CPU 1507S Siemens
Область применения
The S7-1500 Software Controller CPU 1507S implements the function of a S7-1500 Controller as software on a SIMATIC IPC with Windows. The CPU 1507S is optimized for PC-based control tasks with the IPC427 Microbox PC and the IPC477D Panel PC. In addition, the CPU 1507S supports the IPC627D and IPC827D Box PCs, the IPC677D Panel PC and the IPC647D and IPC847D Rack PCs.
Обзор
- Software Controller for implementing the functions of a SIMATIC S7-1500 Controller on a SIMATIC IPC
- Optimized for PC-based control tasks with the IPC427 Microbox PC and the IPC477D Panel PC.
- Can also be used on IPC627D and IPC827D Box PCs, IPC677D Panel PC, and IPC647D and IPC847D Rack PCs.
Дизайн
The CPU 1507S Software Controller has the following components:
- Windows-independent control core:
- Parallel operation of control and Windows by means of real-time Hypervisor technology
- Windows restart while control is running
- Windows-independent access to bulk memory (CFast, SSD, HDD) for independent storage of configuration and data
- Screen application with functions for
- display of overview information, such as IP address of the integrated interface, station name, plant designation, location identifier, etc.,
- display of diagnostics information
- display of module information
- display of a user-definable logo
- showing display settings
- setting IP addresses
- setting the date and time
- selecting the operating mode
- resetting the CPU to factory settings
- disabling/enabling the display
- enabling protection levels.
- Integrated drivers for IO communication via Ethernet and PROFIBUS interfaces of the PC
- Integrated driver for communication via Windows Ethernet interfaces
- PC-internal communication with WinCC RT Advanced
- PC-internal communication with Windows applications
Функции
The S7-1500 standard CPU - the CPU 1507S - implements the function of a S7-1500 Controller as software on a PC with Windows. This enables a PC to be used for controlling machines or plants.
- Configuring and programming with the STEP 7 engineering tool in the TIA Portal (as from version 13 SP1):
- Programmable according to IEC 61131-3
- Programming languages supported:
- SCL (IL)
- LAD
- FBD
- STL
- GRAPH7 (SFC)
- Innovative real-time system based on virtualization technology;
The real-time system of the integrated S7-1500 software controller enables parallel, independent operation of Windows:- Maximum real-time and deterministic properties
- Operation independent of Windows – supports restart of Windows while the controller is in operation
- Fast restart of the control independently of Windows
- High-speed program execution with several priority-controlled execution levels (cyclic, time-controlled, isochronous with PROFINET or PROFIBUS, event-driven via process and diagnostics alarms)
- Saving of retentive data;
The software controller ensures the security of plant data even when the power fails:- Storage of retentive data on PC hard disk (UPS required)
- Saving of retentive data on the NVRAM of the CPU possible during voltage dips
- Communication
The software controller uses the interfaces of the PC for PROFINET and PROFIBUS:- Windows-independent use of PROFINET or PROFIBUS for operating a distributed I/O. Depending on the interface hardware used, the following functions are possible:
PROFINET IO RT, PROFIenergy, PROFIBUS DP-Master, media redundancy, I-Device, isochronous mode - Communication (SIMATIC communication, open user communication) with Windows applications or external devices via the Windows interfaces of the PC
- Windows-independent use of PROFINET or PROFIBUS for operating a distributed I/O. Depending on the interface hardware used, the following functions are possible:
- Integrated web server;
Scanning the CPU via the Web server is supported by all CPUs of the S7‑1500 automation system. The CPU Web server offers the following diagnostics options:- Image of the CPU with LEDs and the current operating state
- Readout of the diagnostics buffer entries
- Query of module status
- Query of current messages
- Information on the status of the topology / PROFINET devices
- Transfer and management of user data into load memory of the CPU
- User-programmable Web pages for supporting servicing and commissioning of specific machine functions
- Trace functionality
The trace function is supported by all CPUs of the S7-1500 automation system. It supports the recording of analog and digital variables for each cycle and their representation as a curve with STEP 7. This is of particular benefit to motion control or closed-loop control applications. - Integrated technology:
- S7-1500 Motion Control;
PLCopen blocks for programming the motion functionality via PROFINET IO IRT interface.
This functionality supports rotational speed axes, positioning axes and external sensors. - Integrated control functionality;
Universal PID or 3-step controller with integrated optimization and integrated temperature controller.
- S7-1500 Motion Control;
- Integrated system diagnosis:
The system diagnosis is automatically generated and displayed via a PG/PC, HMI‑device, the Web server or the integral display. System diagnostics are also available when the CPU is in STOP mode. - Integrated safety:
- Know-how protection;
Algorithms can be reliably protected against unauthorized access and modification. - Access protection;
The extended access protection provides comprehensive protection against unauthorized configuration changes. Various authorization levels are available for assigning separate rights to different user groups. - Integrity protection;
The system protects the data transferred to the CPU against unauthorized tampering. Modified or third-party transmissions of engineering data are safely detected by the CPU and prevented.
- Know-how protection;
Технические данные
Order number | 6ES7672-7AC00-0YA0 | |
---|---|---|
SIMATIC SOFTWARE CONTROLLER CPU 1507S | ||
General information |
| |
Product type designation | CPU 1507S | |
Software version | V1.8 | |
Engineering with |
| |
| V13 SP1 Update 4 | |
Memory |
| |
Work memory |
| |
| 5 Mbyte | |
| 20 Mbyte | |
Load memory |
| |
| 300 Mbyte | |
Backup |
| |
| Yes; all memory areas declared retentive | |
| Yes | |
CPU processing times |
| |
for bit operations, typ. | 1 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz | |
for word operations, typ. | 2 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz | |
for fixed point arithmetic, typ. | 2 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz | |
for floating point arithmetic, typ. | 2 ns; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz | |
CPU-blocks |
| |
Number of blocks (total) | 6 000 | |
DB |
| |
| 6 000; Number range: 1 to 65535 | |
| 16 Mbyte | |
FB |
| |
| 5 998; Number range: 1 to 65535 | |
| 512 kbyte | |
FC |
| |
| 5 999; Number range: 1 to 65535 | |
| 512 kbyte | |
OB |
| |
| 1 048 kbyte | |
| 100 | |
| 20 | |
| 20 | |
| 20 | |
| 50 | |
| 3 | |
| 0 | |
| 2 | |
| 100 | |
| 4 | |
| 2 | |
| 1 | |
Nesting depth |
| |
| 24 | |
Counters, timers and their retentivity |
| |
S7 counter |
| |
| 2 048 | |
IEC counter |
| |
| Any (only limited by the main memory) | |
S7 times |
| |
| 2 048 | |
IEC timer |
| |
| Any (only limited by the main memory) | |
Data areas and their retentivity |
| |
Flag |
| |
| 16 kbyte | |
Address area |
| |
I/O address area |
| |
| 32 kbyte | |
| 32 kbyte | |
Time of day |
| |
Clock |
| |
| Software clock, synchronizable, no battery backup | |
Interfaces |
| |
Number of interfaces | 3 | |
1. Interface |
| |
| Onboard PROFINET / IE interface X2 of the SIMATIC IPC, Intel Springville i210T | |
Interface types |
| |
| 1 | |
| Yes | |
| 100 Mbit/s | |
| Yes | |
Protocols |
| |
| 128 | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
PROFINET IO Controller |
| |
| No | |
| No | |
| No | |
| Yes; Max. 32 PROFINET devices; if you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205) | |
| 128 | |
| 128 | |
| 128 | |
| Yes | |
| 8 | |
| 8 | |
| The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
| 1 ms to 512 ms | |
PROFINET IO Device |
| |
| No | |
| No | |
| No | |
| Yes; If you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205) | |
| Yes | |
| 2 | |
2. Interface |
| |
| PROFIBUS with CP 5622, CP 5622 onboard | |
Interface types |
| |
| Yes | |
Protocols |
| |
| 44 | |
| Yes | |
| Yes | |
| No | |
PROFIBUS DP master |
| |
| No | |
| No | |
| 64 | |
3. Interface |
| |
| PROFIBUS with CP 5623 | |
Protocols |
| |
| 44 | |
| Yes | |
PROFIBUS DP master |
| |
| No | |
| No | |
| 125 | |
Protocols |
| |
Number of connections |
| |
| 128 | |
SIMATIC communication |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes | |
Open IE communication |
| |
| Yes | |
| 64 kbyte | |
| Yes | |
| 64 kbyte | |
| Yes | |
| 1 472 byte | |
| No | |
| Yes | |
| Yes | |
| Yes | |
Web server |
| |
| Yes; Standard and user-defined pages | |
| Yes; Standard and user-defined pages | |
Supported technology objects |
| |
Motion | Yes | |
| ||
| 60; configurable, up to 60 axes in total (speed-controlled, positioning axis, external encoders) are supported | |
| ||
| 60; configurable, up to 60 axes in total (speed-controlled, positioning axis, external encoders) are supported | |
| ||
| 30; Max. number of synchronous axes (requirement: there must be no other motion technology objects created) | |
| ||
| 60; configurable, up to 60 axes in total (speed-controlled, positioning axis, external encoders) are supported | |
Controller | ||
| Yes; Universal PID controller with integrated optimization | |
| Yes; PID controller with integrated optimization for valves | |
Counting and measuring | ||
| Yes | |
Hardware requirements |
| |
Hardware required | DE: SIMATIC IPC4x7D, IPC6x7D, IPC8x7D | |
free hard disk memory for installation, min. | 100 Mbyte | |
free hard disk memory at runtime, min. | 400 Mbyte | |
Work memory, min. | 4 Gbyte | |
Processor |
| |
| No | |
| No | |
| Yes | |
| Yes | |
| 1; For multicore processors with activated hyper-threading, one complete physical core is reserved for the CPU 1507S | |
Configuration |
| |
Programming |
| |
Programming language |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| No | |
| Yes | |
Know-how protection |
| |
| Yes | |
| Yes | |
| Yes | |
Access protection |
| |
| Yes | |
| Yes | |
| Yes | |
Dimensions |
| |
Width | 18.2 cm; Packaging | |
Heigh Запрос коммерческого предложения× Сообщение отправлено× В ближайшее время сообщение будет обработано. Письмо с номером обращения отправлено на Ваш почтовый ящик. Спасибо за то, что выбрали Первый ZIP! Что-то пошло не так...× К сожалению, наша система расценила Ваше сообщение как спам. Если это произошло по ошибке, пожалуйста, обратитесь к нам по электронной почте. Приносим извинения за возможные неудобства. |