CPU 1507S Siemens

Область применения



The S7-1500 Software Controller CPU 1507S implements the function of a S7-1500 Controller as software on a SIMATIC IPC with Windows. The CPU 1507S is optimized for PC-based control tasks with the IPC427 Microbox PC and the IPC477D Panel PC. In addition, the CPU 1507S supports the IPC627D and IPC827D Box PCs, the IPC677D Panel PC and the IPC647D and IPC847D Rack PCs.

Обзор


  • Software Controller for implementing the functions of a SIMATIC S7-1500 Controller on a SIMATIC IPC
  • Optimized for PC-based control tasks with the IPC427 Microbox PC and the IPC477D Panel PC.
  • Can also be used on IPC627D and IPC827D Box PCs, IPC677D Panel PC, and IPC647D and IPC847D Rack PCs.

Дизайн



The CPU 1507S Software Controller has the following components:

  • Windows-independent control core:
    • Parallel operation of control and Windows by means of real-time Hypervisor technology
    • Windows restart while control is running
    • Windows-independent access to bulk memory (CFast, SSD, HDD) for independent storage of configuration and data
  • Screen application with functions for
    • display of overview information, such as IP address of the integrated interface, station name, plant designation, location identifier, etc.,
    • display of diagnostics information
    • display of module information
    • display of a user-definable logo
    • showing display settings
    • setting IP addresses
    • setting the date and time
    • selecting the operating mode
    • resetting the CPU to factory settings
    • disabling/enabling the display
    • enabling protection levels.
  • Integrated drivers for IO communication via Ethernet and PROFIBUS interfaces of the PC
  • Integrated driver for communication via Windows Ethernet interfaces
  • PC-internal communication with WinCC RT Advanced
  • PC-internal communication with Windows applications

Функции



The S7-1500 standard CPU - the CPU 1507S - implements the function of a S7-1500 Controller as software on a PC with Windows. This enables a PC to be used for controlling machines or plants.

  • Configuring and programming with the STEP 7 engineering tool in the TIA Portal (as from version 13 SP1):
  • Programmable according to IEC 61131-3
  • Programming languages supported:
    • SCL (IL)
    • LAD
    • FBD
    • STL
    • GRAPH7 (SFC)
  • Innovative real-time system based on virtualization technology;
    The real-time system of the integrated S7-1500 software controller enables parallel, independent operation of Windows:
    • Maximum real-time and deterministic properties
    • Operation independent of Windows – supports restart of Windows while the controller is in operation
    • Fast restart of the control independently of Windows
  • High-speed program execution with several priority-controlled execution levels (cyclic, time-controlled, isochronous with PROFINET or PROFIBUS, event-driven via process and diagnostics alarms)
  • Saving of retentive data;
    The software controller ensures the security of plant data even when the power fails:
    • Storage of retentive data on PC hard disk (UPS required)
    • Saving of retentive data on the NVRAM of the CPU possible during voltage dips
  • Communication
    The software controller uses the interfaces of the PC for PROFINET and PROFIBUS:
    • Windows-independent use of PROFINET or PROFIBUS for operating a distributed I/O. Depending on the interface hardware used, the following functions are possible:
      PROFINET IO RT, PROFIenergy, PROFIBUS DP-Master, media redundancy, I-Device, isochronous mode
    • Communication (SIMATIC communication, open user communication) with Windows applications or external devices via the Windows interfaces of the PC
  • Integrated web server;
    Scanning the CPU via the Web server is supported by all CPUs of the S7‑1500 automation system. The CPU Web server offers the following diagnostics options:
    • Image of the CPU with LEDs and the current operating state
    • Readout of the diagnostics buffer entries
    • Query of module status
    • Query of current messages
    • Information on the status of the topology / PROFINET devices
    • Transfer and management of user data into load memory of the CPU
    • User-programmable Web pages for supporting servicing and commissioning of specific machine functions
  • Trace functionality
    The trace function is supported by all CPUs of the S7-1500 automation system. It supports the recording of analog and digital variables for each cycle and their representation as a curve with STEP 7. This is of particular benefit to motion control or closed-loop control applications.
  • Integrated technology:
    • S7-1500 Motion Control;
      PLCopen blocks for programming the motion functionality via PROFINET IO IRT interface.
      This functionality supports rotational speed axes, positioning axes and external sensors.
    • Integrated control functionality;
      Universal PID or 3-step controller with integrated optimization and integrated temperature controller.
  • Integrated system diagnosis:
    The system diagnosis is automatically generated and displayed via a PG/PC, HMI‑device, the Web server or the integral display. System diagnostics are also available when the CPU is in STOP mode.
  • Integrated safety:
    • Know-how protection;
      Algorithms can be reliably protected against unauthorized access and modification.
    • Access protection;
      The extended access protection provides comprehensive protection against unauthorized configuration changes. Various authorization levels are available for assigning separate rights to different user groups.
    • Integrity protection;
      The system protects the data transferred to the CPU against unauthorized tampering. Modified or third-party transmissions of engineering data are safely detected by the CPU and prevented.

Технические данные



Order number

6ES7672-7AC00-0YA0

SIMATIC SOFTWARE CONTROLLER CPU 1507S

General information

 

Product type designation

CPU 1507S

Software version

V1.8

Engineering with

 

  • STEP 7 TIA Portal configurable/integrated as of version

V13 SP1 Update 4

Memory

 

Work memory

 

  • integrated (for program)

5 Mbyte

  • integrated (for data)

20 Mbyte

Load memory

 

  • integrated (on PC mass storage)

300 Mbyte

Backup

 

  • with UPS

Yes; all memory areas declared retentive

  • with non-volatile memory

Yes

CPU processing times

 

for bit operations, typ.

1 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz

for word operations, typ.

2 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz

for fixed point arithmetic, typ.

2 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz

for floating point arithmetic, typ.

2 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz

CPU-blocks

 

Number of blocks (total)

6 000

DB

 

  • Number, max.

6 000; Number range: 1 to 65535

  • Size, max.

16 Mbyte

FB

 

  • Number, max.

5 998; Number range: 1 to 65535

  • Size, max.

512 kbyte

FC

 

  • Number, max.

5 999; Number range: 1 to 65535

  • Size, max.

512 kbyte

OB

 

  • Size, max.

1 048 kbyte

  • Number of free cycle OBs

100

  • Number of time alarm OBs

20

  • Number of delay alarm OBs

20

  • Number of cyclic interrupt OBs

20

  • Number of process alarm OBs

50

  • Number of DPV1 alarm OBs

3

  • Number of isochronous mode OBs

0

  • Number of technology synchronous alarm OBs

2

  • Number of startup OBs

100

  • Number of asynchronous error OBs

4

  • Number of synchronous error OBs

2

  • Number of diagnostic alarm OBs

1

Nesting depth

 

  • per priority class

24

Counters, timers and their retentivity

 

S7 counter

 

  • Number

2 048

IEC counter

 

  • Number

Any (only limited by the main memory)

S7 times

 

  • Number

2 048

IEC timer

 

  • Number

Any (only limited by the main memory)

Data areas and their retentivity

 

Flag

 

  • Number, max.

16 kbyte

Address area

 

I/O address area

 

  • Inputs

32 kbyte

  • Outputs

32 kbyte

Time of day

 

Clock

 

  • Type

Software clock, synchronizable, no battery backup

Interfaces

 

Number of interfaces

3

1. Interface

 

  • Interface type

Onboard PROFINET / IE interface X2 of the SIMATIC IPC, Intel Springville i210T

Interface types

 

  • Number of ports

1

  • RJ 45 (Ethernet)

Yes

  • Transmission rate, max.

100 Mbit/s

  • Industrial Ethernet status LED

Yes

Protocols

 

  • Number of connections via this interface

128

  • PROFINET IO Controller

Yes

  • PROFINET IO Device

Yes

  • SIMATIC communication

Yes

  • Open IE communication

Yes

  • Web server

Yes

PROFINET IO Controller

 

  • Isochronous mode

No

  • IRT

No

  • MRP

No

  • Prioritized startup

Yes; Max. 32 PROFINET devices; if you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205)

  • Number of connectable IO Devices, max.

128

  • Number of connectable IO Devices for RT, max.

128

  • of which in line, max.

128

  • IO Devices changing during operation (partner ports), supported

Yes

  • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • Number of IO Devices per tool, max.

8

  • Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

  • for send cycle of 1 ms

1 ms to 512 ms

PROFINET IO Device

 

  • Isochronous mode

No

  • IRT

No

  • MRP

No

  • Prioritized startup

Yes; If you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205)

  • Shared device

Yes

  • Number of IO Controllers with shared device, max.

2

2. Interface

 

  • Interface type

PROFIBUS with CP 5622, CP 5622 onboard

Interface types

 

  • RS 485

Yes

Protocols

 

  • Number of connections via this interface

44

  • SIMATIC communication

Yes

  • PROFIBUS DP master

Yes

  • PROFIBUS DP slave

No

PROFIBUS DP master

 

  • Equidistance

No

  • Isochronous mode

No

  • Number of connectable DP slaves, max.

64

3. Interface

 

  • Interface type

PROFIBUS with CP 5623

Protocols

 

  • Number of connections via this interface

44

  • SIMATIC communication

Yes

PROFIBUS DP master

 

  • Equidistance

No

  • Isochronous mode

No

  • Number of connectable DP slaves, max.

125

Protocols

 

Number of connections

 

  • Number of connections, max.

128

SIMATIC communication

 

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication, as server

Yes

  • S7 communication, as client

Yes

  • User data per job, max.

64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes

Open IE communication

 

  • TCP/IP

Yes

  • Data length, max.

64 kbyte

  • ISO-on-TCP (RFC1006)

Yes

  • Data length, max.

64 kbyte

  • UDP

Yes

  • Data length, max.

1 472 byte

  • DHCP

No

  • SNMP

Yes

  • DCP

Yes

  • LLDP

Yes

Web server

 

  • HTTP

Yes; Standard and user-defined pages

  • HTTPS

Yes; Standard and user-defined pages

Supported technology objects

 

Motion

Yes

  • Speed-controlled axis

  • Number of speed-controlled axes, max.

60; configurable, up to 60 axes in total (speed-controlled, positioning axis, external encoders) are supported

  • Positioning axis

  • Number of positioning axes, max.

60; configurable, up to 60 axes in total (speed-controlled, positioning axis, external encoders) are supported

  • Synchronized axes (relative gear synchronization)

  • Number of axes, max.

30; Max. number of synchronous axes (requirement: there must be no other motion technology objects created)

  • External encoders

  • Number of external encoders, max.

60; configurable, up to 60 axes in total (speed-controlled, positioning axis, external encoders) are supported

Controller

  • PID_Compact

Yes; Universal PID controller with integrated optimization

  • PID_3Step

Yes; PID controller with integrated optimization for valves

Counting and measuring

  • High-speed counter

Yes

Hardware requirements

 

Hardware required

DE: SIMATIC IPC4x7D, IPC6x7D, IPC8x7D

free hard disk memory for installation, min.

100 Mbyte

free hard disk memory at runtime, min.

400 Mbyte

Work memory, min.

4 Gbyte

Processor

 

  • Single-core processor

No

  • Single-core processor with hyper-threading

No

  • Multi-core processor

Yes

  • Multi-core processor with hyper-threading

Yes

  • occupied cores

1; For multicore processors with activated hyper-threading, one complete physical core is reserved for the CPU 1507S

Configuration

 

Programming

 

Programming language

 

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • CFC

No

  • GRAPH

Yes

Know-how protection

 

  • User program protection

Yes

  • Copy protection

Yes

  • Block protection

Yes

Access protection

 

  • Protection level: Write protection

Yes

  • Protection level: Read/write protection

Yes

  • Protection level: Complete protection

Yes

Dimensions

 

Width

18.2 cm; Packaging

Heigh

Запрос коммерческого предложения

×

    * Поля, обязательные для заполнения.

    Сообщение отправлено

    ×

    В ближайшее время сообщение будет обработано.

    Письмо с номером обращения отправлено на Ваш почтовый ящик.

    Спасибо за то, что выбрали Первый ZIP!

    Что-то пошло не так...

    ×

    К сожалению, наша система расценила Ваше сообщение как спам.

    Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте.

    Приносим извинения за возможные неудобства.