Power cables for SINAMICS S120 Siemens

Обзор



Power cable for connecting a SIMOTICS M‑1PH8 motor with terminal box to a SINAMICS S120 Motor Module

Power cable with supplied connector for connecting a SIMOTICS S‑1FT7/‑1FK7/ SIMOTICS M‑1PH8 motor to a SINAMICS S120 Motor Module

The synchronous and asynchronous motors are connected to the Motor Modules or Power Modules by means of MOTION‑CONNECT power cables.

The pre-assembled MOTION‑CONNECT power cables are of high quality and offer safety with problem-free functioning.

Depending on the design, the MOTION‑CONNECT power cables are either pre-assembled at one end or at both ends.

If pre-assembled power cables are to be installed in a cable carrier in such a way that the connector would inhibit assembly, pre-assembled cables without assembled connector can also be supplied. In this case, the contacts of the cables are crimped and the connector enclosure is supplied separately. After installing the cables, the customer assembles the connector enclosure.

The 6FX.002‑5.... power cables are available with crimped contacts and with the connector enclosure supplied separately (not in the case of power cables with exposed core ends or cable lugs).

Power cables with separately supplied motor-end connector enclosure. In this case, the 6th position of the Article No. must be changed from 0 to 4: 6FX.042‑5...‑.... (not in the case of power cables with exposed core ends on the motor end).

Power cables with separately supplied module-end connector enclosure. In this case, the 6th position of the Article No. must be changed from 0 to 1: 6FX.012‑5....‑.... (not in the case of power cables for SINAMICS S120 Power Modules or booksize compact).

Type of delivery of pre-assembled power cables

Pre-assembled power cables can be ordered in length units of 10 cm (3.94 in) up to a maximum length of 299 m (984 ft).

The cables are supplied on reels up to 30 kg or 100 m (66.2 lb or 328 ft). Above 30 kg or 100 m (66.2 lb or 328 ft), cable drums are used instead of reels. This applies to both pre-assembled power cables and for cables sold by the meter.

Type of delivery of power cables sold by the meter

Fixed lengths

Cross-section

Brake cores

MOTION‑CONNECT 500
MOTION‑CONNECT 800PLUS

1.5 mm2

with/without

50 m (164 ft), 100 m (328 ft),
200 m (656 ft), 500 m (1641 ft)

2.5 mm2

with/without

50 m (164 ft), 100 m (328 ft),
200 m (656 ft), 500 m (1641 ft)



Variable length, available in exact meter lengths

Cross-section

Brake cores

MOTION‑CONNECT 500

MOTION‑CONNECT 800PLUS

4 mm2

with/without

≤ 500 m (1641 ft)

≤ 500 m (1641 ft)

6 mm2

with/without

≤ 500 m (1641 ft)

≤ 500 m (1641 ft)

10 mm2

with/without

≤ 500 m (1641 ft)

≤ 500 m (1641 ft)

16 mm2

with/without

≤ 200 m (656 ft)

≤ 200 m (656 ft)

25 mm2

without

≤ 200 m (656 ft)

 

with

≤ 200 m (656 ft)

≤ 200 m (656 ft)

35 mm2

without

≤ 200 m (656 ft)

 

with

≤ 200 m (656 ft)

≤ 200 m (656 ft)

50 mm2

without

≤ 200 m (656 ft)

 

with

≤ 200 m (656 ft)

≤ 200 m (656 ft)

70 mm2

without

≤ 100 m (328 ft)

95 mm2

without

≤ 100 m (328 ft)

120 mm2

without

≤ 100 m (328 ft)



Характеристика



Characteristic curves for MOTION‑CONNECT 800PLUS

The blue area beneath the characteristic curve represents the potential range of use for the cables. The characteristic curves represent the tested operating points.

Permissible acceleration for signal and power cables MOTION‑CONNECT 800PLUS up to 16 mm2

Permissible acceleration for power cables MOTION‑CONNECT 800PLUS with 25 mm2, 35 mm2 and 50 mm2

Технические данные



Power cables

MOTION‑CONNECT 500

MOTION‑CONNECT 800PLUS

 

6FX500.‑....‑....

6FX800.‑.....‑....

Approvals, according to

  
  • VDE1)

Yes

Yes

  • cURus or UR/CSA

UL 758, CSA‑C22.2‑N.210.2‑M90

UL 758, CSA‑C22.2‑N.210.2‑M90

  • UR-CSA File No.2)

Yes

Yes

  • RoHS conformity

Yes

Yes

Rated voltage V0/V in accordance with EN 50395

  
  • Power conductors

600 V/1000 V

600 V/1000 V

  • Signal conductors

24 V (EN) 1000 V (UL/CSA)

24 V (EN) 1000 V (UL/CSA)

Test voltage, rms

  
  • Power conductors

4 kV

4 kV

  • Signal conductors

2 kV

2 kV

Operating temperature on the surface

  
  • Fixed installation

‑20 … +80 °C (‑4 ... +176 °F)

‑50 … +80 °C (‑58 ... +176 °F)

  • Flexible installation

0 … 60 °C (32 ... 140 °F)

‑20 … +60 °C (‑4 ... +140 °F)

Tensile stress, max.

  
  • Fixed installation

50 N/mm2 (7252 lbf/in2)

50 N/mm2 (7252 lbf/in2)

  • Flexible installation

20 N/mm2 (2901 lbf/in2)

20 N/mm2 (2901 lbf/in2)

Smallest bending radius

  
  • Fixed installation

5 × Dmax

4 × Dmax

  • Flexible installation

See selection and ordering data

See selection and ordering data

Torsional stress

Absolute 30°/m

Absolute 30°/m

Bending

100000

10 million

Traversing velocity

30 m/min (98.4 ft/min)

Up to 300 m/min (984 ft/min)

Acceleration

2 m/s2 (6.56 ft/s2)

Up to 50 m/s2 (164 ft/s2)
see characteristic curves

Insulation material, incl. jacket

CFC/silicone-free

CFC/halogen/silicone-free
IEC 60754‑1/DIN VDE 0472‑815

Oil resistance

EN 60811‑2‑1
(nur Mineralöl)

EN 60811‑2‑1

Outer jacket

PVC

PUR, HD22.10 S2 (VDE 0282, Part 10)

 

DESINA color orange RAL 2003

DESINA color orange RAL 2003

Flame-retardant

EN 60332‑1‑1 to 1‑3

EN 60332‑1‑1 to 1‑3



Degree of protection of the pre-assembled power cables and their extensions when closed and connected: IP67.

1) The respective registration number is printed on the cable jacket (only applies to power cables).

2) The File No. is printed on the cable jacket.