Signal cables for SINUMERIK Siemens

Область применения



DRIVE‑CLiQ signal cables

DRIVE-CLiQ signal cables are used to connect components with DRIVE-CLiQ connections which have a separate or external 24 V DC power supply.

MOTION‑CONNECT DRIVE‑CLiQ signal cables

MOTION‑CONNECT DRIVE‑CLiQ signal cables with 24 V DC cores are used whenever components with DRIVE-CLiQ connections must meet high requirements such as mechanical stress and oil resistance, e.g. where a connection is made outside the cabinet between Power Modules/Motor Modules and SIMOTICS S-1FK7/SIMOTICS M-1PH8 motors with DRIVE-CLiQ interface.

MOTION-CONNECT pre-assembled signal cables

MOTION-CONNECT pre-assembled signal cables are used whenever motor encoders on motors without DRIVE-CLiQ interface are connected to Sensor Modules.

Обзор



MOTION‑CONNECT DRIVE‑CLiQ signal cable with IP20/IP67 connector

Signal cables are pre-assembled and are sold by the meter for the connection of a variety of components.

The following different types of cable are available:

  • DRIVE‑CLiQ signal cables
  • MOTION‑CONNECT DRIVE‑CLiQ signal cables
  • MOTION‑CONNECT pre-assembled signal cables

Дизайн



If pre-assembled signal cables are to be installed in a cable carrier in such a way that the connector would inhibit assembly, pre-assembled cables without assembled connector can also be supplied. In this case, the contacts of the cables are crimped and the connector enclosure is supplied separately. After installing the cables, the customer assembles the connector enclosure.

The 6FX.002‑2....‑.... signal cables are available with crimped contacts and with the connector enclosure supplied separately (not in the case of DRIVE‑CLiQ signal cables and signal cables with exposed core ends).

Signal cables with enclosed connector enclosure for the motor end. In this case, the 6th position of the Article No. must be changed from 0 to 4:
6FX.042‑2C...‑.... (not in the case of signal cables for connection via terminals or 6FX7002‑2SL01‑…., 6FX7002‑2SL02‑….).

Signal cables with enclosed connector enclosure for the module end. In this case, the 6th position of the Article No. must be changed from 0 to 1:
6FX.012‑2C...‑.... (not in the case of signal cables for connection via terminals or 6FX.002-2AH00-…., 6FX7002-2SL20-….).

Once the contacts have latched into the insulator, they can no longer be removed.

Type of delivery for pre-assembled signal cables

Pre-assembled signal cables are available in units of 10 cm (3.94 in).

The cables are supplied on reels up to 30 kg or 100 m (66.2 lb or 328 ft). Above 30 kg or 100 m (66.2 lb or 328 ft), cable drums are used instead of reels.

Технические данные



DRIVE‑CLiQ signal cables

DRIVE‑CLiQ

DRIVE‑CLiQ MOTION‑CONNECT 500

DRIVE‑CLiQ MOTION‑CONNECT 800PLUS

 

6FX2...‑1DC..‑....

6FX5...‑.DC..‑....

6FX8...‑.DC..‑....

Approvals, according to

   
  • cURus or UR/CSA

UL STYLE 2502/CSA-N.210.2-M90

UL STYLE 2502/CSA-N.210.2-M90

UL STYLE 20236/CSA-N.210.2-M90

  • UR-CSA File No.1)

Yes

Yes

Yes

  • RoHS conformity

Yes

Yes

Yes

Rated voltage according to EN 50395

30 V

30 V

30 V

Test voltage, rms

500 V

500 V

500 V

Operating temperature on the surface

   
  • Fixed installation

‑20 … +80 °C (‑4 ... +176 °F)

‑20 … +80 °C (‑4 ... +176 °F)

‑20 … +80 °C (‑58 ... +176 °F)

  • Flexible installation

0 … 60 °C (+32 ... +140 °F)

‑20 … +60 °C (‑4 ... +140 °F)

Tensile stress, max.

   
  • Fixed installation

45 N/mm2 (6526 lbf/in2)

80 N/mm2 (11603 lbf/in2)

50 N/mm2 (7252 lbf/in2)

  • Flexible installation

30 N/mm2 (4351 lbf/in2)

20 N/mm2 (2901 lbf/in2)

Smallest bending radius

   
  • Fixed installation

50 mm (1.97 in)

35 mm (1.38 in)

35 mm (1.38 in)

  • Flexible installation

125 mm (4.92 in)

75 mm (2.95 in)

Torsional stress

Absolute 30°/m

Absolute 30°/m

Bending

100000

10 million

Traversing velocity

30 m/min (98.4 ft/min)

300 m/min (984 ft/min)

Acceleration

2 m/s2 (6.56 ft/s2)

Up to 50 m/s2 (164 ft/s2)
see charasteristic curves under "MOTION‑CONNECT connection systems"

Insulation material,
incl. jacket

CFC/silicone-free

CFC/silicone-free

CFC/halogen/silicone-free
IEC 60754‑1/DIN VDE 0472‑815

Oil resistance

EN 60811‑2‑1

EN 60811‑2‑1
(mineral oil only)

EN 60811‑2‑1

Outer jacket

PVC

PVC

PUR, HD22.10 S2 (VDE 0282, Part 10)

 

Gray RAL 7032

DESINA color green RAL 6018

DESINA color green RAL 6018

Flame-retardant

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3



1) The File No. is printed on the cable jacket.

Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.

Signal cables

MOTION‑CONNECT 500

MOTION‑CONNECT 800PLUS

 

6FX500.‑....‑....

6FX800.‑.....‑....

Approvals, according to

  
  • cURus or UR/CSA

UL758-CSA-C22.2-N.210.2-M90

UL758-CSA-C22.2-N.210.2-M90

  • UR-CSA File No.1)

Yes

Yes

  • RoHS conformity

Yes

Yes

Rated voltage according to EN 50395

30 V

30 V

Test voltage, rms

500 V

500 V

Operating temperature on the surface

  
  • Fixed installation

-20 … +80 °C (‑4 ... +176 °F)

-50 … +80 °C (‑58 ... +176 °F)

  • Flexible installation

0 … 60 °C (+32 ... +140 °F)

-20 … +60 °C (‑4 ... +140 °F)

Tensile stress, max.

  
  • Fixed installation

50 N/mm2 (7252 lbf/in2)

50 N/mm2 (7252 lbf/in2)

  • Flexible installation

20 N/mm2 (2901 lbf/in2)

20 N/mm2 (2901 lbf/in2)

Smallest bending radius

  
  • Fixed installation

60 mm (2.36 in)

4 x Dmax

  • Flexible installation

100 mm (3.94 in)

70 mm (2.76 in)

Torsional stress

Absolute 30°/m

Absolute 30°/m

Bending

2 million

10 million

Traversing velocity

180 m/min (591 ft/min)

Up to 300 m/min (984 ft/min)

Acceleration

5 m/s2 (16.41 ft/s2)

Up to 50 m/s2 (164 ft/s2)
see charasteristic curves under "MOTION‑CONNECT connection systems"

Insulation material, incl. jacket

CFC/silicone-free

CFC/halogen/silicone-free
IEC 60754‑1/DIN VDE 0472‑815

Oil resistance

EN 60811‑2‑1 (mineral oil only)

EN 60811‑2‑1

Outer jacket

PVC

PUR, HD22.10 S2 (VDE 0282, Part 10)

 

DESINA color green RAL 6018

DESINA color green RAL 6018

Flame-retardant

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3



1) The File No. is printed on the cable jacket.

Degree of protection of pre-assembled signal cables and their extensions when closed and connected: IP67.