SIMATIC RF380T Siemens

Область применения



Типичные области применения:

  • Грунтовка , катафорез с соответствующим cушильными шкафами;
  • Внешняя область лакокрасочного покрытия с cушильными шкафами;
  • Прачечные с температурой> + 85 ° C

Обзор



Универсальный, компактный накопитель данных  ( ферроэлектрическое ОЗУ 32 Кбайт + 24байта ЭСППЗУ ), в формате (mm) Ø 114 x 83, диапазон температур до +220 °C (цикличный).

Способ действия



Cyclic operation of the transponder at temperatures > 100 °C

At ambient temperatures between +110 °C and +220 °C, care must be taken to ensure that the internal temperature of the SIMATIC RF380T does not exceed the critical threshold of +110 °C. Each heating phase must therefore be followed by a cooling phase. Some limit cycles are listed in the table below.

Heating up

Cooling down

Temperature

Time

Temperature

Time

200 °C

2 h

25 °C

> 8 h

200 °C

1 h

25 °C

> 2 h

190 °C

2 h

25 °C

> 7 h

190 °C

1 h

25 °C

> 1 h 45 min

180 °C

2 h

25 °C

> 5 h 30 min

180 °C

2 h

25 °C

> 4 h 30 min



A temperature calculation tool computes the temperature curve for the heat-proof SIMATIC RF380T transponder (see DVD "RFID Systems Software & Documentation", Order No. 6GT2 080-2AA20).

Чертеж



Технические данные



Order number

6GT2800-5DA00

Product type designation

RF380T transponder

Suitability for operation

RF300

Wireless frequencies

 

Operating frequency Rated value

13.56 MHz

Electrical data

 

Range maximum

160 mm; range is reader dependent: observe http://support.automation.siemens.com/WW/view/en/67384964

Protocol with radio transmission

RF300-specific

Transfer rate with radio transmission maximum

106 kbit/s

Product property multitag-capable

Yes

Product component Backup battery

No

Memory

 

Type of memory

FRAM/EEPROM

Storage capacity of the user memory

32 765 byte

Type of memory organization

UID (fixed code) 4 bytes, user memory 32765 bytes, OTP memory 20 bytes

Number of read cycles at ambient temperature < 40 °C maximum

10 000 000 000

Number of write cycles at ambient temperature < 40 °C maximum

10 000 000 000

Data retention time at ambient temperature < 40 °C not less than

10 y

Property of memory

Block-by-block write protection of the OTP memory

Mechanical data

 

Material

PPS

Color

brown

Mounting distance relating to metal surfaces recommended minimum

0 mm

Permitted ambient conditions

 

Ambient temperature

 

  • during read/write access

-25 ... +110 °C

  • outside the read/write area

-40 ... +220 °C

  • during storage

-40 ... +110 °C

Ambient condition for operation

Cyclic operation at ambient temperature >110 °C

Protection class IP

IP68

Shock resistance

According to DIN EN 60721-3-7 Class 7 M3

Shock acceleration

500 m/s²

Resistance against vibration

200 m/s²

Design, dimensions and weight

 

Height

83 mm

Diameter

114 mm

Net weight

900 g

Mounting type

mount (see accessories)

Product properties, functions, components general

 

Product property

 

  • silicon-free

Yes

  • printable

No

Standards, specifications, approvals

 

Certificate of suitability

Ex: II 3G Ex nC IIB T5

MTBF

1 200 y

Accessories

 

accessories

Skid holder, shrouding cover, universal holder


Технические данные