1PH8 for SINAMICS S120 for cranes Siemens
Обзор
1PH8 three‑phase motor, shaft height 355
The innovations in the field of modern crane installations place higher and higher demands on compact asynchronous motors.
The compact asynchronous motor 1PH8 of shaft height 355 covers the increased performance requirements, e.g. for intermittent duty S3‑40 % with up to 1.97 MW.
This motor serie is a converter solution which has been developed for use in conjunction with the SINAMICS S120 drive system. The 1PH8 asynchronous motors have the following features:
- Forced ventilated asynchronous motors with squirrel‑cage rotor with IP55 degree of protection. The motors are ventilated as standard by a radial, externally mounted fan unit. With the "enhanced corrosion protection" option, the motors can also be installed outdoors.
- Forced ventilated asynchronous motors with squirrel‑cage rotor with IP23 degree of protection. These motors are also ventilated as standard by a radial, externally mounted fan unit. These motors are particularly suitable for installation in power houses.
Особенности
- High power density with small motor dimensions
- Wide speed control ranges
- Speed down to zero without reducing the torque (constant torque characteristic)
- High rotational accuracy, even at the lowest speeds
- Fitted as standard with regreasing unit and insulated NDE bearing
- Optimized for converter‑fed operation on SINAMICS
- Large selection of options
Технические данные
Insulation of the stator winding | Utilization to temperature class 155 (F) |
Cooling | Radial fan NDE top mounted |
Temperature monitoring | KTY 84 temperature sensor in the stator winding |
Motor supply voltage (for technical data, see the ventilation data and sound pressure level) | 400 V 3 AC, 50/60 Hz |
Type of construction | IM B3 |
Degree of protection | IP23 or IP55 |
Shaft extension on the drive end | Feather key |
Shaft and flange accuracy | Tolerance N (normal) |
Vibration severity | Level A (normal) |
Sound pressure level Tolerance +3 dB | Sound pressure level 85 dB(A) |
Maximum speeds | 2800 rpm |
External encoder systems | Incremental encoder HTL 1024 S/R POG 10 (Baumer‑Hübner) |
Connection | Terminal box NDE right or DE top |
Paint finish | Standard paint finish, anthracite, RAL 7016 |
Options | Refer to Options and Selection and ordering data |
1) Rotational accuracy of shaft extension, concentricity of spigot and shaft and perpendicularity of mounting face of flange to shaft.
S/R = signals/revolution
Notes:
The rated motor data is specified in the selection and ordering data for a nominal pulse frequency of 2.5 kHz.
Ventilation data and sound pressure level
Motor version (see 8th and 11th positions | Fan motor: | Direction of air‑flow | Sound pressure level LpA (1 m) | Volume of air | ||
Current consumption at | ||||||
400 V/50 Hz | 400 V/60 Hz | 460 V/60 Hz | ||||
| A | A | A |
| dB | m3/s |
1PH8 motors, shaft height 355 | ||||||
1PH835.-7..1 (asynchronous version, | 8.2 | 7.9 | 7.9 | NDE → DE | 85 | 1 |
1PH835.-7..4 (asynchronous version, | 8.2 | 13.21) | 10.92) | NDE → DE | 85 | 1.3 |
1) Special fan for operation at 460 V/60 Hz (± 10 %), option: R60 (see Selection and ordering data/Order No. supplements).
2) Special fan for operation at 400 V/60 Hz (± 10 %), option: R61 (see Selection and ordering data/Order No. supplements).
Important note:
For 1PH8/SH 355/IP23/85 dB(A) motors, a special fan motor must be ordered using option R60/R61 for operating the external fan on a supply voltage of 60 Hz (see Selection and ordering data/Order No. supplements).
Terminal box, max. connectable conductor cross sections
Terminal box type (see selection and | Cable entry | Cable entry | Outer cable diameter, max.1) | Number of | Cross section, max. | Current, max. |
|
|
| mm |
| mm2 | A |
1PH8 motors, shaft height 355 | ||||||
1XB7712-P013) | 3 × M63 × 1.5 | 1 × M20 × 1.5 4) | 53 | Phases: 3 × 4 M16 | 3 × 95 | 450 |
1XB7712-P033) | 4 × M75 × 1.5 | 1 × M20 × 1.5 4) | 68 | Phases: 3 × 4 M16 | 4 × 185 | 1150 |
1XB7820-P00 | Not drilled | 1 × M20 × 1.5 4) | – | Phases: 2 × 3 × 4 M16 | 8 × 240 | 2100 |
1) Dependent on the design of the metric cable gland.
2) Current carrying capacity based on IEC 60364‑5‑52, routing type C.
3) For terminal box type 1XB7712-P.., depending on the standard, other cable entries (power) can be ordered using P options (see Selection andordering data/Order No. supplements).
4) Mounted on left side of terminal box (viewed towards cable entries).
5) Mounted on right side of terminal box (viewed toward cable entries).