PM 1507, 24 В DC/8 A Siemens
Область применения
Дизайн и функциональность 1-фазного блока питания SIMATIC PM 1507 с автоматическим переключением входного диапазона оптимально подходит для использования с контроллером SIMATIC S7-1500 PLC. Этот блок питает системные компоненты S7-1500, такие как, CPU, система питания (PS), входные и выходные цепи модулей ввода-вывода и если требуется, то и датчики и исполнительные механизмы на 24В
Технические данные
Order No. | 6EP1 333-4BA00 |
Product | S7-1500 PM1507 |
Power supply, type | 24 V/8 A |
Input |
|
Input | 1-phase AC |
Rated voltage Uin rated min. |
|
Supply voltage |
|
|
|
|
|
Rated voltage Uin rated max. |
|
Supply voltage |
|
|
|
|
|
| 120 V |
| 230 V |
| … |
| Automatic range selection |
Voltage range | … |
Input voltage |
|
| 85 … 132 V |
| 170 … 264 V |
| … |
Overvoltage strength | 2.3 x Uin rated, 1.3 ms |
Mains buffering at lout rated, min. | 20 ms |
Mains buffering | at Uin = 93/187 V |
Rated line frequency |
|
| 50 Hz |
| 60 Hz |
Line frequency range | 45 … 65 Hz |
Input current |
|
| 3.7 A |
| 1.7 A |
|
|
|
|
|
|
Switch-on current limitation (+ 25 °C), max. | 62 A |
I²t, max. | 12 A²·s |
Built-in input fuse | T 6.3 A/250 V (not accessible) |
Protection in the supply feeder (IEC 898) | Recommended miniature circuit breaker: 16 A, characteristic B or 10 A, characteristic C |
Output |
|
Output | Controlled, isolated DC voltage |
Rated voltage Uout rated DC | 24 V |
Total tolerance, static ± | 1 % |
Static mains compensation, approx. | 0.1 % |
Static load compensation, approx. | 0.1 % |
Residual ripple, peak-peak, max. | 50 mV |
Residual ripple, peak-peak, typ. |
|
Spikes peak-peak, max. (bandwidth approx. 20 MHz) | 150 mV |
Spikes peak-peak, typ. (bandwidth approx. 20 MHz) |
|
Adjustment range | … |
Product function: output voltage is adjustable | No |
Setting the output voltage |
|
Note |
|
Status display | LED green for 24 V O.K.; LED red for fault; LED yellow for stand-by |
Signaling |
|
On/off behavior | No overshoot of Uout (soft start) |
Startup delay, max. | 1.5 s |
Note |
|
Voltage rise, typ. | 10 ms |
Maximum voltage rise time of the output voltage |
|
Rated current Iout rated | 8 A |
Current range | 0 … 8 A |
Note |
|
typical active power output | 192 W |
short-term overload current in the event of a short circuit during startup, typical | 35 A |
Duration of the overload capability overcurrent in the event of a short circuit during startup | 70 ms |
constant overload current in the event of a short circuit during startup, typical |
|
short-term overload current in the event of a short circuit during operation, typical | 35 A |
Duration of the overload capability overcurrent in the event of a short circuit during operation | 70 ms |
constant overload current in the event of a short circuit during operation, typical |
|
Parallel switching for enhanced performance | Yes |
Note | Parallel connection of 3 A and 8 A possible; devices must be activated simultaneously, at I load max. 75 % per device |
Number of devices that can be switched in parallel to increase performance, units | 2 |
Efficiency |
|
Efficiency at Uout rated, lout rated, approx. | 90 % |
Power loss at Uout rated, lout rated, approx. | 21 W |
Closed-loop control |
|
Dynamic mains compensation (Uin rated ± 15 %), max. | 0.1 % |
Dynamic load compensation (Iout: 50/100/50 %), Uout ± typ. | 2 % |
Load-step setting time 50 to 100 %, typ. |
|
Load-step setting time 100 to 50 %, typ. |
|
Setting time, maximum | 5 ms |
Protection and monitoring |
|
Output overvoltage protection | additional control loop, differentiation (closed-loop control) at < 28.8 V |
Response value current limitation |
|
| 8.4 A |
| 9.6 A |
Current limitation, typ. | 9 A |
Property of the output, short-circuit-proof | Yes |
Short-circuit protection | Electronic shutdown, automatic restart |
Sustained short-circuit current rms value, typical |
|
Note |
|
Overload/short-circuit indicator | - |
Security |
|
Primary/secondary isolation | Yes |
Electrical isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 and EN 61131-2 |
Protection class | Class I |
Leakage current |
|
| 3.5 mA |
| 1.3 mA |
CE marking | Yes |
UL/CSA approval |
|
UL/cUL (CSA) approval | Available soon |
Explosion protection | Available soon |
FM approval |
|
FM approval |
|
CB approval | Yes |
Marine approval |
|
Degree of protection (EN 60529) | IP20 |
EMC |
|
Emitted interference | EN 55022 Class B |
Supply harmonics limitation | EN 61000-3-2 |
Noise immunity | EN 61000-6-2 |
Operating data |
|
Ambient temperature |
|
| 0 … 60 °C |
| with natural convection |
Ambient temperature |
|
| -40 … +85 °C |
| -40 … +85 °C |
Humidity class according to EN 60721 | Climate class 3K3, without condensation |
Mechanical system |
|
Connections | Screw/spring-type connection technology |
Connections |
|
| L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² |
| L+, M: 2 screw terminals each for 0.5 ... 2.5 mm² |
|
|
Width of enclosure | 75 mm |
Height of enclosure | 147 mm |
Depth of enclosure | 129 mm |
Mounting width | 75 mm |
Mounting height | 205 mm |
Weight, approx. | 0.74 kg |
Product property of the enclosure: side-by-side enclosure | Yes |
Type of mounting |
|
| No |
| No |
| No |
Installation | can be mounted onto S7-1500 rail |
electrical accessories |
|
mechanical accessories |
|