SIPLUS S7-400 CP 443-1 Advanced Siemens

Область применения
The CP 443-1 Advanced is used to connect the SIMATIC S7-400 to Industrial Ethernet networks. With its own processor, it relieves the CPU of communication tasks and facilitates additional connections.
The CP 443-1 Advanced provides the following communication options:
- PGs/PCs
- Master computers
- HMI systems
- SIMATIC S5/S7/C7 systems
- PROFINET I/O devices
- PROFINET CBA components
All the devices of an Ethernet network can be protected from unauthorized access. The CP 443-1 Advanced allows safe remote access over the Internet and allows data transfer between devices or network segments to be protected from data manipulation/espionage.
PROFINET CBA components and security functionalities can be used as an alternative.
Secure VPN communication between SCALANCE S, SOFTNET Security Client and components with Security Integrated
Обзор
- Connection of SIMATIC S7-400 to Industrial Ethernet
- Multi-protocol operation for ISO, TCP/IP, UDP and PROFINET IO protocols
- Adjustable keep-alive function
- Two separate interfaces (integrated network separation):
- Gigabit interface with one RJ45 port with 10/100/1 000 Mbit/s, full/half-duplex with auto-sensing capability
- PROFINET interface with four RJ45 ports with 10/100 Mbit/s, full/half duplex with autosensing and autocrossover functionality via integrated 4-port switch
- Communications services via both interfaces
- Open communication (ISO, TCP/IP and UDP), multicast with UDP, including routing between both interfaces
- PG/OP communication:
Cross-network by means of S7 routing - S7 communication (client, server, multiplexing) including routing between both interfaces
- IT communication:
HTTP communication supports access to process data via own Web pages;
e-mail client function, sending of e-mails with authentication directly from user program;
FTP communication supports program-controlled FTP client communication;
access to data blocks through FTP server
- Communications services via PROFINET interface
- PROFINET IO controller with real-time properties (RT and IRT)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or via the user program (e.g. HMI)
- Support of the prioritized startup of PROFINET IO devices
- Configuration with STEP 7
- Media redundancy (MRP);
the CP supports the media redundancy procedure MRP within an Ethernet network with ring topology. - Access protection by means of configurable IP access list
- Module replacement without programming device;
all information is stored on the C-PLUG (also file system for IT functions) - Extensive diagnostic functions for all modules in the rack
- Integration into network management systems through the support of SNMP V1 MIB-II
- Operation in the SIMATIC H system for redundant S7-communication
- Operation in fail-safe applications (PROFIsafe) in combination with SIMATIC S7-400 CPU 416F
Note:
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added.
SIPLUS CP 443-1 Advanced | |
Article No. | 6AG1443-1GX30-4XE0 |
Order number based on | 6GK7443-1GX30-0XE0 |
Ambient temperature range | 0 ... +60 °C |
Conformal coating | Coating of the printed circuit boards and the electronic components |
Technical data | The technical data of the standard product applies, except for the ambient conditions |
Ambient conditions | |
Relative humidity | 100%, condensation/frost permitted. No commissioning in bedewed state. |
Biologically active substances, compliance with EN 60721-3-3 | Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation! |
Chemically active substances, compliance with EN 60721-3-3 | Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation! |
Mechanically active substances, compliance with EN 60721-3-3 | Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation! |
Air pressure (depending on the highest positive temperature range specified) | 1 080 ... 795 hPa (-1 000 ... +2 000 m) 795 ... 658 hPa (+2 000 ... +3 500 m) 658 ... 540 hPa (+3 500 ... +5 000 m) |
Technical documentation on SIPLUS can be found here:
http://www.siemens.de/siplus-extreme
Дизайн
The CP 443-1 Advanced offers all the advantages of SIMATIC S7-400 system design:
- Compact design:
- Five RJ45 jacks for connecting to Industrial Ethernet via two independent interfaces; one of which is a security socket for externally safeguarding the network cell; automatic data rate detection by means of the autosensing and autocross function; the connection is made via the IE FC RJ45 Plug 180 with 180° cable outlet or via a standard patch cable
- Diagnostics LEDs for indicating the operational and communication status
- Simple installation;
the CP 443-1 Advanced is mounted on the S7-400 rack and connected to other modules by means of the backplane bus. There are no slot rules. - The CP 443-1 Advanced can be operated without a fan.
- In combination with IM 460/461, the CP 443-1 Advanced can also be used in an expansion rack (ER).
- The module can be replaced without the need for a programming device
- C-PLUG (configuration plug) is included in scope of delivery as a swap medium (cannot be operated without C-PLUG).
Функции
- Two separate interfaces (integrated network separation):
- Gigabit interface with one RJ45 port with 10/100/1 000 Mbps, full/half-duplex with auto-sensing capability
- PROFINET interface with four RJ45 ports with 10/100 Mbps full/half duplex with autosensing and autocrossover functionality via integrated 4-port switch
- Communication services via both interfaces:
- Open communication (TCP/IP and UDP):
Multicast with UDP, including routing between both interfaces - PG/OP communication: Inter-network with S7 routing
- S7 communication (client, server, multiplexing) including routing between both interfaces
- S7 H communication for S7-400 H systems, now also across network boundaries (ISO-on-TCP)
- IT communication:
HTTP communication permits access to process data via user''s own Web pages. HTTPS communication is also possible with the CP 443-1 Advanced1).
The e-mail client function allows e-mails to be sent directly from the user program.
FTP communication allows program-controlled FTP client communication.
Access to data blocks via FTP server.
- Open communication (TCP/IP and UDP):
- Communication services via PROFINET interfaces:
- Certified PROFINET IO controller with real-time properties (RT and IRT)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or via user program (e.g. for HMI)
- Media redundancy (MRP):
- Within an Ethernet network with a ring topology, the CP supports the MRP media redundancy protocol as an MRP manager and as an MRP client
- Diagnostics and network management:
- Comprehensive diagnostics functions for all modules in the rack (including graphical diagnostics, e.g. topology)
- Integration in network management systems due to support of SNMP V1/V3
- Security mechanisms:
- Access protection by means of configurable IP access list
- Firewall for filtering connections on the basis of their IP/port addresses
- Bandwidth limitation to avoid communication overload
- VPN server and VPN client for tap-proof access to controllers
- Encrypted HTML pages using SSL (HTTPs)
- Secure file transfer (FTPs)
- Tap-proof transfer of network analysis information to the network management system (SNMP)
- Translation of private and public IP addresses (NAT/NAPT)
- Secure transfer of the time of day (NTP V3)
- Secure firmware update
- Plagiarism detection
- Certification as per the Achilles Level II Standard
http://www.wurldtech.com/product_services/certifications/certified_products/
- Configuration of all functions with STEP 7;
The security functions are configured using the Security Configuration Tool (SCT) included in the scope of delivery for STEP 7 V5.5 SP2 HF1. - Configuration with STEP 7 Professional V11;
only possible with a limited range of functions of the predecessor CP 443-1 (6GK7 443-1GX20-0XE0), without security functions and CBA.
Version with security functions for TIA Portal in the planning stages. - When using the blocks AG_SSEND (FC53), AG_SRECV (FC63), TSEND (FB63), TRCV (FB64), TCON (FB65) and TDISCON (FB66), please note the following information: http://support.automation.siemens.com/WW/view/en/60037071
- Module replacement without programming device:
All information is stored on the C-PLUG (as well as file system for IT functions)
Интеграция
Connection to higher-level network
Small independent local networks (e.g. within a machine or cell)
Особенности
- Cost advantage due to connection to two separate Ethernet segments with integrated network separation
- High plant availability through the support of media redundancy (MRP) and use in the SIMATIC S7-400 H system
- Optimum support of maintenance through
- Web-based diagnostics
- Remote programming via WAN or telephone network (ISDN)
- Monitoring with IT network management tools (SNMP)
- Module replacement without programming device using the C-PLUG swap medium
- Securing the system against unauthorized access by means of
- Central access protection for any devices within an automation cell, e.g. by means of authentication of the network stations
- Secure remote access via the Internet by means of data encryption (VPN) and data integrity checking
- Traceability by means of data logging on the basis of standard IT mechanisms (Syslog)
- Later connection of existing SIMATIC S7 systems to Industrial Ethernet using the CP 443-1 Advanced ensures investment protection
Технические данные
Order number | 6GK7443-1GX30-0XE0 | |
---|---|---|
Product type designation | CP 443-1 Advanced | |
Transmission rate |
| |
Transfer rate |
| |
| 10 ... 1 000 Mbit/s | |
| 10 ... 100 Mbit/s | |
Interfaces |
| |
Number of interfaces acc. to Industrial Ethernet | 5 | |
Number of electrical connections |
| |
| 1 | |
| 4 | |
Type of electrical connection |
| |
| RJ45 port | |
| RJ45 port | |
design of the removable storage C-PLUG | Yes | |
Supply voltage, current consumption, power loss |
| |
Type of voltage of the supply voltage | DC | |
Supply voltage 1 from backplane bus | 5 V | |
Relative symmetrical tolerance for DC |
| |
| 5 % | |
Consumed current |
| |
| 1.8 A | |
Active power loss | 9 W | |
Permitted ambient conditions |
| |
Ambient temperature |
| |
| 0 ... 60 °C | |
| -40 ... +70 °C | |
| -40 ... +70 °C | |
Relative humidity at 25 °C without condensation during operation maximum | 95 % | |
Protection class IP | IP20 | |
Design, dimensions and weight |
| |
Module format | Compact module S7-400 single width | |
Width | 25 mm | |
Height | 290 mm | |
Depth | 210 mm | |
Net weight | 0.7 kg | |
Product properties, functions, components general |
| |
Number of units |
| |
| 14 | |
| max. 4 as PN IO ctrl. | |
Performance data open communication |
| |
Number of possible connections for open communication by means of SEND/RECEIVE blocks |
| |
| 64 | |
Amount of data |
| |
| 8 Kibyte | |
| 8 Kibyte | |
| 8 Kibyte | |
| 2 Kibyte | |
Number of possible connections for open communication |
| |
| 64 | |
Amount of data |
| |
| 1 452 byte | |
Performance data S7 communication |
| |
Number of possible connections for S7 communication |
| |
| 128 | |
| 2 | |
| when using several CPUs | |
Performance data multi-protocol mode |
| |
Number of active connections with multi-protocol mode | 128 | |
Performance data IT functions |
| |
Number of possible connections |
| |
| 20 | |
| 10 | |
| 4 | |
| 1 | |
Amount of data as user data for email maximum | 8 Kibyte | |
Storage capacity of the user memory |
| |
| 30 Mibyte | |
| 16 Mibyte | |
| 512 Kibyte | |
Number of possible write cycles of the flash memory cells | 100 000 | |
Performance data PROFINET communication as PN IO-Controller |
| |
Product function PROFINET IO controller | Yes | |
Number of PN IO devices on PROFINET IO controller usable total | 128 | |
Number of PN IO IRT devices on PROFINET IO controller usable | 64 | |
Number of external PN IO lines with PROFINET per rack | 4 | |
Amount of data |
| |
| 8 Kibyte | |
| 8 Kibyte | |
| 1 433 byte | |
| 1 433 byte | |
| 240 byte | |
| 240 byte | |
Performance data PROFINET CBA |
| |
Number of remote connection partners with PROFINET CBA | 64 | |
Number of connections with PROFINET CBA total | 600 | |
Amount of data |
| |
| 8 Kibyte | |
| 8 Kibyte | |
| 8 Kibyte | |
| 250 byte | |
| 2 400 byte | |
Performance data PROFINET CBA remote connection with acyclic transmission |
| |
Refresh time of the remote interconnections in the case of acyclic transmission with PROFINET CBA | 100 ms | |
Number of remote connections to input variables in the case of acyclic transmission with PROFINET CBA maximum | 150 | |
Number of remote connections to output variables in the case of acyclic transmission with PROFINET CBA maximum | 150 | |
Amount of data |
| |
| 8 Kibyte | |
| 8 Kibyte | |
Performance data PROFINET CBA remote connection with cyclic transmission |
| |
Refresh time of the remote interconnections with PROFINET CBA with cyclical transfer | 10 ms | |
Number of remote connections to input variables with PROFINET CBA with cyclical transfer maximum | 250 | |
Number of remote connections to output variables with PROFINET CBA with cyclical transfer maximum | 250 | |
Amount of data |
| |
| 2 000 byte | |
| 2 000 byte | |
Performance data PROFINET CBA HMI variables via PROFINET acyclic |
| |
Number of connectable HMI stations for HMI variables in the case of acyclic transmission with PROFINET CBA | 3 | |
Refresh time of the HMI variables in the case of acyclic transmission with PROFINET CBA | 500 ms | |
Number of HMI variables in the case of acyclic transmission with PROFINET CBA maximum | 200 | |
Amount of data as user data for HMI variables in the case of acyclic transmission with PROFINET CBA maximum | 8 Kibyte | |
Performance data PROFINET CBA device-internal connections |
| |
Number of internal connections with PROFINET CBA maximum | 300 | |
Amount of data of the internal connections with PROFINET CBA maximum | 2 400 byte | |
Performance data PROFINET CBA connections to constants |
| |
Number of connections with constants with PROFINET CBA maximum | 500 | |
Amount of data as user data for interconnections with constants with PROFINET CBA maximum | 4 000 byte | |
Performance data PROFINET CBA PROFIBUS proxy functionality |
| |
Product function with PROFINET CBA PROFIBUS proxy functionality | No | |
Performance data telecontrol |
| |
Protocol is supported |
| |
| Yes | |
Product functions management, configuration |
| |
Product function MIB support | Yes | |
Protocol is supported |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
Configuration software |
| |
| STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher | |
| SIMATIC iMap V3.0 SP1 and higher | |
Product functions Diagnosis |
| |
Product function Web-based diagnostics | Yes | |
Product functions switch |
| |
Product feature Switch | Yes | |
Product function |
| |
| No | |
| Yes | |
| Yes | |
Product functions Redundancy |
| |
Product function |
| |
| Yes | |
| Yes | |
Protocol is supported Media Redundancy Protocol (MRP) | Yes | |
Product functions Security |
| |
Firewall version | stateful inspection | |
Product function with VPN connection | IPSec | |
Type of encryption algorithms with VPN connection | AES-256, AES-192, AES-128, 3DES-168, DES-56 | |
Type of authentication procedure with VPN connection | Preshared key (PSK), X.509v3 certificates | |
Type of hashing algorithms with VPN connection | MD5, SHA-1 | |
Number of possible connections with VPN connection | 32 | |
Product function |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| No | |
Product functions Time |
| |
Product function SICLOCK support | Yes | |
Product function pass on time synchronization | Yes | |
Protocol is supported NTP | Yes |