
| ‑ | G 3/8“ |
| ‑ | G 1/2“ |
| ‑ | G 3/8“ |
| ‑ | G 3/8“ |
| ‑ | G 1/2“ |
Ambient temperature, permissible | -15 ... +40 °C (5 ... 104 °F) | |
Coolant inlet temperature | ‑ | < 30 °C (86 °F) |
Temperature monitoring | KTY 84 temperature sensor in the stator winding | |
| Additional KTY 84 as spare | |
Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) | For an ambient temperature of up to 40 °C (104 °F) | For a coolant inlet temperature of up to 30 °C (86 °F) |
Motor fan ratings | ‑ | |
| 230 V 1 AC 50/60 Hz, 265 V 1 AC 60 Hz 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz 200 V ... 277 V 1 AC 50/60 Hz (EC fan) 400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz | - - - - |
Encoder system, built-in | Without DRIVE-CLiQ interface or with DRIVE-CLiQ interface | |
Sound pressure level LpA (1 m) | Rated pulse frequency 4 kHz | Rated pulse frequency 4 kHz/2 kHz2) |
| 70 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm | 68 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm |
| 73 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm | 69 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm |
| 73 dB at a rated pulse frequency of 2 kHz and a speed range: Forced ventilation (IP55) 1PH818 up to 5000 rpm 1PH822 up to 4500 rpm | 70 dB at a rated pulse frequency of 2 kHz or 4 kHz and a speed range: 1PH818 up to 5000 rpm 1PH822 up to 4500 rpm |
| 74 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm: Forced ventilation (IP55) 1PH828 up to 3300 rpm | 72 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm |
Connection | ||
| Power connector or terminal box | |
| Terminal box | Terminal box |
| ||
| Power connector | ‑ |
| Power connector or terminal box | ‑ |
| Terminal box | - |
| Connector for signals (without mating connector) or DRIVE-CLiQ | |
Vibration severity | In accordance with Siemens/EN 60034-14 (IEC 60034-14) | |
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)2) | Tolerance R | |
Degree of protection in accordance with EN 60034-5 (IEC 60034-5) | ||
| IP55 | IP65 |
| IP55 | IP55 |
| IP55, option IP74: IP65 | ‑ |
Rating plate | 1 unit attached to motor | |
Paint finish | Anthracite RAL 7016 | |
Approvals, according to | cURus |
1) DE is the drive end with shaft. NDE is the non-drive end.
2) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft..
S/R = signals/revolution