Signal cables for SINUMERIK Siemens
Область применения
DRIVE‑CLiQ signal cables
DRIVE-CLiQ signal cables are used to connect components with DRIVE-CLiQ connections which have a separate or external 24 V DC power supply.
MOTION‑CONNECT DRIVE‑CLiQ signal cables
MOTION‑CONNECT DRIVE‑CLiQ signal cables with 24 V DC cores are used whenever components with DRIVE-CLiQ connections must meet high requirements such as mechanical stress and oil resistance, e.g. where a connection is made outside the cabinet between Power Modules/Motor Modules and SIMOTICS S-1FK7/SIMOTICS M-1PH8 motors with DRIVE-CLiQ interface.
MOTION-CONNECT pre-assembled signal cables
MOTION-CONNECT pre-assembled signal cables are used whenever motor encoders on motors without DRIVE-CLiQ interface are connected to Sensor Modules.
Обзор
MOTION‑CONNECT DRIVE‑CLiQ signal cable with IP20/IP67 connector
Signal cables are pre-assembled and are sold by the meter for the connection of a variety of components.
The following different types of cable are available:
- DRIVE‑CLiQ signal cables
- MOTION‑CONNECT DRIVE‑CLiQ signal cables
- MOTION‑CONNECT pre-assembled signal cables
Дизайн
If pre-assembled signal cables are to be installed in a cable carrier in such a way that the connector would inhibit assembly, pre-assembled cables without assembled connector can also be supplied. In this case, the contacts of the cables are crimped and the connector enclosure is supplied separately. After installing the cables, the customer assembles the connector enclosure.
The 6FX.002‑2....‑.... signal cables are available with crimped contacts and with the connector enclosure supplied separately (not in the case of DRIVE‑CLiQ signal cables and signal cables with exposed core ends).
Signal cables with enclosed connector enclosure for the motor end. In this case, the 6th position of the Article No. must be changed from 0 to 4:
6FX.042‑2C...‑.... (not in the case of signal cables for connection via terminals or 6FX7002‑2SL01‑…., 6FX7002‑2SL02‑….).
Signal cables with enclosed connector enclosure for the module end. In this case, the 6th position of the Article No. must be changed from 0 to 1:
6FX.012‑2C...‑.... (not in the case of signal cables for connection via terminals or 6FX.002-2AH00-…., 6FX7002-2SL20-….).
Once the contacts have latched into the insulator, they can no longer be removed.
Type of delivery for pre-assembled signal cables
Pre-assembled signal cables are available in units of 10 cm (3.94 in).
The cables are supplied on reels up to 30 kg or 100 m (66.2 lb or 328 ft). Above 30 kg or 100 m (66.2 lb or 328 ft), cable drums are used instead of reels.
Технические данные
DRIVE‑CLiQ signal cables | DRIVE‑CLiQ | DRIVE‑CLiQ MOTION‑CONNECT 500 | DRIVE‑CLiQ MOTION‑CONNECT 800PLUS |
---|---|---|---|
| 6FX2...‑1DC..‑.... | 6FX5...‑.DC..‑.... | 6FX8...‑.DC..‑.... |
Approvals, according to | |||
| UL STYLE 2502/CSA-N.210.2-M90 | UL STYLE 2502/CSA-N.210.2-M90 | UL STYLE 20236/CSA-N.210.2-M90 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Rated voltage according to EN 50395 | 30 V | 30 V | 30 V |
Test voltage, rms | 500 V | 500 V | 500 V |
Operating temperature on the surface | |||
| ‑20 … +80 °C (‑4 ... +176 °F) | ‑20 … +80 °C (‑4 ... +176 °F) | ‑20 … +80 °C (‑58 ... +176 °F) |
| – | 0 … 60 °C (+32 ... +140 °F) | ‑20 … +60 °C (‑4 ... +140 °F) |
Tensile stress, max. | |||
| 45 N/mm2 (6526 lbf/in2) | 80 N/mm2 (11603 lbf/in2) | 50 N/mm2 (7252 lbf/in2) |
| – | 30 N/mm2 (4351 lbf/in2) | 20 N/mm2 (2901 lbf/in2) |
Smallest bending radius | |||
| 50 mm (1.97 in) | 35 mm (1.38 in) | 35 mm (1.38 in) |
| – | 125 mm (4.92 in) | 75 mm (2.95 in) |
Torsional stress | – | Absolute 30°/m | Absolute 30°/m |
Bending | – | 100000 | 10 million |
Traversing velocity | – | 30 m/min (98.4 ft/min) | 300 m/min (984 ft/min) |
Acceleration | – | 2 m/s2 (6.56 ft/s2) | Up to 50 m/s2 (164 ft/s2) |
Insulation material, | CFC/silicone-free | CFC/silicone-free | CFC/halogen/silicone-free |
Oil resistance | EN 60811‑2‑1 | EN 60811‑2‑1 | EN 60811‑2‑1 |
Outer jacket | PVC | PVC | PUR, HD22.10 S2 (VDE 0282, Part 10) |
Gray RAL 7032 | DESINA color green RAL 6018 | DESINA color green RAL 6018 | |
Flame-retardant | EN 60332‑1‑1 to 1‑3 | EN 60332‑1‑1 to 1‑3 | EN 60332‑1‑1 to 1‑3 |
1) The File No. is printed on the cable jacket.
Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.
Signal cables | MOTION‑CONNECT 500 | MOTION‑CONNECT 800PLUS |
---|---|---|
| 6FX500.‑....‑.... | 6FX800.‑.....‑.... |
Approvals, according to | ||
| UL758-CSA-C22.2-N.210.2-M90 | UL758-CSA-C22.2-N.210.2-M90 |
| Yes | Yes |
| Yes | Yes |
Rated voltage according to EN 50395 | 30 V | 30 V |
Test voltage, rms | 500 V | 500 V |
Operating temperature on the surface | ||
| -20 … +80 °C (‑4 ... +176 °F) | -50 … +80 °C (‑58 ... +176 °F) |
| 0 … 60 °C (+32 ... +140 °F) | -20 … +60 °C (‑4 ... +140 °F) |
Tensile stress, max. | ||
| 50 N/mm2 (7252 lbf/in2) | 50 N/mm2 (7252 lbf/in2) |
| 20 N/mm2 (2901 lbf/in2) | 20 N/mm2 (2901 lbf/in2) |
Smallest bending radius | ||
| 60 mm (2.36 in) | 4 x Dmax |
| 100 mm (3.94 in) | 70 mm (2.76 in) |
Torsional stress | Absolute 30°/m | Absolute 30°/m |
Bending | 2 million | 10 million |
Traversing velocity | 180 m/min (591 ft/min) | Up to 300 m/min (984 ft/min) |
Acceleration | 5 m/s2 (16.41 ft/s2) | Up to 50 m/s2 (164 ft/s2) |
Insulation material, incl. jacket | CFC/silicone-free | CFC/halogen/silicone-free |
Oil resistance | EN 60811‑2‑1 (mineral oil only) | EN 60811‑2‑1 |
Outer jacket | PVC | PUR, HD22.10 S2 (VDE 0282, Part 10) |
DESINA color green RAL 6018 | DESINA color green RAL 6018 | |
Flame-retardant | EN 60332‑1‑1 to 1‑3 | EN 60332‑1‑1 to 1‑3 |
1) The File No. is printed on the cable jacket.
Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.